_ACx
|
Active Cooling – returns the active cooling policy threshold values.
|
13.4.1
|
421
|
_ADR
|
Address – (1) returns the address of a device on its parent bus.
(2) returns a unique ID for the display output device.
(3) resource descriptor field.
|
7.1.1
B.6.1
18.1.8
|
197
703
548
|
_ALC
|
Ambient Light Chromaticity – returns the ambient light color chromaticity.
|
10.2.4
|
337
|
_ALI
|
Ambient Light Illuminance – returns the ambient light brightness.
|
10.2.2
|
336
|
_ALN
|
Alignment – base alignment, resource descriptor field.
|
18.1.8
|
548
|
_ALP
|
Ambient Light Polling – returns the ambient light sensor polling frequency.
|
10.2.6
|
341
|
_ALR
|
Ambient Light Response – returns the ambient light brightness to display brightness mappings.
|
10.2.5
|
337
|
_ALT
|
Ambient Light Temperature – returns the ambient light color temperature.
|
10.2.3
|
336
|
_ALx
|
Active List – returns a list of active cooling device objects.
|
13.4.2
|
422
|
_ART
|
Active cooling Relationship Table – returns thermal relationship information between platform devices and fan devices.
|
13.4.3
|
422
|
_ASI
|
Address Space Id – resource descriptor field.
|
18.1.8
|
548
|
_ASZ
|
Access Size – resource descriptor field.
|
18.1.8
|
548
|
_ATT
|
Type-Specific Attribute – resource descriptor field.
|
18.1.8
|
548
|
_BAS
|
Base Address – range base address, resource descriptor field.
|
18.1.8
|
548
|
_BBN
|
Bios Bus Number – returns the PCI bus number returned by the BIOS.
|
7.5.5
|
279
|
_BCL
|
Brightness Control Levels – returns a list of supported brightness control levels.
|
B.6.2
|
703
|
_BCM
|
Brightness Control Method – sets the brightness level of the display device.
|
B.6.3
|
703
|
_BCT
|
Battery Charge Time – returns time remaining to complete charging battery.
|
11.2.2.9
|
395
|
_BDN
|
Bios Dock Name – returns the Dock ID returned by the BIOS.
|
7.5.3
|
277
|
_BFS
|
Back From Sleep – inform AML of a wake event.
|
8.3.1
|
296
|
_BIF
|
Battery Information – returns a Control Method Battery information block.
|
11.2.2.1
|
387
|
_BIX
|
Battery Information Extended – returns a Control Method Battery extended information block.
|
11.2.2.2
|
389
|
_BLT
|
Battery Level Threshold – set battery level threshold preferences.
|
10.1.3
|
334
|
_BM
|
Bus Master – resource descriptor field.
|
18.1.8
|
548
|
_BMA
|
Battery Measurement Averaging Interval – Sets battery measurement averaging interval.
|
11.2.2.4
|
392
|
_BMC
|
Battery Maintenance Control – Sets battery maintenance and control features.
|
11.2.2.11
|
397
|
_BMD
|
Battery Maintenance Data – returns battery maintenance, control, and state data.
|
11.2.2.10
|
395
|
_BMS
|
Battery Measurement Sampling Time – Sets the battery measurement sampling time.
|
11.2.2.5
|
392
|
_BQC
|
Brightness Query Current – returns the current display brightness level.
|
B.6.4
|
704
|
_BST
|
Battery Status – returns a Control Method Battery status block.
|
11.2.2.6
|
393
|
_BTM
|
Battery Time – returns the battery runtime.
|
11.2.2.8
|
394
|
_BTP
|
Battery Trip Point – sets a Control Method Battery trip point.
|
11.2.2.7
|
394
|
_CBA
|
Configuration Base Address – sets the CBA for a PCI Express host bridge. See the PCI Firmware Specification, Revision 3.0 at http://pcisig.com
|
|
|
_CDM
|
Clock Domain – returns a logical processor’s clock domain identifier.
|
7.2.1
|
208
|
_CID
|
Compatible ID – returns a device’s Plug and Play Compatible ID list.
|
7.1.2
|
198
|
_CRS
|
Current Resource Settings – returns the current resource settings for a device.
