# - ISO Guide 34, ILAC Guide 13
C - Currently accredited/certified and/or have been reviewed.
P ā assessments / reviews in progress by TCs
N - Not yet apply
Pathway
a) Third party accreditation.
b) Certification to ISO 9001 and attestation by technical peers.
c) Attestation by a team consisting of quality system experts and technical peers.
6. List of APMP key and supplementary comparisons
AUV: Acoustics, Ultrasonic and Vibration
Name of comparison
|
Field
|
Pilot Lab
|
Participating Laboratory
|
Period or Status
|
APMP.AUV.A-K1
|
Standard microphones type LS1P
|
NMIJ
|
9
|
Published in KCDB in May 2006
|
APMP.AUV.A-K3
|
Standard LS2P microphones
|
KRISS
|
10
|
In progress
|
EM: Electric and Magnetism
Name of comparison
|
Field
|
Pilot Lab
|
Participating Laboratory
|
Period or Status
|
P1-APMP.EM.BIPM-K11.1
|
DC voltage (1.018 V, 10 V)
|
NMIA
|
Bi-lateral with SCL
|
Published in KCDB
|
P3-APMP.EM-S5
|
AC/DC transfer (0.5 V to 1000 V)
|
NMIA
|
Bi-lateral with NIMT
|
Published in KCDB
|
P2-APMP.EM-S6
|
Resistance 0.1 ohm to 100 M ohm
|
NMIA
|
Bi-lateral with NIMT
|
Published in KCDB
|
P1-APMP.EM.RF-S4
|
Calibration factor and effective efficiency on coaxials
|
NMIA
|
Bi-lateral with SCL
|
Published in KCDB
|
P1-APMP.EM.BIPM-K11.2
|
DC voltage 10 V
|
KIM-LIPI
|
Bi-lateral with SPRING
|
Draft B in preparation
|
P2-APMP.EM-K4.1
|
Capacitance 10 pF
|
NMIA
|
14
|
Draft A in preparation
|
P1-APMP.EM-K6.a
|
AC/DC transfer at 3 V
|
NMIA
|
14
|
Draft B in preparation
|
P1-APMP.EM-K9
|
AC/DC transfer at 500 V, 1000 V
|
CMS/ITRI
|
12
|
Draft B in preparation
|
P2-APMP.EM-S7
|
Capacitance 100 pF
|
NMIA
|
14
|
Draft A in preparation
|
P1-APMP.EM.RF-S3
|
Reflection coefficient on coaxials (50 ohm coaxial mismatch)
|
NPLI
|
6
|
Draft A in preparation
|
P1-APMP.EM.RF-K3.F
|
Horn antenna gain at 26.5, 33 and 40 GHz
|
KRISS
|
Bi-lateral with NMIJ
|
In progress
|
P1-APMP.EM-S5
|
Standards for DCV, ACV, DCI, ACI, R meters
|
NMIA
|
|
Preparing protocol and schedule
|
P1-APMP.EM-S8
|
Multimeter comparison
|
NPLI
|
|
Preparing protocol and schedule
|
APMP.EM.RF-K8.CL
|
RF power; 10 MHz to 18 GHz
|
NMIJ
|
|
Preparing protocol and schedule
|
APMP.EM.RF-K19.CL
|
Attenuation at 60 MHz and 5 GHz on coaxial
|
NIM
|
|
Preparing protocol and schedule
|
P1-APMP.EM-S4
|
AC/DC transfer (3 V to 1000 V)
|
NMIA
|
Bi-lateral with NPLI
|
Withdrawn (abandoned at the request of NPLI)
|
APMP.EM.BIPM-K11.a
|
DC Voltage: 1.018 V, Zener
|
KRISS
|
|
Planned
|
APMP.EM.BIPM-K11.b
|
DC Voltage: 10 V, Zener
|
KRISS
|
|
Planned
|
APMP.EM-K1.1
|
DC resistance: 1 ohm, 10 k ohm
|
NMIA
|
|
Planned
|
APMP.EM-K2
|
DC high resistance (10 M ohm, 1 G ohm)
|
KRISS
|
|
Planned
|
APMP.EM-K3
|
Inductance; 10 mH at 1 kHz
|
NPLI
|
|
Planned
|
APMP.EM-K5.1
|
AC Power: 120 V, 5 A, 53 Hz; Power factor 1.0
|
NIM
|
|
Planned
|
APMP.EM-K8
|
DC voltage ratio: 100 V/ 10 V and
1000 V/ 10 V
|
?
