Errata corrected and clarifications added.
Removed text concerning government requirement of mechanical off
Clarified URL update document, Corrected section references for APIC, SLIT, SRAT in Table 5-5, Update URLs and reformated Table 5-6
Corrected reference to Interrupt Source Override Structure
Corrected name for CPEP table
Corrected reference to SMBus, should be IPMI
Clarified BusCheck and DeviceCheck notifications in Table 5-53
Added link to non-ACPI Plug and Play ID reference document
Added missing _ATT and _GAI names, Corrected page/section references in Table 5-67
Corrected EndTag name value. Was 0x78, correct value is 0x79 Table 6-33
Consumer/Producer bit is ignored (Restored 2.0C change that had been lost)
Clarified use of _GLK (Global Lock) object
Corrected definition of _TSD object
Corrected definition of _PSD object
Corrected table name (CPEP)
Corrected “maximum positive adjustment” value. Was 500%, correct value is 50%, Updated description of example – 300 to 400 lux, Eliminated hardcoded package lengths in examples, Changed “brightness” to “highest ambient light value”
Corrected reference to _IDE, should be _GTM. Corrected table reference
Clarified GPE Block Device Description
Corrected _PLD object examples
Repaired diagram that would not display properly Figure 10-2
Added missing _BCT method to Table 10-3
Clarified that OEM Information field should contain NULL string if not supported in Table 10-4 &Table 10-5
Corrected description of _BTM arguments and return value
Clarified description of _BCT return value
Corrected HID for Power Source device. Was ACPI0003, correct value is ACPI0004
Corrected _PIF example. First package element was a Buffer, should be Integer, Clarified that OEM Information field should contain NULL string if not supported Table 10-10
Corrected description of _SHL method Table 10-11
Clarified _PRL return value, a list of References
Corrected _PMC example. First package element was a Buffer, should be Integer
Clarified that OEM Information field should contain NULL string if not supported Table 10-12
Removed “TODO” note. Updated example
Repaired diagram that would not display properly Figure 15-1
Corrected error conditions from “fatal” to “corrected
Corrected several incorrect section references, Clarified number of Generic Error Data Entry structures is >=1 (not Zero)
Clarified number of Generic Error Data Entry structures is >=1 (not Zero)
Added new section clarifying SCI notification for generic error sources
Added new section describing Firmware First error handling
Clarified purpose of the codes Table 17-17
Added reference to table of COMMAND_STATUS codes Table 17-23
Clarified purpose of the command status codes in Table 17-27 and the error type definitions in Table 17-28
Added _ATT resource descriptor field name
Clarified rules for Buffer vs. Integer return types from a field unit
Corrected section/page reference
|