SECTION 08570


COMPOSITE WINDOWS AND DOORS
(Andersen Windows Inc 100 Series)

Display hidden notes to specifier. (Don't know how? Click Here)



Copyright 2012 - 2014 ARCAT, Inc. - All rights reserved

** NOTE TO SPECIFIER ** Andersen Windows, Inc.; windows and doors.
.
This section is based on the products of Andersen Windows, Inc., which is located at:
100 Fourth Ave. N. P. O. Box 12
Bayport, MN 55003-1096
Toll Free Tel: 800-299-9029
Tel: 651-264-5150
Fax: 752-752-9230
Email: request info (apanning@andersencorp.com)
Web: www.andersenwindows.com
Click Here for additional information.

For over 100 years, Andersen has been making windows and doors that are different and better than any others. Today, we offer five distinct product lines to provide the exact combination of economy, performance, aesthetics and architectural authenticity for any type of home and every homeowner’s taste. Find the one that’s right for you.



See our SpecWizard: Click Here




  1. GENERAL

    1. SECTION INCLUDES

** NOTE TO SPECIFIER ** Delete items below not required for project.

      1. Composite windows of the following types: (Andersen Windows Inc 100 Series)

        1. Single-hung windows.

        2. Casement windows.

        3. Awning windows.

        4. Gliding windows.

        5. Picture windows.

        6. Fixed windows.

      2. Composite gliding patio doors. (Andersen Windows Inc 100 Series)

    1. RELATED SECTIONS

** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required.

      1. Section 04810 - Unit Masonry Assemblies: Openings in masonry.

      2. Section 05400 - Cold Formed Metal Framing: Framed Openings.

      3. Section 06100 - Rough Carpentry: Framed openings.

      4. Section 06200 - Finish Carpentry: Interior wood casing.

      5. Section 07210 - Building Insulation: Batt insulation at window perimeter.

      6. Section 07460 - Siding and trim: Exterior siding and trim.

      7. Section 07620 - Flashing and Sheet Metal: Flashing associated with windows and doors.

      8. Section 07900 - Joint Sealers: Perimeter joint sealant and backer rod.

    1. REFERENCES

** NOTE TO SPECIFIER ** Delete references from the list below that are not actually required by the text of the edited section.

      1. AAMA 511 - Voluntary Guideline for Forensic Water Penetration Testing of Fenestration Products.

      2. AAMA 502 - Voluntary Specification for Field Testing of Windows and Sliding Glass Doors.

      3. AAMA/WDMA/CSA 101/I.S.2/A440 NAFS - North American Fenestration Standard/Specification for windows, doors, and skylights.

      4. ASTM International (ASTM):

        1. ASTM C 1036 - Standard Specification for Flat Glass.

        2. ASTM C 1048 - Standard Specification for Heat-Treated Flat Glass--Kind HS, Kind FT Coated and Uncoated Glass.

        3. ASTM E 90 - Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements.

        4. ASTM) E 330 - Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference.

        5. ASTM E 2190 - Standard Specification for Insulating Glass Unit Performance and Evaluation.

      5. American Society of Civil Engineers (ASCE) 7 - Minimum Design Loads for Buildings and Other Structures.

      6. International Standards Organization (ISO) 14021 - Environmental Labels and Declarations -- Self-Declared Environmental Claims (Type II environmental labeling).

      7. National Fenestration Rating Council (NFRC) 100 - Procedure for Determining Fenestration Product U-factors.

      8. National Fenestration Rating Council (NFRC) 200 - Procedure for Determining Fenestration Product Solar Heat Gain Coefficient and Visible Transmittance at Normal Incidence.

      9. WDMA I.S.4 - Water-Repellent Preservative Treatment for Millwork.

    1. SYSTEM DESCRIPTION

** NOTE TO SPECIFIER ** Refer to website for most current product performance data. Retain, edit, or delete language below to suit project requirements. Refer to www.andersenwindows.com for performance information.