|
|
Planned
|
APMP.EM-K10
|
DC resistance: 100 ohm
|
SPRING
|
|
Planned
|
APMP.EM.M-K1.a
|
Magnetic quantities: DC
|
KRISS
|
|
Planned
|
L: Length
Name of comparison
|
Field
|
Pilot Lab
|
Participating Laboratory
|
Period or Status
|
APMP.L-K1
|
Length: Short Gauge blocks
|
NMIJ
|
11
|
Published in May 2006
|
APMP.L-K2
|
Length: Long Gauge blocks
|
NMIA
|
12
|
Published in May 2006
|
APMP.L-K3
|
Length: Angle Standards
|
CSIR
|
12
|
Started in May 2005
|
APMP.L-K4
|
Length: Diameter Standards
|
CMS
|
13
|
Surveying & Planning
|
APMP.L-K5
|
Length.1-D CMM
|
KRISS
|
14
|
Started in December 2005
|
APMP.L-K6
|
Length:2-D CMM
|
NMIJ
|
14
|
Started in April 2006
|
APMP.LK-11
|
Laser Frequency: 633 nm He-Ne laser
|
NIM
|
8
|
Report in progress, Draft A
|
APMP.L-K1.1
|
Gauge Blocks by Interferometer
|
NMIJ
|
7
|
Report in progress, Draft A
|
Bi-lateral
|
Autocollimator
|
NIMT
|
NMIJ, NIMT
|
Completed in Feb., 2006
|
APMP.L-S2
(Bi-lateral)
|
Nano scale 2-D gratings
|
NMIJ
|
NMIJ, PTB
|
Final report (draft B) completed in July 2006
|
Inter-RMO
|
Step Height and Roughness Standards
|
NMIA
|
17 or more
|
Planning
|
Multi-lateral
|
EDM
|
KRISS
|
KRISS, NMIJ, CMS and Finland
|
Measurement completed in September 2006
|
M: Mass and related quantities
Name of comparison
|
Field
|
Pilot Lab
|
Participating Laboratory
|
Period or Status
|
APMP.M.M-K2
|
Mass: 100 mg, 2 g, 20 g, 500 g, 10 kg
|
NPLI
|
12
|
Measurement completed
|
APMP.M.M-K6
|
Mass: 100 mg, 2 g, 20 g, 500 g, 1 kg
|
VMI
|
13
|
In progress
|
APMP.M.F-K4
|
Force
|
NMIJ
|
8
|
In progress
|
APMP.M.P-K1.c.1
|
Pressure: 0.4 MPa to 4.0 MPa in gas media and gas mode
|
CMS/ITRI
|
3
|
Draft B finished
|
APMP-SIM.M.P-K1c
|
Pneumatic pressure: 0.4 MPa to 4.0 MPa
|
|
NIST and NPLI
|
Draft B is finished
|
APMP.M.P-K5
|
Differential pressure: 1 Pa to 5000 Pa
|
NMIJ
|
2 (MSL and NMIJ)
|
Final report
|
APMP.M.P-K6
|
Pressure: 20 kPa to 105 kPa
|
NPLI
|
10
|
Draft A completed
|
APMP.M.P-K6.1
|
Pressure: 20 kPa to 105 kPa in gas media and gauge modde
|
CMS/ITRI
|
3
|
Draft A completed and in circulation
|
APMP.M.P-K7
|
Hydraulic gauge pressure: 10 MPa to 100 MPa
|
NMIJ
|
16
|
Published in KCDB in 2005
|
APMP-SIM.M.P-K7
|
Hydraulic pressure: 40 MPa to 200 MPa
|
NPLI
|
NIST and NPLI
|
Published in KCDB in 2006
|
APMP-SIM.M.P-S2
|
Pressure (vacuum) at 0.05 Pa
|
NPLI
|
NIST and NPLI
|
Draft A finished
|
APMP.M.H-K1.b,c
|
Hardness: Vickers 1, 30
|
NMIJ
|
7
|
Draft A preparing
|
APMP.M.H-S1
|
Rockwell hardness: 20 HRC to 60 HRC
|
NIMT
|
4
|
Draft A finished
|
Bilateral Intercomparison
|
Mass (2 kg, 100 g, 100 mg)
|
UME (Turkey)
|
UME, KRISS
|
Under process
|
APMP.FF-K4
|
Volume
|
NMIA
|
10
|
In process
|
APMP.D-K1
|
Density
|
KRISS
|
10
|
Planned (2007.7-2008.6)
|
APMP.M.P-K9
|
Pressure (vacuum)
|
NMIJ
|
|
Protocol preparing
|
APMP.M.F-K2
|
Force
|
KRISS
|
Under process
|
|
|
Gas pressure: 20 kPa to 105 kPa
|
NIMT
|
NPLI, PTB
|
Preparing the draft protocol
|
|
Torque: 40 to 1000 Nm
|
NIMT
|
VMI, PTB
|
Preparing the draft protocol
|
|
Leak standard
|
PTB
|
PTB, KRISS, NIST, NPLI, NMIJ etc.