|
7.2.2
|
209
|
_CRT
|
Critical Temperature – returns the shutdown critical temperature.
|
13.4.4
|
425
|
_CSD
|
C State Dependencies – returns a list of C-state dependencies.
|
9.4.2.2
|
317
|
_CST
|
C States – returns a list of supported C-states.
|
9.4.2.1
|
315
|
_DCK
|
Dock – sets docking isolation. Presence indicates device is a docking station.
|
7.5.2
|
277
|
_DCS
|
Display Current Status – returns status of the display output device.
|
B.6.6
|
704
|
_DDC
|
Display Data Current – returns the EDID for the display output device.
|
B.6.5
|
704
|
_DDN
|
Dos Device Name – returns a device logical name.
|
7.1.3
|
198
|
_DEC
|
Decode – device decoding type, resource descriptor field.
|
18.1.8
|
548
|
_DGS
|
Display Graphics State – return the current state of the output device.
|
B.6.7
|
705
|
_DIS
|
Disable – disables a device.
|
7.2.3
|
209
|
_DMA
|
Direct Memory Access – returns a device’s current resources for DMA transactions.
|
7.2.4
|
209
|
_DOD
|
Display Output Devices – enumerate all devices attached to the display adapter.
|
B.4.2
|
697
|
_DOS
|
Disable Output Switching – sets the display output switching mode.
|
B.4.1
|
696
|
_DSM
|
Device Specific Method – executes device-specific functions.
|
10.14.1
|
365
|
_DSS
|
Device Set State – sets the display device state.
|
B.6.8
|
705
|
_DSW
|
Device Sleep Wake – sets the sleep and wake transition states for a device.
|
8.2.1
|
287
|
_DTI
|
Device Temperature Indication – conveys native device temperature to the platform.
|
13.4.5
|
425
|
_Exx
|
Edge GPE – method executed as a result of a general-purpose event.
|
6.6.5.1
|
172
|
_EC
|
Embedded Controller – returns EC offset and query information.
|
14.12
|
461
|
_EDL
|
Eject Device List – returns a list of devices that are dependent on a device (docking).
|
7.3.1
|
241
|
_EJD
|
Ejection Dependent Device – returns the name of dependent (parent) device (docking).
|
7.3.2
|
241
|
_EJx
|
Eject – begin or cancel a device ejection request (docking).
|
7.3.3
|
243
|
_FDE
|
Floppy Disk Enumerate – returns floppy disk configuration information.
|
10.9.1
|
349
|
_FDI
|
Floppy Drive Information – returns a floppy drive information block.
|
10.9.2
|
350
|
_FDM
|
Floppy Drive Mode – sets a floppy drive speed.
|
10.9.3
|
351
|
_FIF
|
Fan Information – returns fan device information.
|
13.3.1.1
|
417
|
_FIX
|
Fixed Register Resource Provider – returns a list of devices that implement FADT register blocks.
|
7.2.5
|
212
|
_FPS
|
Fan Performance States – returns a list of supported fan performance states.
|
13.3.1.2
|
418
|
_FSL
|
Fan Set Level – Control method that sets the fan device’s speed level (performance state).
|
13.3.1.3
|
419
|
_FST
|
Fan Status – returns current status information for a fan device.
|
13.3.1.4
|
420
|
_GAI
|
Get Averaging Interval – returns the power meter averaging interval.
|
11.4.5
|
403
|
_GHL
|
Get Hardware Limit – returns the hardware limit enforced by the power meter.
|
11.4.7
|
404
|
_GL
|
Global Lock – OS-defined Global Lock mutex object.
|
6.7.1
|
191
|
_GLK
|
Global Lock – returns a device’s Global Lock requirement for device access.
|
7.5.7
|
281
|
_GPD
|
Get Post Data – returns the value of the VGA device that will be posted at boot.
|
B.4.4
|
701
|
_GPE
|
General Purpose Events – (1) predefined Scope (\_GPE.)
(2) Returns the SCI interrupt associated with the Embedded Controller.
|
6.3.1
14.11
|
158
460
|
_GRA
|
Granularity – address space granularity, resource descriptor field.
|
18.1.8
|
548
|