c)Applicants
Ethyl Asia Pacific Company
PO Box 285
North Sydney NSW 2059
Wynn’s Australia Pty Ltd
PO Box 6096
French’s Forest Delivery Centre NSW 1640
Nulon Products Australia Pty Ltd
114 Narabang Way
Belrose NSW 2085
d.1Chemical identity
-
Chemical Name:
|
Manganese tricarbonyl [(1,2,3,4,5-eta)-1-methyl-2,4-cyclopentadien-1-yl]-
|
CAS No.:
|
12108-13-3
|
EINECS No.:
|
235-166-5
|
Synonyms:
|
MMT, Methylcyclopentadienyl manganese tricarbonyl, Methylcymantrene
|
Trade Names:
|
AK-33X, Antiknock-33, CI-2, Combustion Improver-2.
|
Molecular Formula:
|
C9H7MnO3
|
Structural Formula:
|
|
Molecular Weight:
|
218
|
The Ethyl Asia Pacific Company markets two MMT-containing products. HiTEC 3062 contains 62% MMT w/w in a mixed aromatic and aliphatic solvent and HiTEC 3000 contains neat MMT. At the time of writing, HiTEC 3000 is not being imported to Australia.
Wynn’s Australia Pty Ltd markets two MMT-containing products. Spitfire Octane Boost and Race Formula Octane Boost both contain < 5% w/w MMT in petroleum distillate.
Nulon Products Australia Pty Ltd markets three MMT-containing products. Octane Boost and Clean and Total Fuel System Cleaner both contain < 5% w/w MMT whilst Pro Strength Octane Booster contains < 10% w/w MMT, all in petroleum distillate.
e)Physical and Chemical Properties e.1Physical state
MMT is a dark orange or yellow liquid with a faintly pleasant or herbaceous odour (Lewis 1996).
-
Property
|
Value
|
Reference
|
Boiling point
|
231.67oC
|
ACGIH, 1991
|
Melting point
|
2.22oC
|
Ethyl Submission
|
Density at 20oC
|
1390 kg/m3
|
ACGIH, 1991
|
Water solubility at 25oC
|
0.029 g/L
|
Ethyl Submission
|
Vapour pressure at 100oC
|
1.24 kPa
|
Zenz , 1988
Ethyl Submission
|
at 20oC
|
0.01 kPa
|
Henry’s law constant
|
<10-9 Pa m3/mol
|
Ethyl Submission
|
Partition coefficient (log Pow)
|
3.4
|
Ethyl Submission
|
Autoignition temperature
|
257oC
|
Ethyl Submission
|
Flammability Limits
|
Lower: 0.3% at 153oC
Upper: 26% at 175oC
|
Ethyl Submission
|
Flash point (closed cup)
|
96oC
|
Zenz, 1988
| e.3Chemical properties
Solubility: MMT is miscible in most hydrocarbon solvents (Kirk-Othmer 1967).
Stability: MMT decomposes when exposed to light (Kaufman et al., 1961).
Polymerisation: MMT will not undergo hazardous polymerisation.
e.4Conversion factors (at 25oC)
1 mg/m3 = 8.93 ppm 1 ppm = 0.11 mg/m3
f)Methods of Detection and
Analysis f.1Identification
The detection and determination of MMT is usually achieved by using chromatography together with spectrophotometry. In addition, a number of methods have been described for indirect MMT determinations based on total Mn concentrations.
A gas chromatographic protocol has been developed to determine MMT in ambient air. The limit of detection using this protocol is 0.05 ng/m3. MMT is trapped on Teflon-lined U-tubes packed with 3% OV-1 on Chromosorb W. During sampling the U-tubes are placed in a water-ice cooling bath and air is pumped through the U-tube at approximately 70 mL/min using a vacuum pump. Determination is made by gas chromatography with an electrothermal atomic absorption detector (Coe et al., 1980).
A similar procedure to Coe et al. (1980) for the determination of MMT in ambient air is described by Gaind et al. (1992). Airborne MMT is collected in XAD-2 containing tubes using an air-sampling pump. Determination is made by gas chromatography with an electron capture detector. The limit of detection using this protocol is 0.001 mg/m3 from a 10 L air sample.
A procedure for the determination of organic Mn in personal air samples has been described by Albemarle Corporation (1994). Determination is achieved by adsorption onto activated charcoal, followed by desorption by nitric acid, and then atomic absorption spectrophotometry. This protocol is applicable to organic Mn concentrations below 3 g Mn/mL nitric acid. The method does not distinguish between different organic Mn species. A glass fibre filter is attached to the front of the charcoal tube to remove inorganic (particulate) Mn.
A number of methods have been described for the determination of inorganic Mn in ambient air. These include x-ray fluorescence and inductivity coupled plasma atomic emission spectrophotometry (ATSDR 2000).
Share with your friends: |