|
Maybe 2007
|
|
Differential Pressure (Low line pressure)
|
KRISS (with NMIJ)
|
Under preparing by KRISS
|
Planned in the 2nd half of 2007
|
|
Mass: Programmes on calibration of Balances
|
NPLI
|
|
To be organized
|
|
Mass: A magnetism of weights comparison
|
NIM
|
|
To be organized
|
|
Mass: Standard
|
NPSL Pakistan,
Nepal Bureau of Standards and Metrology
|
|
To be organized
|
PR: Photometry and Radiometry
Name of comparison
|
Field
|
Pilot Lab
|
Participating Laboratory
|
Period or Status
|
CCPR-K3.a.1 & K3.b.1
|
Photometry: Luminous intensity & responsivity
|
NMIA
|
NMIA and SPRING (bi-lateral)
|
Published in KCDB in 2005
|
CCPR-K1.a.1
|
Radiometry: Spectral irradiance (250 to 1600 nm)
|
NMIA
|
NMIA and SPRING (bi-lateral)
|
Published in KCDB in 2006
|
APMP.PR-S1
|
Radiometry: Irradiance responsivity of UVA detectors
|
SPRING
|
7
|
Approved and published
|
APMP.PR-S2
|
Radiometry: Fibre optic power responsivity (1310 nm and 1550 nm)
|
KRISS
|
8
|
Measurement in progress
|
APMP.PR-K4
|
Photometry: Luminous flux
|
NIM
|
8
|
Measurement in progress
|
APMP.PR-K3.a.1
|
Photometry: Luminous intensity
|
NIM
|
NIM and SIRIM (bi-lateral)
|
Measurement
|
|
Photometry: Luminous intensity
|
NMIJ
|
6 or 7
|
Protocol in preparation
|
|
Spectrophotometry: Spectral diffused reflectance
|
KRISS
|
5 to 7
|
Need to change pilot lab due to change of personnel
|
|
Radiometry: Spectral power responsivity (300 ā 1000 nm)
|
NMIJ
|
4 to 7
|
Protocol in preparation
|
|
Photometry: LED intensity
|
KRISS
|
|
To be arranged
|
QM: Quantity of Material
Name of comparison
|
Field
|
Pilot Lab
|
Participating Laboratory
|
Period or Status
|
APMP.QM-K3
|
Automobile Emission Gas
|
|
|
Published in KCDB
|
APMP.QM-K4
|
Ethanol in nitrogen
|
|
|
Published in KCDB
|
APMP.QM-P01
|
p,pā-DDE in fish oil
|
NARL, Australia
|
|
completed
|
APMP.QM-P02
|
Cd in rice
|
NARL, Australia
|
|
completed
|
APMP.QM-P03
|
N, Ca, Cu, Pb in milk powder
|
NRCCRM
|
|
completed
|
APMP.QM-P04
|
p,pā-DDE in fish oil, follow-up of APMP.QM-P01
|
NARL, Australia
|
|
completed
|
APMP.QM-P05
|
Cadium in oyster tissue
|
KRISS
|
|
Completed
|
APMP.QM-P07
(CCQM-P64)
|
Trace elements in soybean powder
|
NRCCRM
|
|
Completed
|
APMP.QM-P08
|
SiO2 thickness on silicon
|
NMIJ
|
|
Completed
|
APMP.QM-P09
|
pH of phthalate buffer solutions
|
NMIJ
|
|
Completed
|
APMP.QM-S1
|
Gravimetry: nitrogen in helium
|
KRISS
|
|
In progress
|
APMP.QM-S2
|
Impurity analysis in methane
|
NMIJ
|
|
In progress
|
APMP.QM-K4.1
|
Ethanol in nitrogen
|
CERI, Japan
|
3
|
In progress
|
APMP.QM-K1.d
|
SO2 in nitrogen
|
CERI, Japan
|
3
|
In progress
|
APMP.QM-K1.c
|
NO in nitrogen
|
KRISS
|
2
|
In progress
|
APMP.QM-P10
|
Study of Cadmium and Lead in Herb (Herba Demodii Styracifolii)
|
GLHK, Hong Kong SAR
|
|
Proposed
|
APMP.QM-P11
|
Study of Total As and Arsenobetaine in marine fish (Swordfish)
|
NMIJ
|
|
Proposed
|
|
Acrylamide in potato chips
|
KRISS
|
|
Proposed
|
|
Metals in plastic
|
NIM
|
|
Proposed
|
|
Cadium in rice
|
KRISS
|
|
Proposed
|
Share with your friends: |