Page | 21/60 | Date | 16.12.2020 | Size | 1.08 Mb. | | #54495 |
| 155646687-Oil-Tanker-Construction-Rules - Drive motors are to be installed outside the cargo area. Exceptions are steam-driven machines where the steam temperature does not exceed 220 °C.
- Hydraulic cargo pump driving machinery (e.g. for submerged pumps) may be installed inside the cargo area.
- Cargo line systems shall be permanently installed and completely separated from other piping systems.
- In general they may not extend beyond the cargo area.
- Cargo lines are to be so installed that any remaining cargo can be drained into the cargo tanks.
- Filling pipes for cargo tanks are to extend down to the bottom of the tank.