      1. Performance Requirements: Provide products/systems that have been manufactured, fabricated, and installed to the following performance criteria:

        1. Comply with AAMA/WDMA/CSA 101/I.S.2/A440.

** NOTE TO SPECIFIER ** Specify performance grade.

        1. Performance Grade:

** NOTE TO SPECIFIER ** Specify U-Factor.

        1. U-Factor (NFRC 100):

** NOTE TO SPECIFIER ** Specify SHGC.

        1. Solar Heat Gain Coefficient (SHGC) (NFRC 200):

** NOTE TO SPECIFIER ** Specify OITC.

        1. Outdoor-Indoor Transmission Class (OITC) (ASTM E90 :

** NOTE TO SPECIFIER ** Specify STC.

        1. Sound Transmission Class (STC) (ASTM E90):

** NOTE TO SPECIFIER ** Manufacturer recommends referring to website design pressure estimator for additional wind load information. Retain, edit, or delete language below to suit project requirements.

      1. Structural Requirements: Provide products/systems capable of withstanding wind loads based on testing units representative of those indicated for Project that pass AAMA/WDMA/CSA 101/I.S.2/A440, Uniform Structural Load Test:

        1. Design Wind Loads: Determine design wind loads applicable to Product from basic wind speed indicted in miles per hour (meters per second) at 33 feet (10 meters) above grade, according to ASCE-7, Section 6, based upon mean roof heights indicted on Drawings.

** NOTE TO SPECIFIER ** Specify wind speed.

          1. Basic Wind Speed:

** NOTE TO SPECIFIER ** Specify importance factor.

          1. Importance Factor:

** NOTE TO SPECIFIER ** Specify exposure category.

          1. Exposure Category:

** NOTE TO SPECIFIER ** Specify design pressure requirement.

          1. Wind Load Requirement:

    1. SUBMITTALS

      1. Submit under provisions of Section 01300.

      2. Product Data: Manufacturer's data sheets on each product to be used, including:

        1. Preparation instructions and recommendations.

        2. Storage and handling requirements and recommendations.

        3. Installation methods.

      3. Shop Drawings: Provide drawings indicating direction of operable parts, typical jamb, head and sill conditions, and special mullion reinforcement details.

      4. Quality Assurance/Control Submittals:

        1. Performance Data: Manufacturer's published performance data for specified products.

** NOTE TO SPECIFIER ** Delete if not required.

      1. Sustainable Building Submittals:

** NOTE TO SPECIFIER ** Retain subparagraph below and energy performance certification paragraph in quality assurance article if windows are required to be certified. Delete if not required.

        1. Energy Performance:

          1. Provide NFRC 100 and NFRC 200 Certified performance values meeting or exceeding values specified in Performance Criteria Article.

** NOTE TO SPECIFIER ** Retain subparagraph below and recycled content certification in quality assurance article. Delete if not required.

        1. Recycled Content:

          1. Provide values in percent by weight of recycled content per ISO 14021 Standard for each product specified.

          2. Provide statement indicating total content value for each product containing recycled content and fraction by weight that is considered recycled content.

** NOTE TO SPECIFIER ** Retain paragraph below if windows are required to be certified for indoor air quality Delete if not required.

        1. Indoor Environmental Quality:

          1. Provide third party certification that window materials, including factory applied finishes, meet indoor air quality standards for low emitting materials under California CA Section 01350 Specifications.

** NOTE TO SPECIFIER ** Delete selection samples if colors have already been selected. Delete if not required.

      1. Selection Samples: For each finish product specified, two complete sets of color chips representing manufacturer's full range of available colors and patterns.

        1. Hardware: Sample indicating typical finish on hardware.

        2. Exterior: Samples of exterior colors.

      2. Verification Samples: For each finish product specified, two samples, minimum size 6 inches (150 mm) square, representing actual product, color, and patterns.

        1. Hardware: Sample indicating typical finish on hardware.

        2. Exterior: Samples of exterior colors.

      3. Manufacturer's Warranty: Submit, for Owner's acceptance, manufacturer's standard limited warranty document.

      4. Owner's Manual: Bound manual clearly identified with project name, location, and completion date. Identify type and size of units installed. Provide recommendations for periodic inspections, care, and maintenance. Identify common causes of damage with instructions for temporary repair.

    1. QUALITY ASSURANCE

      1. Manufacturer Qualifications: A manufacturer capable of fabricating windows that meet or exceed Performance Criteria indicated and of documenting this performance by inclusion in lists and by labels, test reports, and calculations.

      2. Installer Qualifications: Utilize an installer having demonstrated experience on projects of similar size and complexity.

** NOTE TO SPECIFIER ** Paragraph below should list obligations for compliance with specific code requirements particular to this section. General statements to comply with a particular code are typically addressed in Conditions of the Contract and Division 01 Section - Regulatory Requirements. Repetitive statements should be avoided.

