ANSI A21.4-2008*, Cement-Mortar Lining for Ductile-Iron Pipe and Fittings for Water (same as AWWA C104)
|
Table 303
|
ANSI A21.10-2008 (R2012)*, Ductile-Iron and Gray-Iron Fittings (same as AWWA C110)
|
Table 603
|
ANSI A21.11-2006*, Rubber Gasket Joints for Ductile-Iron Pressure Pipe and Fittings (same as AWWA C111)
|
709.G
|
ANSI A21.51-2009*, Ductile-Iron Pipe, Centrifugally Cast (same as AWWA C151)
|
Table 603
|
ANSI A21.53 -2006*, Ductile-Iron Compact Fittings for Water Service (same as AWWA C153) |
Table 603
|
ANSI A117.1-2003*, Standard for Accessible and Usable Buildings and Facilities
|
415.I.1, 415.I.3
|
ANSI A118.10-2008, Load Bearing, Bonded, Waterproof Membranes for Thin-Set Ceramic Tile and Dimension Stone Installation
|
Table 303, 303.G.7.c
|
ANSI B16.32-1992, Cast Copper Alloy Solder Joint Fittings for Sovent Drainage Systems
|
Table 703
|
ANSI B16.43-1982, Wrought Copper and Copper Alloy Solder Joint Fittings for Sovent Drainage Systems
|
Table 703
|
ANSI B31.1-55, Code for Pressure Piping
|
621.D
|
ANSI Z4.1-1986 (R2005)*, Sanitation in Places of Employment, Minimum Requirement for
|
405.C, Table 411 - Footnote 13
|
ANSI Z21.10.1-2009, Gas Water Heaters, Volume 1, Storage Water Heaters with Input Ratings of 75,000 Btu per Hour or Less (same as CSA 4.1)
|
503.B
|
ANSI Z21.10.3-2011, Gas Water Heaters Volume III, Storage, with Input Ratings Above 75,000 Btu per Hour, circulating and instantaneous (same as CSA 4.3)
|
503.B
|
ANSI Z21.22-1999(R2008)*, Relief Valves for Hot Water Supply Systems (same as CSA 4.4M)
|
501.F.1, 511.A.2, 511.G
|
ANSI Z124.1.2-2005*, Plastic Bathtub and Shower Units
|
Table 407, Table 415.I
|
ANSI Z124.3-2005*, Plastic Lavatories
|
Table 407
|
ANSI Z124.4-2006*, Plastic Water Closet Bowls and Tanks
|
Table 407
|
ANSI Z535.1-2006 (R2011), American National Standard for Safety Colors
|
607.A
|
APSP 2-1999*, Public Spas
|
Table 415.K
|
APSP 3-1999*, Permanently Installed Residential Spas
|
Table 415.K
|
APSP 6-1999*, Residential Portable Spas
|
Table 415.K
|
APSP 16-2011*, Standard Suction Fittings for Use in Swimming Pools, Wading Pools, Spas, and Hot Tubs (same as ASME A112.19.8)
|
415.K.2, 415.O.6
|
ARI 1010-2002, Drinking Fountains and Self-Contained, Mechanically-Refrigerated Drinking-Water Coolers
|
415.C.1
|
ASME Boiler and Pressure Vessel Code, Section IX, Welding and Brazing Qualifications, 1998 Edition
|
315.D
|
ASME A13.1-2007*, Scheme for the Identification of Piping Systems
|
607.A.1, 607.A.3, 607.B
|
ASME A112.1.2-2004*, Air Gaps in Plumbing Systems
|
415.C.1, 415.C.2, 609.A.1, Table 609, 609.C.7, 609.F.2
|
ASME A112.3.1-2007*, Stainless Steel Drainage Systems for Sanitary DWV, Storm, and Vacuum Applications, Above- and Below Ground
|
703.C.1, 703.D, Table 703
|
ASME A112.3.4-2000*, Macerating Toilet Systems and Related Components
|
Table 407, 729.C
|
ASME A112.4.1-2009, Water Heater Relief Valve Drain Tubes
|
Table 511
|
ASME A112.6.1M-1997 (R2002)*, Supports for Off-the-Floor Plumbing Fixtures for Public Use (Floor -Affixed)
|
Table 303
|
ASME A112.6.2-2000*, Framing-Affixed Supports for Off-the-Floor Water Closets with Concealed Tanks
|
Table 303
|
ASME A112.6.3-2001*, Floor Drains
|
Table 303
|
ASME A112.6.4-2003 (R2008)*, Roof, Deck, and Balcony Drains (dual roof drain assemblies wherein the inlets of both are enclosed in the same strainer are prohibited)
