22 The approval of a REESS tested according to this paragraph shall be limited to approvals fora specific vehicle type.
6.5.2. Component based test The test shall be conducted in accordance with Annex E in due consideration of paragraph 3.2.2. of Annex E.
6.5.3. Acceptance criteria
6.5.3.1. During the test, the tested-device shall exhibit no evidence of explosion.
6.6. External short circuit
protection 6.6.1. The test shall be conducted in accordance with Annex 8F
of this Standard.
6.6.2. Acceptance criteria
6.6.2.1. During the test there shall be no evidence of a) Electrolyte leakage b) Rupture (applicable to high voltage REESS(s) only c) Fired) Explosion. Evidence of electrolyte leakage shall be verified by visual inspection without disassembling any part of the tested-device.
6.6.2.2. Fora high voltage REESS, the isolation resistance measured after the test in accordance with Annex B to this Standard shall not be less than 100 V.
6.7.
Overcharge protection 6.7.1. The test shall be conducted in accordance with Annex 8G
to this Standard.
6.7.2. Acceptance criteria
6.7.2.1. During the test there shall be no evidence of a) Electrolyte leakage b) Rupture (applicable to high voltage REESS(s) only c) Fired) Explosion. Evidence of electrolyte leakage shall be verified by visual inspection without disassembling any part of the tested-device.
6.7.2.2. Fora high voltage REESS, the isolation resistance measured after the test in accordance with Annex B to this Standard shall not be less than 100 V.
6.8.
Over-discharge protection
6.8.1. The test shall be conducted in accordance with Annex H to this Standard.
6.8.2. Acceptance criteria
6.8.2.1. During the test there shall be no evidence of a) Electrolyte leakage b) Rupture (applicable to high voltage REESS(s) only c) Fire