      1. Regulatory Requirements and Approvals:

      2. Certifications:

        1. National Fenestration Rating Council (NFRC). Products shall be certified and labeled for U-Factor, Solar Heat Gain Coefficient (SHGC), and Visible Transmittance per NFRC 100 and 200 Procedures. Unique glass types that are special ordered may not apply, check with Manufacturer.

        2. Window and Door Manufacturers Association (WDMA). Products shall be certified and labeled per WDMA Hallmark Certification Program to the AAMA/WDMA/CSA 101/I.S.2/A440 industry standard.

** NOTE TO SPECIFIER ** Delete certification label not required.

        1. Insulating Glass Units: Provide insulating glass units permanently marked with certification label of Insulating Glass Certification Council (IGCC) indicating compliance with ASTM E2190.

        2. Insulating Glass Units: Provide insulating glass units permanently marked with certification label of Insulating Glass Manufacturers Association of Canada (IGMAC) indicating compliance with CAN/CGSB or ASTM E2190.

** NOTE TO SPECIFIER ** Retain paragraph below if pre-installation meeting is required. Specify requirements for pre-installation meeting.

      1. Pre-Installation Meetings: Conduct meeting at Project site to comply with requirements in Division 01 Section - Project Management and Coordination.

** NOTE TO SPECIFIER ** Include a mock-up if the project size and/or quality warrant taking such a precaution. The following is one example of how a mock-up on a large project might be specified. When deciding on the extent of the mock-up, consider all the major different types of work on the project.

      1. Mock-Up: Provide a mock-up for evaluation of surface preparation techniques and application workmanship.

        1. Finish areas designated by Architect.

        2. Do not proceed with remaining work until workmanship, color, and sheen are approved by Architect.

        3. Refinish mock-up area as required to produce acceptable work.

    1. DELIVERY, STORAGE, AND HANDLING

      1. Comply with manufacturer's ordering instructions and lead time requirements to avoid construction delays.

      2. Delivery: Deliver materials in manufacturer's original unopened, undamaged containers with identification labels intact.

      3. Storage and Protection: Store materials protected from exposure to harmful environmental conditions and at temperature and humidity conditions recommended by the manufacturer.

      4. Store materials and accessories off ground, under cover, and protected from weather and construction activities.

      5. Store and dispose of solvent-based materials, and materials used with solvent-based materials, in accordance with requirements of local authorities having jurisdiction.

    2. PROJECT CONDITIONS

      1. Field Measurements: Verify actual dimensions of openings by field measurements before fabrication. Record measurements on shop drawings. Coordinate field measurements and fabrication schedule with construction progress to avoid construction delays.

      2. Install units in accordance with manufacturer's safety and weather requirements.

        1. Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's absolute limits.

    3. WARRANTY

** NOTE TO SPECIFIER ** Andersen window & doors are covered by our exclusive Owner-to-Owner limited warranty. Most other window warranties end when a home is sold, but our coverage is completely transferable from each owner to the next. And, because it is not prorated, the coverage offers full benefits, year after year, owner after owner, so it can add real value when you decide to sell your home. Plus, we have one of the largest service networks in the industry, so help is always there if you need it.

      1. Project Warranty: Refer to Conditions of the Contract for project Warranty provisions.

** NOTE TO SPECIFIER ** Coordinate article below with manufacturer's warranty requirements. Visit the Andersen website for a complete description of the standard limited warranty including exclusions and limitations.

      1. Manufacturer's Warranty: Manufacturer's standard limited warranty.

        1. Non-prorated. Transferable from owner to the next.

        2. Term: 10 years on glass.

        3. Term: 10 years on non-glass parts.

      2. Andersen 100 Series window units are warranted to be free from defects in manufacturing, materials and workmanship for ten years from the date of purchase.

      3. The glass is warranted not to develop, under normal conditions, any material obstruction of vision resulting from manufacturing defects or as a result of premature failure of the glass or organic seal for ten years from the date of purchase.

  1. PRODUCTS

    1. MANUFACTURERS

      1. Acceptable Manufacturer: Andersen Windows, Inc., which is located at: 100 Fourth Ave. N. P. O. Box 12 ; Bayport, MN 55003-1096; Toll Free Tel: 800-299-9029; Tel: 651-264-5150; Fax: 752-752-9230; Email: request info (apanning@andersencorp.com); Web: www.andersenwindows.com

** NOTE TO SPECIFIER ** Delete one of the following two paragraphs; coordinate with requirements of Division 1 section on product options and substitutions.