|
Table 303
|
ASME A112.14.1-2003 (R2008)*, Backwater Valves
|
705.G.2
|
ASME A112.14.3-2000 (R2004)*, Grease Interceptors
|
1005.N.1, 1005.N.5.a, 1005.N.6.a
|
ASME A112.18.1-2005*, Plumbing Fixture Fittings (same as CSA B125.1)
|
Table 407
|
ASME A112.18.2-2011, Plumbing Waste Fittings (Same as CSA B125.2
|
Table 407
|
ASME A112.18.3-2002*, Requirements for Backflow Protection Devices and Systems in Plumbing Fixture Fittings
|
Table 407, 609.C.7
|
ASME A112.18.6-2009, Flexible Water Connectors (same as CSA B125.6)
|
Table 407, 509.B
|
ASME A112.19.1-2008*, Enameled Cast Iron and Enameled Steel Plumbing Fixtures (same as CSA B45.2)
|
Table 407, 415.C.1
|
ASME A112.19.2-2008*, Ceramic Plumbing Fixtures (same as CSA B45.1)
|
Table 407, 415.C.1
|
ASME A112.19.3-2008*, Stainless Steel Plumbing Fixtures (same as CSA B45.4)
|
Table 407
|
ASME A112.19.4M-1994 (R2008)*, Porcelain Enameled Formed Plumbing Fixtures
|
Table 407
|
ASME A112.19.5-2011, Trim for Water-Closet Bowls, Tanks and Urinals (same as CSA B45.15)
|
Table 407
|
ASME A112.19.6-1995*, Hydraulic Performance Requirements for Water Closets & Urinals
|
Table 407
|
ASME A112.19.7-2012, Hydromassage Bathtub Systems (same as CSA B45.10)
|
415.O.4, 415.O.5
|
ASME A112.19.8-2007*, Suction Fittings for Use in Swimming Pools, Wading Pools, Spas, and Hot Tubs (same as APSP 16)
|
415.K.2, 415.O.6
|
ASME A112.19.9M-1991 (R2002)*, Non-vitreous Ceramic Plumbing Fixtures
|
Table 407
|
ASME A112.19.19-2006, Vitreous China Nonwater Urinals
|
Table 407
|
ASME A112.36.2M-1991 (R2002)*, Cleanouts
|
Table 303
|
ASME B1.20.1-1983 (R2006)*, Pipe Threads, General Purpose (Inch)
|
313.B
|
ASME B16.3-2011, Malleable Iron Threaded Fittings, Classes 150 and 300
|
Table 603
|
ASME B16.4-2011, Gray Iron Threaded Fittings, Classes 125 and 250
|
Table 603
|
ASME B16.5-2009, Pipe Flanges and Flanged Fittings
|
Table 603
|
ASME B16.12-2009, Cast-Iron Threaded Drainage Fittings
|
Table 703
|
ASME B16.15-2011, Cast Bronze Threaded Fittings, Classes 125 and 250
|
Table 603
|
ASME B16.18-2001, Cast Copper Alloy Solder Joint Pressure Fittings
|
Table 603
|
ASME B16.22-2001*, Wrought Copper and Copper Alloy Solder Joint Pressure Fittings
|
Table 603
|
ASME B16.23-2011, Cast Copper Alloy Solder Joint Drainage Fittings-DWV
|
Table 703
|
ASME B16.24-2011, Cast Copper Alloy Pipe Flanges: Class 150. 300, 400, 600, 900, 1500, and 2500
|
Table 603
|
ASME B16.26-2006*, Cast Copper Alloy Fittings for Flared Copper Tubes
|
Table 603
|
ASME B 16.29-2007*, Wrought Copper and Wrought Copper Alloy Solder Joint Drainage Fittings-DWV
|
Table 703
|
ASME B16.34-2009, Valves-Flanged Threaded, and Welding End
|
Table 603
|
ASME B16.45-1998 (R2006)*, Cast Iron Fittings for Sovent Drainage Systems
|
1811.E.3
|
ASSE 1001-2008*, Performance Requirements for Atmospheric-Type Vacuum Breakers
|
Table 609
|
ASSE 1002-2008*, Anti-Siphon Fill Valves for Water Closet Tanks
|
Table 609
|
ASSE 1003-2009*, Performance Requirements for Water Pressure Reducing Valves for Domestic Water Distribution Systems
|
611.J.1, 611.J.6
|
ASSE 1010-2004*, Performance Requirements for Water Hammer Arresters
|
Table 407, 611.I.1
|
ASSE 1011-2004*, Performance Requirements for Hose Connection Vacuum Breakers
|
Table 609
|
ASSE 1012-2009*, Performance Requirements for Backflow Preventers with Intermediate Atmospheric Vent
