76Upgrade and convert the IP Phone E firmware
5Press the gray arrow at the end of the
Knowledge and SolutionEngine box to obtain the
Search Results.
6From the
Search Results, select the appropriate version of the SIP
Firmware for the IP Phone E, for example,
IP Phone 1140ERelease 0625C1HD26.bin.
7Place the selected firmware on the provisioning server.
—End—Follow the next procedure to convert the UNIStim Firmware to SIP Firmware on the IP Phone 1140E.
Procedure 12Converting UNIStim Firmware to SIP Firmware using TFTPStepAction1Run the TFTP server (for example Tftpd32.exe).
2Place firmware and configuration files in the folder of the TFTP
server (for example 1140e.img F/W file and 1140e.cfg file) that contains the following lines:
Table 14Sample 1140e.cfg configuration file[FW]
DOWNLOAD_MODE AUTO
VERSION 06C25D26.bin
FILENAME 1140e.img
3Configure the IP Phone E Device Settings TFTP IP address to the IP address where your TFTP server is running.
After you are finished the configuration, the IP Phone reboots and sends a request to the TFTP server.
4Select the
Apply&Reset Context-sensitive soft key to save the settings and reset the IP Phone 1140E.
The following messages display
on the IP Phone E as the IPPhone E cycles through the conversion process, one after the other. [FW] Reading. [FW] Writing...
SIP Firmware Release 1.1 for IP Phone E Administration
NN43113-300 Standard May Copyright © 2008, Nortel Networks
Convert UNIStim Firmware to SIP Firmware on the IP Phone 1140E
773. [FW] Finished...
The IP Phone E then boots up with SIP Firmware.
If
the conversion is unsuccessful, seethe chapter "Maintenance and troubleshooting" (page 123)
1. TFTP file transfer takes approximately 15 seconds. File writing takes 2.5 minutes. The IP Phone E displays the message
[FW] writing…
and the blue
Data Waiting LED flashes. After the new SIP
Firmware writing is finished, the blue LED stops flashing and the telephone displays
[FW] finished and then reboots. The first time the SIP Firmware boots, the SIP Firmware performs a Flash File System conversion that takes 2.5 minutes.
—End—SIP Firmware Release 1.1 for IP Phone E Administration
NN43113-300 Standard May Copyright © 2008, Nortel Networks