Fuel quantity indicator
|
Manufacturer
|
ENG
|
Type
|
FQI 678
|
Outside air temperature (OAT) range
|
–30°C–50°C
|
Units
|
Litres
|
Markings
|
None (only the “Empty” value is shown, what has been calibrated to 2 litres, the unusable fuel quantity)
|
Operating range
|
2 litres – 80 litres
|
Accuracy
|
+/– 30%
|
Voltage
|
+10…32 V DC
|
Current
|
0.1 A max
|
Qualification
|
see Table
in addition:
calibration on ground and check in flight for proper operation. Unusable fuel quantity has been calibrated through flight test campaign. See Flight Test Program for details.
|
Manifold pressure indicator
|
Manufacturer
|
ENG
|
Type
|
MPI 456
|
P/N
|
MP-45-00
|
Outside air temperature (OAT) range
|
–30°C–50°C
|
Units
|
Hg In
|
Markings
|
At each 1.0 and 0.5 values
|
Operating range
|
10 – 35 Hg In
|
Accuracy
|
+/– 3%
|
Voltage
|
+10…32 V DC
|
Current
|
0.1 A max
|
Qualification
|
see Table
in addition:
Delivery according to order number with confirmation of accuracy.
Verification in check flight for proper operation
|