      1. Substitutions: Not permitted.

      2. Requests for substitutions will be considered in accordance with provisions of Section 01600.

** NOTE TO SPECIFIER ** When designing window sizes, consult with Andersen window's 100-series window product guide document available at www.andersenwindows.com for full description of clear opening dimensions and positions.

    1. WINDOWS

** NOTE TO SPECIFIER ** Delete window products not required for project. Delete if not required.

      1. Single-Hung Windows:

        1. Product: Andersen 100 Series Single-Hung Windows.

        2. Product: Andersen 100 Series Archtop Single-Hung Windows.

** NOTE TO SPECIFIER ** Andersen casement windows have a hinge at the side and crank open outward. Delete if not required.

      1. Casement Windows:

        1. Product: Andersen 100 Series Casement Windows.

** NOTE TO SPECIFIER ** Andersen awning windows have a hinge at the top and open outward. Delete if not required.

      1. Awning Windows:

        1. Product: Andersen 100 Series Awning Windows.

      2. Gliding Windows:

        1. Product: Andersen 100 Series Gliding Windows.

** NOTE TO SPECIFIER ** Andersen picture windows are stationary windows designed to match single-hung, gliding or casement windows. Picture windows have no moving hardware and offer a wider, brighter view of the outdoors. Delete if not required.

      1. Picture Windows:

        1. Product: Andersen 100 Series Picture Windows.

** NOTE TO SPECIFIER ** Delete if not required.

      1. Fixed Windows:

        1. Product: Andersen 100 Series Fixed Windows.

      2. Materials

        1. Frame and Sash: Fabricated from extruded Fibrex composite profiles in the following co - extruded capstock finish color:

          1. Interior Finish: White.

** NOTE TO SPECIFIER ** Delete exterior finish color not required.

          1. Exterior Finish: White.

          2. Exterior Finish: Sandtone.

          3. Exterior Finish: Terratone.

          4. Exterior Finish: Cocoa Bean.

          5. Exterior Finish: Dark Bronze.

          6. 3-1/4 inches (82.5 mm) frame depth.

** NOTE TO SPECIFIER ** Delete nailing flange not required.

          1. Nailing Flange: 1-3/8 inches (35 mm) Flange setback.

          2. Nailing Flange: 1 inch (25 mm) Flange setback with stucco key.

          3. Nailing Flange: No nailing flange. Replacement configuration.

** NOTE TO SPECIFIER ** Delete weatherstripping not required.

        1. Weatherstripping: Single-Hung and Gliding.

          1. Head Weatherstripping: Fin/pile.

          2. Jamb Weatherstripping: Fin/pile.

          3. Check Rail Interlock Weatherstripping: Fin/pile.

          4. Vertical Weatherstripping: Fin/pile.

        2. Weatherstripping: Venting/Stationary Sash.

          1. Flexible tubular vinyl.

          2. Flexible leaf vinyl.

      1. Glazing

** NOTE TO SPECIFIER ** Delete certification not required.

        1. Certification: Insulating glass units certified through the Insulating Glass Certification Council as conforming to the requirements of IGCC. Provide dual sealed units consisting of polyisobutylene primary seal and silicone secondary seal. Provide metal spacers with bent or soldered corners.

        2. Certification: Insulating glass units certified through the Insulating Glass Manufacturers Alliance of Canada (IGMAC) conforming to the requirements of Canadian General Standards Board CAN/CGSB 12.8. Provide dual sealed units consisting of polyisobutylene primary seal and silicone secondary seal. Provide metal spacers with bent or soldered corners.

        3. Where safety glass is indicated or required by applicable code, provide Kind FT heat-treated float glass.

** NOTE TO SPECIFIER ** Select between the following standard glazing options. Consult Andersen Corporation for additional glazing options. In addition to complying with safety glazing requirements, tempered glass may be required because of window size and wind load. Consult Andersen Corporation for assistance in selecting appropriate glazing type. Delete glass units not required.

        1. Dual-Pane Insulating Glass Units:

** NOTE TO SPECIFIER ** Delete glass type not required.

          1. Glass: Insulating glass units consisting of 2 lites of clear annealed glass conforming to ASTM C1036, Type 1, Class 1, q3.

