Vessel Sanitation Program Construction Guidelines Draft final for clearance April 2011


Figure 8b: Unobstructed direct cleaning space, cleaning two sides



Download 2.04 Mb.
Page8/22
Date23.11.2017
Size2.04 Mb.
#34281
1   ...   4   5   6   7   8   9   10   11   ...   22

Figure 8b: Unobstructed direct cleaning space, cleaning two sides



Figure 8c: Unobstructed direct cleaning space, cleaning corner two sides
8.1.5 In case the unobstructed cleaning space includes a corner, the cleaning distance has to be treated separately in two sections. The farthest space behind the equipment has to be treated separately according to 8.1.1 – 8.1.4. The closer space beside the equipment has to be treated by calculating closer and farther cleaning distance together and using cleaning space according to 8.1.1-8.1.4. The closer space always has to be minimum 300 mm (12 inches).




Download 2.04 Mb.

Share with your friends:
1   ...   4   5   6   7   8   9   10   11   ...   22




The database is protected by copyright ©ininet.org 2024
send message

    Main page