Chapter General §101. Definitions [formerly paragraph 1: 001]



Download 6.21 Mb.
Page52/89
Date29.01.2017
Size6.21 Mb.
#11261
1   ...   48   49   50   51   52   53   54   55   ...   89

AUTHORITY NOTE: Promulgated in accordance with R.S. 40:4(A)(7) and R.S. 40:5(2)(3)(7)(9)(16)(17)(20).

HISTORICAL NOTE: Promulgated by the Department of Health and Hospitals, Office of Public Health, LR 38:2816 (November 2012).

§409. Water Conservation

A. Plumbing fixtures and plumbing fixture fittings shall conform to the following requirements.

1. New or replacement water closets, urinals, sink faucets, lavatories or shower heads shall not be installed with a flow rate or flush volume in excess of the maximum specified in Table 409 of this code below, when tested in accordance with the provisions of the applicable ASME Standard listed in Table 407 of this code.



Table 409

Maximum Allowable

Water Usage For Plumbing Fixtures1

Fixture

Max Usage

Lavatory, private

2.2 gpm at 60 psi

Lavatory, public (metering)

0.26 gallons per metering cycle

Lavatory, public (other than metering)

0.5 gpm at 60 psi

Shower Head/Handheld Shower

2.5 gpm at 60 psi

Sink Faucet

2.2 gpm at 60 psi

Urinals

1.0 gal/flushing cycle

Water Closet

1.6 gal/flushing cycle

NOTES:

1. Maximum allowable water usage for plumbing fixtures and fixture fittings not listed in this table should conform to the applicable ANSI or ASME standard listed in Table 407 of this code. Blowout fixtures, vegetable sprayers, clinical sinks, service sinks, hose bibbs and emergency showers sinks shall be exempted from these limitations.


2. Nonwater Urinals. Nonwater urinals shall be listed and comply with the applicable standard(s) referenced in Table 407. Nonwater urinals shall have a barrier liquid sealant to maintain a trap seal. Nonwater urinals shall permit the uninhibited flow of waste through the urinal to the sanitary drainage system. Nonwater urinals shall be cleaned and maintained in accordance with the manufacturer's instructions after installation. Where nonwater urinals are installed they shall have a water distribution line roughed-in above each urinal location to allow for the installation of approved water-use type urinals in the event of a retrofit.

3. Self-closing metering faucets shall be installed on lavatories intended to serve the transient public, such as those in, but not limited to, service stations, train stations, airports, restaurants, and convention halls. Self-closing metering faucets used on lavatories or other hand-washing fixtures shall provide a flow of water for at least 15 seconds without the need to reactivate the faucet. Self-closing faucets which are designed to close immediately upon the release of the handle are prohibited for use on lavatories or other type of hand-washing fixtures.

AUTHORITY NOTE: Promulgated in accordance with R.S. 40:4(A)(7) and R.S. 40:5(2)(3)(7)(9)(16)(17)(20).

HISTORICAL NOTE: Promulgated by the Department of Health and Hospitals, Office of Public Health, LR 38:2816 (November 2012).

§411. Minimum Plumbing Fixtures

A. General. The following general requirements are to be used when applying Table 411 of this Part.

1. Restroom Plumbing Fixtures. Notwithstanding the provisions of LAC 51:I.123.A.2, in new construction, substantial renovation or building additions and in changes of occupancy classification or real property ownership, at least the minimum type(s) of rest room plumbing fixtures provided for in this Section shall be installed, and the minimum number of each type of restroom plumbing fixture shall be in accordance with Table 411 of this Part. The term "substantial renovation" as used in this Paragraph includes, but is not limited to, a renovation/operational change which would trigger the need, pursuant to the requirements of Table 411 of this Part, for additional restroom plumbing fixtures to be installed, even if the occupancy classification itself may not have changed.

a. Exception

i. When only a real property ownership change occurs, restroom plumbing fixture upgrades to meet the minimum plumbing fixture requirements contained in this Section and Table 411 of this Part are not to be blindly enforced if the state health officer/Office of Public Health has assurances that the prior or existing business held a food permit (e.g., grocery store, restaurant, etc.) under LAC 51:XXIII and the prospective new business owner agrees, in writing to the state health officer/Office of Public Health, to operate the business in exactly the same manner as the prior or existing business owner (e.g., parents sell a business to their children who will operate the business in exactly the same manner) and there have been no documented complaints, within the past five years, about:

(a). a lack of toilet room fixtures;

(b). urination in non-restroom fixtures or floor areas within the building; or

(c). urination on the outside of the building or the premises or adjoining lots or areas, etc.

ii. This exception to the normal enforcement procedures (i.e., §411.A.1 of this Code) shall not be applicable when a serious health threat to the public exists.