          2. Glass: Insulating glass units consisting of 2 lites of clear tempered glass conforming to ASTM C1048, Type 1, Class 1, q3, Kind FT where indicated on Drawings and as required by window manufacturer.

          3. Glass: Insulating glass units consisting of an outboard lite of clear tempered glass conforming to ASTM C1048, Type 1, Class 1, q3, Kind FT and the following patterned glass:

** NOTE TO SPECIFIER ** Delete pattern not required.

            1. Inboard Pattern Glass Lite: Cascade.

            2. Inboard Pattern Glass Lite: Fern.

            3. Inboard Pattern Glass Lite: Obscure.

            4. Inboard Pattern Glass Lite: Reed.

          1. Glass Thickness:

          2. Air Space: 9/16 inch (15 mm).

          3. Filling: Fill space between glass lites with argon gas blend.

        1. Low-E Glass Argon Gas Blend Filled Insulating Glass Units:

** NOTE TO SPECIFIER ** Delete glass type not required.

          1. Glass - Operating Units: Insulating glass units consisting of an outboard lite of clear annealed glass conforming to ASTM C1036, Type 1, Class 1, q3 and an inboard lite of clear glass conforming to ASTM C1048, Type 1, Class 1, q3, Kind HS.

          2. Glass: Tempered insulating glass units consisting of an outboard and inboard lite of clear tempered glass conforming to ASTM C1048, Type 1, Class 1, q3, Kind FT.

** NOTE TO SPECIFIER ** Delete pattern not required.

            1. Inboard Pattern Glass Lite: Cascade.

            2. Inboard Pattern Glass Lite: Fern.

            3. Inboard Pattern Glass Lite: Obscure.

            4. Inboard Pattern Glass Lite: Reed.

          1. Glass Thickness:

          2. Air Space: 9/16 inch (15 mm).

          3. Filling: Fill space between glass lites with argon gas blend.

        1. SmartSun™Low-E Glass, Low SHGC, Argon Gas Blend Filled Insulating Glass Units:

** NOTE TO SPECIFIER ** Delete glass type not required.

          1. Glass - Operating Units: Insulating glass units consisting of an outboard lite of clear annealed glass conforming to ASTM C1036, Type 1, Class 1, q3.

          2. Glass: Tempered insulating glass units consisting of an outboard and inboard lite of clear tempered glass conforming to ASTM C1048, Type 1, Class 1, q3, Kind FT.

** NOTE TO SPECIFIER ** Delete pattern not required.

            1. Inboard Pattern Glass Lite: Cascade.

            2. Inboard Pattern Glass Lite: Fern.

            3. Inboard Pattern Glass Lite: Obscure.

            4. Inboard Pattern Glass Lite: Reed.

          1. SmartSun™ Low-E Glass Coating: Magnetron sputtering vapor deposition (MSVD) Low-E coating applied to the No. 2 surface.

          2. Glass Thickness:

          3. Air Space: 9/16 inch (15 mm).

          4. Filling: Fill space between glass lites with argon gas blend.

      1. Hardware

** NOTE TO SPECIFIER ** Delete hardware not required.

        1. Hardware: Single-Hung and Gliding Window.

          1. Sash Locks and Keepers: Self latching sash locks with the following integral color:

            1. Color: White.

** NOTE TO SPECIFIER ** Single-hung windows. Delete if not required.

          1. Single-Hung Balances: Fit bottom sash with concealed frame mounted balances consisting of spring loaded block and tackle. Design balances to ensure easy operation of single-hung units.

** NOTE TO SPECIFIER ** Gliding window. Delete if not required.

          1. Rollers: Fit operating sash with 2 dual brass adjustable rollers.

          2. Guides: Provide extruded PVC glide track for operating sash.

            1. Color: White.

        1. Hardware: Venting Casement/Awning.

          1. Hardened steel operator arm stamped with a gear ring. Set arm gear between nylon bushing and nylon spacer. Encased drive shaft and worm gear assemblies in zinc die cast base and removable polycarbonate cover.

          2. Hinges: Stainless steel and heavy gauge steel arms. Stainless steel reinforcing insert in low friction shoe for casement units.

          3. Folding handle with powder coated painted finish and polycarbonate operator cover with integral color in the following finish.

