4. Battery Chargers
|
B
|
2
|
1
|
(M) May be inoperative provided:
a) Both Engine Generators are operative,
b) APU Generator is operative,
c) Associated Battery Charger circuit breaker on the Power Distribution Box is pulled and collared, and
d) Standby Electrical System is operative.
|
Maintenance will pull and collar CB of associated Battery Charger (located on PDB). Maintenance can verify associated Battery Charger by utilizing Operational Test located in AMM Chapter 24-34-03.
Flight crew may accomplish this task if properly qualified and authorised.
|
None required.
|
An Inoperative Placard will be placed above Battery Charger Circuit Breakers and will be noted on ADLS.
|
5. Main Airplane
Batteries
|
B
|
2
|
1
|
(M) May be inoperative provided:
a) There are no other electrical power source failures,
b) Associated Battery cables are disconnected and secured,
c) Associated Battery Charger circuit breaker on the Power Distribution Box is pulled and collared, and
d) Associated battery circuit breaker is pulled and collared.
|
Maintenance will ensure:
-
Standby Electrical System is operative,
-
Pull and collar associated "BATT CHGR" and "BATT CONT" CB, and
-
Associated battery cables will be disconnected and secured. Refer to AMM chapter 24-34-00.
|
None required.
|
An Inoperative Placard will be placed on affected "BATT 1, BATT 2" Master Switch on the Electric Master Panel and will be noted on ADLS.
|
|
B
|
2
|
1
|
(M)(O) May be inoperative provided:
a) Airplane is operated in day VMC,
b) Standby Electrical System is operative,
c) Associated Battery cables are disconnected and secured,
d) Associated Battery Charger circuit breaker on the Power Distribution Box is pulled and collared, and
e) Associated battery circuit breaker is pulled and collared.
|
Maintenance will pull and collar associated "BATT CHGR" and "BATT CONT" CB. In addition, associated battery cables will be disconnected and secured. Refer to AMM chapter 24-34-00.
|
Flight crew will ensure airplane is operated in day VMC only.
|
An Inoperative Placard will be placed on affected "BATT 1, BATT 2" Master Switch on the Electric Master Panel and will be noted on ADLS.
|