2. Non-Restroom Plumbing Fixtures. Where the construction of buildings and facilities was approved by the state health officer pursuant to Sanitary Code (LAC 51) requirements then in effect, upgrading of such buildings and facilities to comply with the non-restroom plumbing fixture requirements of Table 411 of this Part shall not be required except where:

a. substantial renovation or building additions are undertaken; or

b. where the occupant or real property ownership thereof or the occupancy classification located therein changes subsequent to the effective date hereof; or

c. where a serious health threat to the public health exists, unless otherwise specifically provided hereinafter.

3. The term "substantial renovation" as used in §411.A.2 of this code includes, but is not limited to, a renovation/operational change which would trigger the need, pursuant to the requirements of Table 411 of this Part, for additional non-restroom plumbing fixtures to be installed, even if the occupant or the occupancy classification itself may not have changed.

4. Except as may be otherwise specifically noted within Table 411 of this Part, the number of occupants of a building shall be determined by the square feet (sq ft) of usable floor space. In determining the usable floor space, the square foot area of permanent structural building components, food service establishment kitchens, toilet rooms, corridors, stairways, vertical shafts and equipment rooms, when necessary for the operation of building utilities only, may be deducted from the total aggregate floor area. The occupant content and the number of required facilities for occupancies other than listed in Table 411 of this Part shall be determined by the plumbing official. Plumbing facilities in the occupancies or tenancies of similar use may be determined by the plumbing official from Table 411 of this Part.

5. In commercial buildings of multiple tenants, common toilet facilities (separate for males and females) for each floor are acceptable in lieu of separate facilities required by this Section only when the applicable building occupant content has common access from within the building. Central facilities shall be installed such that the path of travel to such facilities shall not exceed a distance of 500 feet. The maximum travel distance to the central toilet facilities shall be measured from the main entrance of any store or tenant space. When tenancies, rental units, etc., are to be provided with separate facilities of a partial nature, such facilities are not deductible from the total common facilities required. Tenancies, rental units or other usable areas within a building when separated from the required toilet facilities by walls or partitions without common access openings (i.e., openings through interior walls or partitions that allow access to the toilet facilities) shall be considered independently from the remainder of the building and shall be provided with separate facilities in accordance with this Chapter regardless of the type of occupancy.

6. In self-storage (mini-warehouse) complexes, facilities shall not be required in each building, but shall be located at the office or entrance and such that the plumbing official determines the intent of the code is satisfied (see Paragraphs 7 and 8 in §411.A of this Code below).

7. In applying the schedule of facilities recorded in Table 411 of this Part, consideration must be given to the accessibility of the fixtures. Conformity purely on a numerical basis may not result in an installation suitable to the need of the individual establishment. For example, multi-storied buildings shall be provided with toilet facilities on each floor based upon the population of the floor. If building is a multi-purpose facility (i.e., a retail fuel station and a retail store, or a retail fuel station and a retail store and a restaurant, or a retail store and retail fuel station, etc.), the occupancy which requires the largest number of fixtures shall apply.

8. Every building and each subdivision thereof intended for public use shall be provided with facilities in accordance with this Chapter. Required facilities shall be directly accessible to the public through direct openings or corridors from the area or areas they are intended to serve. Access to the required toilet facilities for customers shall not pass through areas designated as for employee use only such as kitchens, food preparation areas, storage rooms, closets or similar spaces. Toilet facilities accessible only to private offices shall not be counted to determine compliance with this Chapter. Required facilities shall be free and designated by legible signs for each sex. Pay facilities may be installed when in excess of the required minimum facilities.

9. The toilet room entry door shall not be lockable by a user of the facilities when such room contains multiple water closets (or water closet and urinal fixtures) and the fixtures provided therein are required to meet the minimum number of plumbing fixtures required in accordance with Table 411 of this Part.

