169
11.4.6 Combined Flexure and Axial Compression Combined axial and flexure checks are only applied to pile groups with vertical piles.
At this time,
AASHTO (2014) does not have a recommendation to include battered piles. For combined flexure and
compression of vertical piles, AASHTO (2014) requires the factored Structural Limit State to satisfy the following Limit State checks. If
ππ
π’π’
ππ
ππ
< 0.2
ππ
π’π’
2.0 ππ
ππ
+ οΏ½
ππ
π’π’π₯π₯
ππ
πππ₯π₯
+
ππ
π’π’π¦π¦
ππ
πππ¦π¦
οΏ½ β€ 1.0
(Equation 11-47)
ππ
π’π’
ππ
ππ
+
8.0 9.0
οΏ½
ππ
π’π’π₯π₯
ππ
πππ₯π₯
+
ππ
π’π’π¦π¦
ππ
πππ¦π¦
οΏ½ β€ 1.0
(Equation 11-48)
Where:
ππ
u
= Factored axial compressive load (kips).
ππ
r
= Factored compressive resistance (kips).
M
uπ₯π₯
= Factored moment about x-axis (kip-ft).
M
r
π₯π₯
= Factored flexural resistance about x-axis (kip-ft).
M
u
π¦π¦
= Factored moment about y-axis (kip-ft).
M
r
π¦π¦
= Factored flexural resistance about y-axis (kip-ft).