            1. Color: White.

          4. Lock Handle and Bezel: Polycarbonate following integral color:

            1. Color: White.

          5. Sash Locks: Single actuation lock concealed by trim stops. Galvanized steel and engineered polymer components.

      1. Joining Systems:

** NOTE TO SPECIFIER **Andersen strongly recommends consultation with an experienced structural engineer, architect or contractor, and a local Andersen representative when specifying Andersen joining systems. Local design wind load requirements must be determined by specifier to select proper reinforcing methods for project-specific applications.

        1. Wood Non-Reinforced Joining: Machined LVL wood members treated with water repellent preservative after machining per WDMA I.S.4.

          1. Gusset Plates: Galvanized steel plates that attach to wood frame.

          2. Exterior Trim Strips: As recommended by window manufacturer for each joining method used.

          3. Color: Match window unit exterior color.

        2. Fasteners: Corrosion-resistant screws as provided by window manufacturer for fastening reinforcement members to wood frame and fastening end brackets to reinforcement members. Other fasteners provided by window installer.

        3. Sealant: As recommended by door manufacturer.

        4. Provide vinyl trim strips as recommended by window manufacturer for each joining method used.

          1. Color: Match window unit exterior color.

        5. Provide Head Flashing: Full-length aluminum drip cap.

          1. Color: Match window unit exterior color.

        6. Jamb clips: Galvanized steel.

      1. Accessories

** NOTE TO SPECIFIER ** Coordinate grille material of adjacent unit for joined units of different types. Standard grille width is 3/4 inch (19 mm). Hardwood maple grilles are provided for picture windows and are available for other window types on special order. Consult an Andersen representative for additional grille options.

        1. Grilles:

** NOTE TO SPECIFIER ** Refer to Andersen Divided Light Pattern Guide for available divided light patterns and details. Exterior and interior colors can be different. Retain project required grille pattern subparagraph below and delete subparagraphs not required.

          1. Finelight™ Grilles: Provide contour profile aluminum muntin bars permanently mounted within insulating glass unit where indicated on Drawings.

            1. Grille Intersections: ABS concealed plastic connectors with nylon end keepers.

            2. Width: 3/4 inch (19 mm).

            3. Interior Surface: White color painted finish.

** NOTE TO SPECIFIER ** Delete exterior surface finish not required.

            1. Exterior Surface: White color painted finish.

            2. Exterior Surface: Sandtone color painted finish.

            3. Exterior Surface: Terratone color painted finish.

            4. Exterior Surface: Cocoa Bean color painted finish.

            5. Exterior Surface: Dark Bronze color painted finish.

** NOTE TO SPECIFIER ** Delete pattern not required.

            1. Pattern: As Indicated On Drawings.

            2. Pattern: Colonial.

            3. Pattern: Modified Colonial.

            4. Pattern: Prairie A (9 Light).

            5. Pattern: Renaissance.

            6. Pattern: Short Fractional.

            7. Pattern: Specified Equal Light.

            8. Pattern: Sunburst.

            9. Pattern: Tall Fractional.

            10. Pattern: Victorian.

** NOTE TO SPECIFIER ** Delete insect screen not required.

        1. Insect Screens: Provide venting sash with an insect screen, including attachment hardware.

          1. Frames: 0.024 inch (0.61 mm) rolled aluminum frame with chromate conversion coating. Provide matching corner locks and latch retainers.

          2. Insect Screen Cloth: Fiberglass mesh, gunmetal finish.

** NOTE TO SPECIFIER ** Delete frame finish color not required.

          1. Frame Finish: Painted finish Color - White.

          2. Frame Finish: Painted finish Color - Sandtone.

          3. Frame Finish: Painted finish Color - Terratone.

          4. Frame Finish: Painted finish Color - Cocoa Bean.

          5. Frame Finish: Painted finish Color - Dark Bronze.

        1. TruScene Insect Screen: Provide venting sash with an insect screen, including attachment hardware.

          1. Frames: 0.024 (0.61 mm) inch rolled aluminum Frame Finish:

          2. Insect Screen Cloth: 25 by 25 mesh per inch micro fine stainless steel wire with a polyester non-reflective coating.

** NOTE TO SPECIFIER ** Delete frame finish color not required.

          1. Frame Finish: Painted finish Color - White.

          2. Frame Finish: Painted finish Color - Sandtone.

          3. Frame Finish: Painted finish Color - Terratone.

          4. Frame Finish: Painted finish Color - Cocoa Bean.

          5. Frame Finish: Painted finish Color - Dark Bronze.

** NOTE TO SPECIFIER ** Delete if not required.

        1. Continuous Drip Cap: Heavy 24-gauge aluminum construction. Stock lengths in finish to match frame.

      1. Fabrication:

        1. Composite Material: Fibrex as manufactured by Aspen Research Corporation. a wholly-owned subsidiary of Andersen Windows, Inc.