10. The "Persons (total)" column included in the following Table 411 below is based upon a 50 percent male to 50 percent female ratio.


Table 411

Minimum Plumbing Fixtures

[The figures shown are based upon one fixture being the minimum required for the number of persons indicated or any fraction thereof, i.e., if the calculation yields any fraction (no matter how small), the next whole number greater than the fractional number is the minimum fixture requirement]



Building or Occupancy1

Occupant Content1

Water Closets

(Urinals can be substituted for up to half of the required water closets)

Lavatories2

Bathtubs, Showers and Miscellaneous fixtures

Dwelling or Apt. House

Not Applicable

1 for each dwelling or dwelling unit

1 for each dwelling or dwelling unit

Washing machine connection per unit3. Bathtub or shower – one per dwelling or dwelling unit. Kitchen sink – one per dwelling or dwelling unit

Schools: Licensed Pre-School, Day Care or Nursery20


Maximum Daily Attendance

Children (total)




Fixtures

To be provided in the same proportions as the number of water closets required
Kitchen:
1 in each food preparation and utensil washing area located to permit convenient use by all food and utensil handlers.
Caring for Infants:
1 in or adjacent to each diaper changing area but never to be located in a food preparation/storage or utensil washing area.

Kitchen:

Children (total)

7-15:

3 compartment sink (or approved domestic or commercial dishwashing machine and a 2 compartment sink)12



16 – up:

3 compartment sink (dishwashing machine, if provided, must be a commercial type)12


One laundry tray, service sink, or curbed cleaning facility with floor drain on premises for cleaning of mops/mop water disposal.
Caring for Infants:

One extra laundry tray, service sink, or similar fixture is required to clean and sanitize toilet training potties immediately after each use. Such fixture shall be dedicate solely for this purpose and shall not be in the food preparation/storage, utensil washing, or dining areas.









Age 0 – 4 years













1-20




1













21-40




2













41-80




3













For each additional 40 children over 80, add




1













Age 5 years and above
















Male

Female













1-40

1

1













41-80

1

2













81-120

2

3













121-160

2

4













For each additional 40 females over 160, add




1












For each additional 80 males over 160, add



1









Schools: Elementary & Secondary


Maximum Daily Attendance


Persons (total)



Male

Female

Persons (total)

Male

Female

One drinking fountain for each 3 classrooms, but not less than one each floor







1-50

2

2

1-120

1

1













51-100

3

3

121-240

2

2













101-150

4

4

For each additional 120 persons over 240, add



















151-200

5

5






















For each additional 50 persons over 200, add










1

1












































































1

1















Office4 and Public Buildings


(Applies to educational occupancies above the 12th grade(L))

100 sq ft per person





















Drinking Fountains







Persons (total)

Male

Female

Persons (total)

Male

Female

Persons

Fixtures







1-15

1

1

1-15

1

1

1-100

1







16-35

1

2

16-35

1

2

101-250

2







36-55

2

2

36-60

2

2

251-500

3







56-100

2

3

61-125

2

3

No less than one fixture each floor subject to access.







101-150

3

4

For each additional 120 persons over 125, add
















For each additional 100 persons over 150, add










1

1.5










































































































1

1.5















Common toilet facilities for areas of commercial buildings of multiple tenants5,6,19


(Not applicable to do-it-yourself laundries, beauty shops and similar occupancies where persons must remain to receive personal services)

Use the sq ft per person ratio applicable to the single type occupancy(s) occupying the greatest aggregate floor area (Consider separately each floor area of a divided floor)





















Drinking Fountains







Persons (total)

Male

Female

Persons (total)

Male

Female

Persons

Fixtures







1-50

2

2

1-15

1

1

1-100

1







51-100

3

3

16-35

1

2

101-250

2







101-150

4

4

36-60

2

2

251-500

3







For each additional 100 persons over 150, add







61-125

2

3

501-1000

4
















For each additional 120 persons over 125, add






Not less than one fixture each floor subject to access.


































































1

1.5




1

1.5



Retail


Stores 4,14,16

200 sq ft per person





















Drinking Fountains







Persons (total)

Male

Female

Persons (total)

Male

Female

Persons

Fixtures







1-35

1

1

1-35

1

1

1-100

1







36-55

1

2

36-55

1

2

101-250

2







56-80

2

3

56-80

2

3

251-500

3







81-100

2

4

81-100

2

4

501-1000

4







101-150

2

5

101-150

For each additional 200 persons over 150, add



2

5

Not less than one fixture each floor subject to access.


