Minimum Requirements
|
Yes
|
No
|
---
|
(Not all inclusive, for additional items and clarification refer to contract – Section D)
|
---
|
---
|
1
|
Two copies of complete Agreement/Contract (D.8)
|
|
|
2
|
Serial# or VIN# on agreement and resource order, matches Serial# or VIN# on this Trailer (Schedule of Items) (D.6.3.1) (D.6.4.1)
|
|
|
3
|
Completed Check-In Process: Which also includes, Finance, and Plans (D.6.5.1) (D.6.5.3)
|
|
|
4
|
Successfully completed the Mechanical, OF-296 Inspection (Vehicle/Heavy Equipment Safety Inspection) at this incident, has completed OF-296 form in vehicle (D.17) (D.17.1)
|
|
|
5
|
External Generator: AC generator kit that includes; 1 whisper quiet generator with a minimum output capacity of 10,000 watts (10kw) . Capable of operating for one operational period without running out of fuel . (D.2.1.3_8)
|
|
|
6
|
External Generator: Generator positioned away from trailer . Has sound dampening material around generator . (D.2.1.3_8)
|
|
|
7
|
Exterior Lighting: Sufficient to provide adequate light for night time operations around
the trailer and briefing area (D.2.1.1_12)
|
|
|
8
|
Trailer Stabilizer (D.2.1.1_6)
|
|
|
9
|
Wind Sock: 30-mph wind sock (1 each). Capable of rotating without touching any obstacles (D.2.1.1_14)
|
|
|
10
|
Steps (stairs): No steep steps. Allows for safe entry and exit from trailer (D.2.1.1_13)
|
|
|
11
|
Qualified Technician: Qualified to maintain and program equipment (D.1) (D.2.1.1_2)
|
|
|
12
|
Unit: Minimum of 26 feet in length (D.2.1.1_1)
|
|
|
13
|
Unit: Two rooms with forced air to each room, separated by a door. (D.2.1.1_1)
|
|
|
14
|
Radio Room Windows: 180 degree windows (minimum) for visibility (D.2.1.1_1)
|
|
|
15
|
Pull Down Shades: No reflective tinted shades or window film (D.2.1.1_1)
|
|
|
16
|
Window Screens: Screens on all windows that open (D.2.1.1_1)
|
|
|
17
|
Air Conditioning: Units are self-contained, climate controlled units with air conditioning to maintain 70 -75 F degrees temperature in the trailer. (D.2.1.1_3)
|
|
|
18
|
Heaters: Must be operational (D.2.1.1_4)
|
|
|
19
|
Hand tool kit (for general use) (D.2.1.1_7)
|
|
|
20
|
White Boards: 36”x 24” (3 each). 1 is installed in the radio room, and 2 are installed on each wall of the general work area room (D.2.1.1_8)
|
|
|
#
|
Minimum Requirements – continued
|
-----
|
-----
|
21
|
Fax, Copier, Scanner: Arrived with 2 reams of paper (D.2.1.1_9)
|
|
|
22
|
High Capacity Printer: Prints a minimum of 28 pages per minute (D.2.1.1_9)
|
|
|
23
|
Cork Boards: 36”x 24” (3 each). 1 is installed in the radio room, and 2 are installed on each wall of the general work area room (D.2.1.1_10)
|
|
|
24
|
Internal Lighting: Adequate light for night time operations. Minimum 1 AC lighting fixture over each work area, (florescent lighting is acceptable) (D.2.1.1_11) (D.2.1.2_3)
|
|
|
25
|
Work Stations: (7 each). Three desktop/countertop workstations in the radio room, and four more in work area (can be continuous counter tops) (D.2.1.2_1)
|
|
|
26
|
Work Stations: Each individual desk top work space is a minimum of 18 inches deep by 36 inches long (D.2.1.2_2)
|
|
|
27
|
Chairs: Rolling chairs (7 each), one per work station (D.2.1.2_1_2)
|
|
|
28
|
Fire Extinguishers: 10-BC (1 each). 20-BC (1 each) (D.2.1.1_15)
|
|
|
29
|
Electrical: 120 volt, 50 amp AC service entrance w/disconnect switch to master breaker
(D.2.1.3_1)
|
|
|
30
|
Electrical: AC receptacles at all work stations/areas (D.2.1.3_2)
|
|
|
31
|
Electrical: 20 foot, 50 amp, AC service extension cable: 1 each (D.2.1.3_3)
|
|
|
32
|
Electrical: AC three pin twist-lock to standard 3 pin adapters (min. 20 amp) (D.2.1.3_4)
|
|
|
33
|
Battery Backup: DC battery backup with minimum 100AH capacity (D.2.1.3_5)
|
|
|
34
|
Battery Backup: Equipped with a master disconnect or breaker switch . Physically isolated from work area . Sealed, non-ventilating type (gel-cel) . (D.2.1.3_5_abc)
|
|
|
35
|
Charging System: DC charging system to maintain battery backup (D.2.1.3_6)