          1. Composite material is a patented material made of reclaimed wood fiber from wood window manufacturing operations and a thermoplastic polymer. The resultant pellets are extruded into cellular frame and sash profiles.

          2. The thermoplastic polymer resists rot, decay, and fungal growth. Warranted not to flake, blister, peel, pit or corrode. No wood preservative treatment or painting is required.

          3. Sash Members: Composite material sash members with co-extruded interior and exterior colored cap stock.

          4. Frame Units: Composite material frame member co-extruded interior and exterior colored cap stock and with co-extruded flanges for installation.

        2. Glazing: Factory glazed with glazing sealant and snap-in rigid vinyl glazing bead.

        3. Weatherstripping: Factory-applied to unit frame. Field-applied interlocking weatherstripping at panel meeting stiles.

** NOTE TO SPECIFIER ** Delete if not required.

    1. DOORS

      1. Gliding Patio Doors:

        1. Product: Andersen® 100 Series Gliding Patio Doors.

      2. Materials:

        1. Frame and Door: Fabricated from Fibrex® composite material, in the following color:

** NOTE TO SPECIFIER ** Retain project required color below. Delete color not required.

          1. Interior Frames: White.

          2. Exterior Frames: White.

          3. Exterior Frames: Sandtone.

          4. Exterior Frames: Terratone®.

          5. Exterior Frames: Cocoa Bean.

          6. Exterior Frames: Dark Bronze.

** NOTE TO SPECIFIER ** Retain one of the following flange types and delete types not required for project.

        1. Frame Flange Configuration: 1-3/8 Inches (35 mm) Flange Setback.

        2. Frame Flange Configuration: 1 inch (25 mm) Flange Setback with Stucco Key.

        3. Frame Flange Configuration: Replacement Configuration.

        4. Weatherstripping:

          1. Active Panel: Dual pile polypropylene weatherstrip full perimeter of frame and at meeting stile.

          2. Stationary Panel: Felt weatherstrip at head, stationary side and sill.

      1. Glazing:

** NOTE TO SPECIFIER ** Delete certification requirements not required.

        1. General: Tempered insulating glass units certified through the Insulating Glass Certification Council as conforming to the requirements of IGCC. Provide dual sealed units consisting of polyisobutylene primary seal and silicone secondary seal. Provide metal spacers with bent or soldered corners.

        2. General: Tempered insulating glass units certified through the Insulating Glass Manufacturers Alliance of Canada (IGMAC) conforming to the requirements of Canadian General Standards Board CAN/CGSB 12.8. Provide dual sealed units consisting of polyisobutylene primary seal and silicone secondary seal. Provide metal spacers with bent or soldered corners.

** NOTE TO SPECIFIER ** Select between the following standard glazing options. Consult an Andersen representative for additional glazing options. In addition to complying with safety glazing requirements, tempered glass may be required because of window size and wind load. Consult Andersen Corporation for assistance in specifying the appropriate glazing type.

        1. Dual-Pane Insulating Glass Units:

          1. Glass: Tempered insulating glass units consisting of an outboard and inboard lite of clear tempered glass conforming to ASTM C1048, Type 1, Class 1, q3, Kind FT.

** NOTE TO SPECIFIER ** Where patterned glass is required for project, delete paragraph above and retain paragraph below with appropriate patterned glass type. Delete types not required for project.

          1. Glass: Tempered insulating glass units consisting of an outboard lite of clear tempered glass conforming to ASTM C1048, Type 1, Class 1, q3, Kind FT and the following patterned glass:

            1. Inboard Pattern Glass Lite: Cascade.

            2. Inboard Pattern Glass Lite: Fern.

            3. Inboard Pattern Glass Lite: Obscure.

            4. Inboard Pattern Glass Lite: Reed.

          2. Air Space: 3/4 inch (19 mm).

          3. Filling: Fill space between glass lites with argon gas blend.

        1. SmartSun™Low-E Glass, Low SHGC, Argon Gas Blend Filled Insulating Glass Units:

          1. Glass: Tempered insulating glass units consisting of an outboard and inboard lite of clear tempered glass conforming to ASTM C1048, Type 1, Class 1, q3, Kind FT.

