Chapter 3 – Field Practice Assignment
What personal Protective equipment should a field engineer use?
Hardhats, Eye Protection, Hand Protection, Fall Protection, Safety Vests, Ear Protection, Foot Protection.
List 5 mistakes that commonly occur in surveying measurement.
Forgetting a foot was cut.
Reading a rod one foot off.
Setting an instrument one degree off.
Lack of knowledge about equipment.
Carelessness
Explain how you would describe to someone the difference between mistakes and errors
Mistakes are considered large and occur because of carelessness.
Errors Typically are very small mainly because of human limitations and always exist.
8. Develop a poster on equipment care that you would use to keep instruments clean.
XTransportation of Surveying Equipment
|
General Instrument Care and Use
|
Tripods
|
|
Transport Instrument in Case
|
Attach Instrument Snugly to Tripod
|
Position Legs Properly
|
|
Keep Empty Case Closed
|
Grasp Instrument Firmly
|
Keep it Horizontal
|
|
Carry the Instrument
|
Do not Touch lens
|
Keep it tight
|
|
|
|
|
Keep equipment Dry
|
Ensure a solid setup
|
|
|
|
|
Never Leave instrument Unattended
|
Secure adjustable legs
|
|
|
|
|
Establish a wide foundation
|
Maintained Proper Tension
|
|
|
|
|
Never Force any motion
|
When lubricating tripod apply silicone
|
|
|
|
Never force the instrument
|
Check all screws and bolts
|
|
|
|
|
Keep it clean
|
Do not abuse equipment
|
|
|
|
|
Return the instrument to its case
|
Protect the head of tripod
|
|
|
|
|
Climatize the instrument
|
Transport Carefully
|
|
|
|
|
|
|
|
|
|
|
12. Develop an instrument care and maintenance chart to be used to regularly clean equipment.
Maintenance Item
|
Daily
|
Weekly
|
Monthly
|
Yearly or seasonal
|
Start of New Job
|
When New
|
Wipe Clean
|
Chain, Tripod, Level Rod, Prism Pole
|
All
|
|
|
All
|
|
Deep Clean
|
|
Level Rod, Prism Pole
|
Tripod Level Rod, Laser
|
All
|
All
|
|
Lubricate (Dry Teflon Spray)
|
|
|
Tripod Level Rod, Prism Pole
|
|
|
|
Check Correct Calibration
|
Prism Pole Bubble
|
Auto Level, Tribrach
|
Laser
|
Total Station, Transit/ Theodol ite
|
All
|
Chain Level Rod and All instruments.
|
Check Instrument Constants
|
Total Station, Digital Level, GPS
|
|
|
|
|
|
Lens Cleaning
|
As Needed- Camera Cleaning Kit Only!
|
|
|
|
|
|
13. Describe why the left-thumb rule works
All leveling manufactures use the same type of threads on there leveling screws allowing the left thumb rule to work both thumbs out the bubble will follow the left thumb both thumbs in the bubble will follow the right thumb.
15. Outline the process used to set up an instrument with an optical plummet.
1. Rough- set up the tripod.
2. Attach the instrument to the tripod
3. Center the optical plummet
4. Adjust the tripod legs
5. Confirm the position
6. Center the bubble
7. Check the relation
8. Loosen the instrument attachment
9. Tighten the attachment clamp
10. Re-level and repeat