S-52 Appendix 2 - IHO
S-52 Appendix 2 - IHO
[general]
Heading
Luminance=cd units for luminance measurements – either candelas/m^2 (cd) or foot-lamberts (ft-L) coord=xy specifies the colour coordinate system – must be one of x,y or u,v. The colour specifications for the
PRESLIB are all in x,y coordinates. count count of luminance values in the DAC input table Threshold C threshold for flagging errors
Output_format=%s;%s;%6.4f;%6.4f;
%6. 3f;%3d;%3d;%3d;%f; s output format string. This is a standard C printf() format string. The fields being formatted are Token Colour,
x,y,L values
R,G,B values C error marker error marker symbol for out of spec. colours - i.e. colours that can't be achieved on the monitor using initial calibration. error marker symbol for out of spec. Colours - colours that are beyond the C threshold of 10 from their ideal