All Retail Food Markets:

One laundry tray, service sink, or curbed cleaning facility with floor drain on premises for cleaning of mops/mop water disposal.

Retail Food Markets that also processes or packages meat or other food items:

3 compartment sink12









For each additional 200 persons over 150, add
































































1

1.75








































1

1.75

Retail Food Markets that also processes or packages meat or other food items:

1 lavatory in each food processing, packaging, and utensil washing area located to permit convenient use by all food and utensil handlers.




Restaurants/Food Service Establishments4,11,16



30 sq ft per person





















Drinking Fountains17







Persons (total)

Male

Female

Persons (total)

Male

Female

Persons

Fixtures







1-50

1

1

1-150

1

1

1-100

1







51-100

2

2

151-200

2

2

101-250

2







101-200

3

3

201-400

3

3

251-500

3

(If alcoholic beverages are to be served, facilities shall be as required for clubs or lounges-See LAC 51:XXIII.3119.B.2 for further details)




201-300

4

4

For each additional 200 persons over 400, add

















For each additional 200 persons over 300, add

1

2





































Kitchen:






















1

1

3 compartment sink (dishwashing machine, if provided, must be a commercial type)12






































































Kitchen:

1 lavatory in each food preparation and utensil washing area located to permit convenient use by all food and utensil handlers.



Other Fixtures:



















One laundry tray, service sink, or curbed cleaning facility with floor drain on premises for cleaning of mops/mop water disposal.































































Clubs, Lounges, and Restaurants/ Food Service Establishments with Club, or Lounge11,16


30 sq ft per person





















Drinking Fountains17







Persons (total)

Male

Female

Persons (total)

Male

Female

Persons

Fixtures







1-25

1

1

1-150

1

1

1-100

1







26-50

2

2

151-200

2

2

101-250

2







51-100

3

3

201-400

3

3

251-500

3







101-300

4

4










501-1000

4







For each additional 200 persons over 300, add







For each additional 200 persons over 400, add







Bar:

























3 compartment sink (dishwashing machine, if provided, must be a commercial type)12





































1

2




1

1



















Bar:

1 lavatory in each drink preparation area and utensil washing area located to permit convenient use by all drink and utensil handlers.



Other Fixtures:



















One laundry tray, service sink, or curbed cleaning facility with floor drain on premises for cleaning of mops/mop water disposal.

Do it yourself Laundries4

50 sq ft per person

Persons (total)

Male

Female

Persons (total)

Male

Female

One drinking fountain and one service sink.







1-50

1

1

1-100

1

1










51-100

1

2

101-200

2

2







Beauty Shops, Barber shops, nail Salons, and Tanning Facilities4

50 sq ft per person

Persons (total)

Male

Female

Persons (total)

Male

Female

One drinking fountain and one service sink or other utility sink.







1-35

1

1

1-75

1

1










36-75

1

2















Heavy manufacturing7, warehouses8, foundries, and similar establishments9,10


Occupant content per shift, substantiated by owner. Also see §411.B.2 of this code




















One drinking fountain for each 75 persons. One shower for each 15 persons exposed to excessive heat or to skin contamination with poisonous, infectious, or irritating material.










Persons (total)

Male

Female

Persons (total)

Male

Female










1-10

1

1

1-15

1

1










11-25

2

1

16-35

2

1










26-50

3

1

36-60

3

1










51-75

4

1

61-90

4

1










76-100

5

1

91-125

5

1










For each additional 60 persons over 100, add







For each additional 100 persons over 125, add




























1

0.1













1

0.1

Where there is exposure to skin contamination with poisonous, infectious, or irritating materials, provide 1 lavatory for each 15 persons.


























Light manufacturing7, Light Warehousing8, and workshops, etc.9,10


Occupant content per shift, substantiated by owner. Also see §411.B.2 of this code




















One drinking fountain for each 75 persons. One shower for each 15 persons exposed to excessive heat or to skin contamination with poisonous, infectious, or irritating material.









