AIS 156
AIS 156
Protection against Water Effects
The test as per 5.5.1, 5.5.2 and 5.5.3 shall be performed. After each exposure vehicles still wet, the vehicle shall then comply with the isolation resistance test with at least 100 V of nominal voltage, but keeping the power equipment


AIS 156 Draft Db connected to the REESS (main switch closed, and before water test isolation resistance with at least 500 V of nominal voltage. These tests shall not apply to vehicles having chassis connected electrical circuits where the maximum voltage between any live part and the electrical chassis or any exposed conductive part does not exceed VAC (rms) or 60 V DC.