28 16 00 INTEGRATED INTRUSION DETECTION AND ACCESS CONTROL

SYSTEM COMPONENTS


  1. Head End Equipment

    1. Intrusion Detection/Access Control Panel

      1. DMP - Model No. XR550NL-G

        1. Complete with large enclosure

        2. Complete with Dialer

        3. Quantity of one required.

    2. Mesh Net Radio

      1. AES-Intellinet - Model No. 7058E-P

        1. Quantity of one required

        2. The Mesh Net Radio shall be configured to match the frequency currently being utilized by Irvine Unified School District.

  2. LCD Keypad

    1. DMP – Thinline Series Model No. 7063-W

      1. 32-character alphanumeric LCD display with blue backlit keyboard, self-diagnostic, three 2-button panics, supervised or unsupervised operation, alert sounder, armed and AC LED.

      2. Keypad shall be complete with an integral proximity reader.

      3. The intrusion detection system shall be designed to include a predetermined time delay between entry and alarm. Operation of the keypad shall abort the alarm condition and disable the system until re-armed.

      4. During an alarm condition, the alphanumeric readout on the keypad shall indicate, by room name and number, the location of the alarm and the keyboard turns red.

      5. Quantity as indicated on Plans

  3. Remote Power Supplies

    1. Altronix – Model No. SMP3 or SMP5

      1. Power supply for passive infrared detectors, 12VDC provide one in each building. Provide power supply, terminal cabinet, transformer and battery as required for a complete and operable system.

        1. Terminal cabinet enclosure

          1. DMP – Model No. 350-G or equal

        2. Transformer 120VAC-12VDC

          1. DMP - Model No. 321

        3. Battery

          1. Yuasa – Model No. NP7-12 or equal

  4. Data Bus Splitter/Repeater

    1. DMP – Model No. 710

      1. Expands the typical LX-Bus installation number of devices and the length of the wire.

      2. Quantity as required.

  5. Single Point Zone Expander

    1. DMP - Model No. 711 – Single Point Zone Expander

      1. The single point zone expander module provides a single addressable point and serves as the interface between the 4-wire LX Bus from the control panel and the conventional initiation devices (i.e. motion sensors and door switches).

  6. Multi-Point Zone Expander

    1. DMP – Model No. 714 - four-point Zone Expander

      1. The four-point zone expander module provides four addressable points and serves as the interface between the 4-wire LX Bus from the control panel and the conventional initiation devices (i.e. motion sensors and door switches).

    2. DMP – Model No. 714-8 - Eight-point Zone Expander

      1. The eight-point zone expander module provides eight addressable points and serves as the interface between the 4-wire LX Bus from the control panel and the conventional initiation devices (i.e. motion sensors and door switches).

    3. DMP – Model No. 714-16 - Sixteen-point Zone Expander

      1. The sixteen-point zone expander module provides eight addressable points and serves as the interface between the 4-wire LX Bus from the control panel and the conventional initiation devices (i.e. motion sensors and door switches).

  7. Door Controller Module

    1. DMP – Model No. 734 – Wiegand Interface Module

  8. Motion Sensors – Triple Technology

    1. Bosch – Model No. DS950

      1. Surface wall mount (PIR) passive infrared/microwave motion sensor

      2. 50-foot coverage pattern

      3. Locate motion sensors for optimum coverage per Manufacturer’s recommendation.

      4. Connect to LX Bus via zone expansion module

    2. Bosch – Model No. DS970

      1. Surface wall mount (PIR) passive infrared/microwave motion sensor

      2. 70-foot coverage pattern

      3. Locate motion sensors for optimum coverage per Manufacturer’s recommendation.

      4. Connect to LX Bus via zone expansion module

  9. Magnetic Door Contact

    1. Interlogix – Model No. 1078N

      1. Recessed mounted Steel Door Contact with wire leads, white

    2. Interlogix – Model No. 2505A-L

      1. Surface mounted Wide Gap Door Contact with armored cable leads

  10. Electronic Door Lock

    1. Schlage Model No. AD-300 Series

      1. Provide Schlage PIB300 Panel Interface Board for interface to DMP Wiegand Module.

  11. Siren

    1. ATW Security – Model No. DS-301SET

      1. 25 watt siren in indoor/outdoor stainless steel enclosure.

      2. Sirens shall be provided only if indicated on plans.

  12. Wire/Cable

    1. Interior Device and LX/Keypad Bus Cable

      1. Falcon Wire - Model No. 590422R or equal

        1. 22/4-conductor solid CMR with white jacket

    2. Underground LX Bus/Keypad Bus Cable

      1. Falcon Wire - Model No. 400418H20 or equal

        1. 18/4-conductor stranded FPL with black jacket

        2. Water-blocked cable construction