Persons (total)

Male

Female

Persons (total)

Male

Female










1-25

1

1

1-35

1

1










26-75

2

2

36-100

2

2










76-100

3

3

101-200

3

3










For each additional 60 persons over 100, add







For each additional 100 persons over 200, add














































1

1




1

1






















Where there is exposure to skin contamination with poisonous, infectious, or irritating materials, provide 1 lavatory for each 15 persons







Dormitories

(For exclusively male or female dorms, the fixtures provided shall be double the amount required for the particular gender in a co-ed dorm)



50 sq ft per person (calculated on sleeping area only)

Persons (total)

Male

Female

Persons (total)

Male

Female

One drinking fountain for each 75 persons. One shower or bathtub for each 8 persons, over 150 persons add 1 shower or bathtub for each additional 20 persons. One laundry tray or washing machine for each 50 persons. Service sinks, 1 for each 100 persons.







1-10

1

1

1-12

1

1










11-30

1

2

13-20

2

2










31-100

3

4

For each additional 30 persons over 20, add
















For each additional 50 persons over 100, add





































1

1













1

1







































Places of Public Assembly without seats and Waiting Rooms at Transportation Terminals and Stations


70 sq ft per person (calculated from assembly area.) Other areas considered separately (see Office or Public Buildings).





















Drinking Fountains







Persons (total)

Male

Female

Persons (total)

Male

Female

Persons

Fixtures







1-50

2

2

1-200

1

1

1-100

1







51-100

3

3

201-400

2

2

101-350

2







101-200

4

4

401-750

3

3













201-400

5

5

Over 750 persons, lavatories for each sex shall be required at a number equal to not less than 1/2 of total of required water closets and urinals.



Over 350 add one fixture for each 400.







For each additional 250 persons over 400, add
































































1

2






Theaters, Auditoriums, Stadiums15, Arenas15, and Gymnasiums


Use the number of seats as basis (For pew or bench type seating, each 18 inches of pew or bench shall equate to one person)





















Drinking Fountains







Persons (total)

Male

Female

Persons (total)

Male

Female

Persons

Fixtures







1-50

2

2

1-200

1

1

1-100

1







51-100

3

3

201-400

2

2

101-350

2







101-200

4

4

401-750

3

3













201-400

5

5

Over 750 persons, lavatories for each sex shall be required at a number equal to not less than 1/2 of total of required water closets and urinals.



Over 350 add one fixture for each 400.







For each additional 250 persons over 400, add
































































1

2






Churches, Mosques, Synagogues, Temples, and other places of Worship


Use the number of seats as basis (For pew or bench type seating, each 18 inches of pew or bench shall equate to one person)





















Drinking Fountains







Persons (total)

Male

Female

Persons (total)

Male

Female

Persons

Fixtures







1-70

1

1

1-200

1

1

1-100

1







71-150

2

2

201-400

2

2

101-350

2







151-500

3

3

401-750

3

3













For each additional 500 persons over 500, add






Over 750 persons, lavatories for each sex shall be required at a number equal to not less than 1/2 of total of required water closets and urinals.



Over 350 add one fixture for each 400.









































































1

1






Retail Fuel Stations (Along an Interstate highway when the station property is located within ½ mile of the nearest toe18 of the exit/entrance ramp)16


Use the number of Fueling Points13 as the basis





















Drinking Fountains







Fueling Points

Male

Female

Fueling Points

Male

Female

Fueling Points

Fixtures







1-8

1

1

1-12

1

1

1-12

1







9-12

2

2

13 or more

1

2

13 or more

2







13 or more

2

3















Retail Fuel Stations not meeting above criteria16


Use the number of Fueling Points13 as the initial basis





















Drinking Fountains







Fueling Points

Male

Female

Fueling Points

Male

Female

Fueling Points

Fixtures







1 or more

1

1

1 or more

1

1

1 or more

1






























Other Miscellaneous Buildings or Occupancies21
























































































Download 6.21 Mb.

Share with your friends:
1   ...   48   49   50   51   52   53   54   55   ...   89




The database is protected by copyright ©ininet.org 2024
send message

    Main page