233
Figure A Example p-y curve for liquefied sand (after Rollins et al. 2005). Note that Equation A is valid only fora pile diameter
D = 324 mm (12 in.
For other pile diameters, the
p values should be corrected. The effect of diameter on the p-y curves developed by Rollins et al. (2005) was studied by Weaver et al. (2001) who proposed a modification factor for correcting Equation A as follows Equation A) Where
D is the diameter of the pile in meters. The value of
p calculated using
Equation A is multiplied by Pdto obtain p-y curves of piles for diameters other than the reference value. However, Equation A may not be appropriate for piles/shafts with diameters significantly smaller than approximately 0.3 minor larger than 1 min ln 𝐷𝐷 + 5.6