|
|
|
36
|
Auxiliary Connection: Auxiliary 12 volt connection power points near radio equipment (2 each) (D.2.1.3_7)
|
|
|
37
|
Radio Equipment: All radio equipment ready for immediate use upon arrival at the helibase, pending frequency programming (D.1) (D.2.1.4_4)
|
|
|
38
|
Interface devices or personal computers required for radio equipment within the trailer is available (D.2.1.4_6)
|
|
|
39
|
Software and all necessary hardware for radio frequency programing is provided (computer programming capable equipment) (D.2.1.4_2_5)
|
|
|
40
|
VHF-FM P25 Digital Base Station: VHF-FM mobile radios (3 each) . Each radio has a desk mic or handheld mic with adjustable volume controls (D.2.1.4_1)
|
|
|
41
|
VHF-FM P25 Digital Base Station: Two-way mobile radio (1 each), P25 Digital VHF-FM compliant . Equipped with a matched broadband antenna . Provides selections for: Analog Wideband , Analog Narrowband , and P25 Digital Narrowband . Radio is Frequency synthesized , with a minimum of 32 selectable tones (D.2.1.4_1_a)
|
|
|
42
|
UHF-FM Base Station: UHF-FM mobile radios (2 each) . Capability for a minimum of 10 preset channels . User programmable without the need of a computer . Each radio has a desk mic or handheld mic with adjustable volume controls (D.2.1.4_2)
|
|
|
43
|
VHF-AM Base Station: VHF-AM fixed (mobile or base) radios (2 each) . User programmable without the need of a computer . Each radio has a desk mic or handheld mic with adjustable volume controls (D.2.1.4_3)
|
|
|
44
|
Handheld Radios: VHF-AM handheld radios (2 each) . Field (user) programmable Battery packs, i.e. clamshells (2 each) (D.2.1.4_7)
|
|
|
45
|
Handheld Radios: P25 Digital VHF-FM handheld radios (2 each) . Provides selections for: Analog Wideband , Analog Narrowband , and P25 Digital Narrowband . Radio is Frequency synthesized , with a minimum of 32 selectable tones . Field (user) programmable . Battery packs, i.e. clamshells (2 each) (D.2.1.4_8_abc)
|
|
|
#
|
Minimum Requirements – continued
|
-----
|
-----
|
46
|
Base Station Antennas: VHF-AM broadband antenna , VHF-FM broadband antenna , UHF broadband antenna . Antennas tuned to proper frequency bands and cover required MHz spectrum for each base station radio (D.2.1.4_9_abc)
|
|
|
47
|
Magnetic Mounted Antennas: With a minimum of eight foot RF (radio frequency) cable for both VMF-FM and UHF-FM frequency bands (2 each) (D.2.1.4_9_d)
|
|
|
48
|
RF Cables: RF cable terminations are accessible from both inside and outside the trailer
(D.2.1.4_10)
|
|
|
49
|
RF Cables: All cables are RG-8 or better (D.2.1.4_10)
|
|
|
50
|
RF Cables: VHF cables are terminated with UHF connectors (D.2.1.4_10)
|
|
|
51
|
RF Cables: UHF cables are terminated with “N” connectors (D.2.1.4_10)
|
|
|
52
|
RF Cables: There is a VHF cable located at each work position (station) to an outside jack box . Also there is an selection of inter-series adapters available . (D.2.1.4_10)
|
|
|
53
|
Public Address System: 30 watt (minimum). Operated from the dispatch area, providing audio 360 degrees around external trailer area (D.2.1.4_11)
|
|
|
54
|
Timers or other time tracking devices: (10 each) (D.2.1.4_12)
|
|
|
55
|
Digital Weather Station: At a minimum, is able to measure wind speed, wind direction, and temperature (D.2.1.4_13)
|
|
|
56
|
Telephone: One (1) telephone service/customer entrance panel that accommodates a minimum of three (3) telephone lines within the trailer. (D.2.1.5_1)
|
|
|
57
|
Telephone Jacks: Pre-wired RJ-11phone jacks (4 each), wired with RJ-66 phone block
(D.2.1.5_2)
|
|
|
58
|
Telephone Jacks: Prewired RJ-45 wall jacks (4 each) (D.2.1.5_3)
|
|
|
59
|
Telephone Handsets: (3 each). Near work area (D.2.1.5_4)
|
|
|
60
|
All necessary fuel and power, (self-sufficient) (D.2.1.1_5)
|
|
|
---
|
OPTIONAL
|
-----
|
-----
|
61
|
Satellite or High Speed Internet:
Note: If internet is provided by this vendor, coordinate with the Communications Unit Leader. Refer to schedule of items of this agreement and (D.2.1.5_5)
|
|
|