Specific gravity correction is negligible for water below Fuse S = 1.0). Use actual specific gravity S of other liquids at actual flow temperature. Use the following equation for fluids with viscosity correction factor. Use actual specific gravity S for fluids at actual flow temperature. Where,
• K = Viscosity correction factor for fluids Estimating diameter of pipe Another important piece of information about sizing and specifications is what diameter pipe
maybe used with a certain flow, seen in the following equation Where
• d = diameter of pipe (ft)
•
Q max = maximum flow through the valve (
ft3
/
s)
• v = velocity of flow (ft./s)
Share with your friends: