U.S. DEPARTMENT OF TRANSPORTATION

MASTER MINIMUM EQUIPMENT LIST

FEDERAL AVIATION ADMINISTRATION


AIRCRAFT:

GULFSTREAM G-V, GV-SP,

GV-SP (G550), GV-SP (G500),

GIV-X, GIV-X (G450),

GIV-X (G350)


REVISION NO: 7

DATE: 02/04/2010



PAGE NO:

24-3


1. SYSTEM,

SEQUENCE NUMBERS & ITEM



REPAIR CATEGORY




2. NUMBER INSTALLED




3. NUMBER REQUIRED FOR DISPATCH




4. REMARKS OR EXCEPTIONS

24

ELECTRICAL POWER





































5.

Main Airplane Batteries

B

2

1

(M) May be inoperative provided:

  1. There are no other electrical power source failures,

  2. Associated Battery cables are disconnected and secured,

  3. Associated Battery Charger circuit breaker on the Power Distribution Box is pulled and collared, and

  4. Associated battery circuit breaker is pulled and collared.































B

2

1

(M)(O) May be inoperative provided:

  1. Airplane is operated in day VMC,

  2. Standby Electrical System is operative,

  3. Associated Battery cables are disconnected and secured,

  4. Associated Battery Charger circuit breaker on the Power Distribution Box is pulled and collared, and

  5. Associated battery circuit breaker is pulled and collared.




























U.S. DEPARTMENT OF TRANSPORTATION

MASTER MINIMUM EQUIPMENT LIST

FEDERAL AVIATION ADMINISTRATION


AIRCRAFT:

GULFSTREAM G-V, GV-SP,

GV-SP (G550), GV-SP (G500),

GIV-X, GIV-X (G450),

GIV-X (G350)


REVISION NO: 8

DATE: 11/07/2014



PAGE NO:

24-4


1. SYSTEM,

SEQUENCE NUMBERS & ITEM



REPAIR CATEGORY




2. NUMBER INSTALLED




3. NUMBER REQUIRED FOR DISPATCH




4. REMARKS OR EXCEPTIONS

24

ELECTRICAL POWER





































6.

Battery Ammeters (Overhead Panel)

C

2

0

May be inoperative provided:

  1. Associated voltmeter is operative, and

  2. Both battery charger fail messages are operative.































C

2

0

May be inoperative provided battery ammeter indications are available in EICAS.




























(EICAS Indication)

C

2

0

May be inoperative provided the battery ammeters in overhead panel are operative.

|
|
|






















7.

Battery Voltmeters

(Overhead Panel)



C

2

0

May be inoperative provided associated ammeter is operative.

|

|





























C

2

0

May be inoperative provided Battery Voltmeter indications are available on EICAS.

|

|

|



























(EICAS Indication)

C

2

0

May be inoperative provided Battery Ammeters indications are available on EICAS.

|
|
|




























C

2

0

May be inoperative provided Battery Voltmeters in overhead panel are operative.

|
|
|

























U.S. DEPARTMENT OF TRANSPORTATION

MASTER MINIMUM EQUIPMENT LIST

FEDERAL AVIATION ADMINISTRATION


AIRCRAFT:

GULFSTREAM G-V, GV-SP,

GV-SP (G550), GV-SP (G500),

GIV-X, GIV-X (G450),

GIV-X (G350)


REVISION NO: 8

DATE: 11/07/2014



PAGE NO:

24-5


1. SYSTEM,

SEQUENCE NUMBERS & ITEM



REPAIR CATEGORY




2. NUMBER INSTALLED




3. NUMBER REQUIRED FOR DISPATCH




4. REMARKS OR EXCEPTIONS

24

ELECTRICAL POWER





































8.

Electrical Power System EICAS Displays













|
|






















1)

L Gen Voltmeter

C

1

0

May be inoperative if the frequency and loadmeter are operative.

|
|






















2)

L Gen Frequency Meter

C

1

0

May be inoperative if the voltmeter and loadmeter are operative.

|
|






















3)

L Gen Loadmeter

C

1

0

May be inoperative if the voltmeter and frequency meter are operative.

|
|






















4)

R Gen Voltmeter

C

1

0

May be inoperative if the frequency and loadmeter are operative.

|
|






















5)

R Gen Frequency Meter

C

1

0

May be inoperative if the voltmeter and loadmeter are operative.

|
|






















6)

R Gen Loadmeter

C

1

0

May be inoperative if the voltmeter and frequency meter are operative.

|
|






















7)

APU Voltmeter

C

1

0

May be inoperative if the frequency meter and loadmeter are operative.

|
|






















8)

APU Frequency Meter

C

1

0

May be inoperative if the voltmeter and loadmeter are operative.

|
|






















9)

APU Loadmeter

C

1

0

May be inoperative if the voltmeter and frequency meter are operative.

|
|






















10)

Ext AC Pwr Voltmeter

D

1

0

May be inoperative provided:

a) the frequency meter and

loadmeter are operative, and

b) External AC power is not used.



|

|

|



|