|
Table 609, 609.C.5
|
ASSE 1013-2011*, Performance Requirements for Reduced Pressure Principle Backflow Preventers and Reduced Pressure Principle Fire Protection Backflow Preventers
|
Table 609, 609.C.5
|
ASSE 1014-2005, Performance Requirements for Backflow Prevention Devices for Hand Held Showers
|
Table 303
|
ASSE 1015-2011*, Performance Requirements for Double Check Backflow Prevention Assemblies and Double Check Fire Protection Backflow Prevention Assemblies
|
Table 609
|
ASSE 1016-2011*, Performance Requirements for Automatic Compensating Valves for Individual Showers and Tub/Shower Combinations
|
Table 623, 623.A.1, 623.A.2
|
ASSE 1017-2009*, Performance Requirements for Temperature Actuated Mixing Valves for Hot Water Distribution Systems
|
623.A, Table 623
|
ASSE 1018-2001*, Performance Requirements for Trap Seal Primer Valves - Potable Water Supplied
|
415.E.4.a, 625.D.1
|
ASSE 1019-2011*, Performance Requirements for Vacuum Breaker Wall Hydrants, Freeze Resistant, Automatic Draining
|
Table 303, Table 609
|
ASSE 1020-2004*, Pressure Vacuum Breaker Assembly
|
Table 609
|
ASSE 1022-2003*, Backflow Preventers for Beverage Dispensing Equipment
|
Table 609
|
ASSE 1035-2008*, Performance Requirements for Laboratory Faucet Backflow Preventers
|
Table 303, Table 609
|
ASSE 1037-1990, Performance Requirements for Pressurized Flushing Devices (Flushometers) for Plumbing Fixtures
|
Table 303
|
ASSE 1043-1992, Performance Standard for Cast Iron Sovent Sanitary Drainage Systems
|
1811.E.3
|
ASSE 1044-2001*, Performance Requirements for Trap Seal Primer Devices, Drainage Types and Electronic Types
|
415.E.4
|
ASSE 1047-2011*, Performance Requirements for Reduced Pressure Detector Fire Protection Backflow Prevention Assemblies
|
Table 609
|
ASSE 1048-2011*, Performance Requirements for Double Check Detector Fire Protection Backflow Prevention Assemblies
|
Table 609
|
ASSE 1052-2004*, Performance Requirements for Hose Connection Backflow Preventers
|
Table 609
|
ASSE 1056-2001*, Performance Requirements for Spill Resistant Vacuum Breakers
|
Table 609
|
ASSE 1061-2011*, Performance Requirements for Push-Fit Fittings (for use on PEX tubing complying with ASTM F 876 or F877, type K and L hard drawn and annealed copper tubing complying with ASTM B 88, and CPVC tubing complying with ASTM D 2846)
|
Table 603
|
ASSE 1069-2005*, Performance Requirements for Automatic Temperature Control Mixing Valves
|
Table 623, 623.A.1
|
ASSE 1070-2004*, Performance Requirements for Water Temperature Limiting Devices
|
Table 623, 623.B, 623.C
|
ASSE 1072-2007, Performance Requirements for Barrier Type Floor Drain Trap Seal Protection Devices
|
415.E.4
|
ASSE Series 5000-2009*, Cross-Connection Control Professional Qualifications Standard
|
319.F, Table 609, 609.F
|
ASSE 5110-2009, Backflow Prevention Assembly Tester Professional Qualifications Standard (part of ASSE Series 5000, Cross-Connection Control Professional Qualifications Standard)
|
609.F.9
|
ASSE 5120-2009, Backflow Prevention Assembly Surveyor Professional Qualifications Standard (part of ASSE Series 5000, Cross-Connection Control Professional Qualifications Standard)
|
607.C
|
ASSE 5130-2009, Backflow Prevention Assembly Repairer (part of ASSE Series 5000, Cross-Connection Control Professional Qualifications Standard)
|
609.F.9
|
ASTM A48/A48M-2003 (R2008), Standard Specification for Gray Iron Castings
|
Table 703, 717.G
|
ASTM A53/A53M-2012, Standard Specification for Pipe, Steel, Black and Hot-Dipped, Zinc-Coated Welded and Seamless
|
Table 603
|
ASTM A74-2009, Standard Specification for Cast Iron Soil Pipe and Fittings
|
303.G.6.a, Table 703
|
ASTM A126-2004 (R2009), Standard Specification for Gray Iron Castings for Valves, Flanges, and Pipe Fittings
|
Table 603, Table 619.D
|
ASTM A197/A197M-2000 (R2011), Standard Specification for Cupola Malleable Iron
|
Table 603
|
ASTM A2692010, Standard Specification for Seamless and Welded Austenitic Stainless Steel Tubing for General Service
|
Table 603
|
ASTM A312/A312M-2012, Standard Specification for Seamless, Welded, and Heavily Cold Worked Austenitic Stainless Steel Pipes |
Table 603
|
ASTM A377-2003 (R2008)e1, Standard Index of Specifications for Ductile-Iron Pressure Pipe
|
Table 603
|
ASTM A518/A518M-1999 (R2008), Standard Specification for Corrosion-Resistant High-Silicon Iron Castings |
Table 703, 703.F
|
ASTM A653/ A653M-2011, Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process
|
Table 303
|
ASTM A733-2003 (R2009)e1, Standard Specification for Welded and Seamless Carbon Steel and Austenitic Stainless Steel Pipe Nipples |
Table 603
|
ASTM A746-2009, Standard Specification for Ductile Iron Gravity Sewer Pipe
|
Table 703
|
ASTM A778-2001 (R2009)e1, Standard Specification for Welded, Unannealed Austenitic Stainless Steel Tubular Products |
Table 603
|
ASTM A865/A865M-2006, Standard Specification for Threaded Couplings, Steel, Black and Zinc-Coated (Galvanized) Welded and Seamless, for Use in Steel Pipe Joints
|
Table 603
|
ASTM A888-2011, Standard Specification for Hubless Cast Iron Soil Pipe and Fittings for Sanitary and Storm Drain, Waste, and Vent Piping Applications
|
Table 703
|
ASTM B32-2008, Standard Specification for Solder Metal
|
Table 303
|
ASTM B42-2010, Standard Specification for Seamless Copper Pipe, Standard Sizes
|
Table 603
|
ASTM B43-2009, Standard Specification for Seamless Red Brass Pipe, Standard Sizes
|
Table 603
|
ASTM B75/B75M-2011, Standard Specification for Seamless Copper Tube
|
Table 603
|
ASTM B88-2009, Standard Specification for Seamless Copper Water Tube
|
513.F.1, Table 603, 613.A.1, 619.A.2, 619.B
|
ASTM B135-2008a, Standard Specification for Seamless Brass Tube
|
Table 603
|
ASTM B135-2010, Standard Specification for Seamless Brass Tube
|
Table 603
|
ASTM B152/B152M-2009, Standard Specification for Copper Sheet, Strip, Plate and Rolled Bar
|
Table 303
|
ASTM B248-2007, Standard Specification for General Requirements for Wrought Copper and Copper- Alloy Plate, Sheet, Strip, and Rolled Bar
|
Table 303
|
ASTM B248M-2007, Standard Specification for General Requirements for Wrought Copper and Copper- Alloy Plate, Sheet, Strip, and Rolled Bar Metric
|
Table 303
|
ASTM B251-2010, Standard Specification for General Requirements for Wrought Seamless Copper and Copper-Alloy Tube
|
Table 603
|
ASTM B251M-2010, Standard Specification for General Requirements for Wrought Seamless Copper and Copper-Alloy Tube Metric
|
Table 603
|
ASTM B302-2007, Standard Specification for Threadless Copper Pipe, Standard Sizes
|
Table 603
|
ASTM B306-2009, Standard Specification for Copper Drainage Tube (DWV)
|
Table 703
|