** NOTE TO SPECIFIER ** Where patterned glass is required for project, Delete paragraph above and retain paragraph below with appropriate patterned glass type. Delete types not required for project.

          1. Glass: Tempered insulating glass units consisting of an outboard lite of clear tempered glass conforming to ASTM C1048, Type 1, Class 1, q3, Kind FT and the following patterned glass:

            1. Inboard Pattern Glass Lite: Cascade.

            2. Inboard Pattern Glass Lite: Fern.

            3. Inboard Pattern Glass Lite: Obscure.

            4. Inboard Pattern Glass Lite: Reed.

          2. Air Space: 3/4 inch (75 mm).

          3. SmartSun Low-E Glass Coating: Magnetron sputtering vapor deposition (MSVD) Low-E coating applied to the No. 2 surface.

          4. Filling: Fill space between glass lites with argon gas blend.

        1. High-Performance™ Low-E4® SmartSun™ Glass, Low SHGC, Argon Gas Blend Filled Insulating Glass Units:

          1. Glass: Tempered insulating glass units consisting of an outboard and inboard lite of clear tempered glass conforming to ASTM C1048, Type 1, Class 1, q3, Kind FT.

** NOTE TO SPECIFIER ** Where patterned glass is required for project, Delete paragraph above and retain paragraph below with appropriate patterned glass type. Delete types not required for project.

          1. Glass: Tempered insulating glass units consisting of an outboard lite of clear tempered glass conforming to ASTM C1048, Type 1, Class 1, q3, Kind FT and the following patterned glass:

            1. Inboard Pattern Glass Lite: Cascade.

            2. Inboard Pattern Glass Lite: Fern.

            3. Inboard Pattern Glass Lite: Obscure.

            4. Inboard Pattern Glass Lite: Reed.

          2. Air Space: 3/4 inch (19 mm).

          3. Magnetron sputtering vapor deposition (MSVD) TiO2 coating applied to the No. 1 surface.

          4. High-Performance™ Low-E4 Sun Glass Coating: Magnetron sputtering vapor deposition (MSVD) Low-E coating applied to the No. 2 surface.

          5. Filling: Fill space between glass lites with argon gas blend.

        1. STC Glass: Manufacturer's proprietary sound transmission class glass type.

      1. Hardware:

        1. Roller Assembly: Provide operating panels with adjustable roller assembly consisting of self-lubricating tandem wheels operating on ball bearings. Provide 2-tandem rollers for each operating panel.

** NOTE TO SPECIFIER ** 6-pin key cylinder is optional. Retain, edit, or delete the following paragraph to suit project requirements.

        1. Lock Lever: Die cast zinc reach- out hook bolt locking mechanism. Design lock to prevent automatic locking when door is closed.

** NOTE TO SPECIFIER ** Retain one of the following two options per project requirements.

          1. Provide blank cover at exterior.

          2. Provide 6-pin keyed cylinder.

** NOTE TO SPECIFIER ** Optional auxiliary and 6-pin key cylinder exterior keyed locks shipped separately.

        1. Gliding Interior Handle: Die Cast aluminum operating handle pull with white powder-coated finish:

        2. Gliding Exterior Handle: Die cast aluminum operating handle pull with powder-coated finish to match exterior finish.

** NOTE TO SPECIFIER ** Auxiliary Foot locks are optional on 2 and 4 panel doors. Delete paragraph if not required.

        1. Foot Lock: Provide operating panels with auxiliary foot lock consisting of a spring loaded plunger that engages a grommet in sill. Provide auxiliary foot locks in the following finish or color:

          1. Color: White.

      1. Joining Systems

** NOTE TO SPECIFIER ** Andersen windows strongly recommends consultation with an experienced structural engineer, architect, or contractor and a local Andersen representative when specifying Andersen joining systems. Consult an Andersen representative for joining options when joining Impact Resistant window products.
** NOTE TO SPECIFIER ** If required for project, retain one of the 1-way or 2-way combinations below and related subparagraph. Delete combinations not required for project.


        1. LVL Reinforced Joining - 1-way Combination: Provide 4-9/16 inch (116 mm) by 3/4 inch (19 mm) laminated veneer lumber (LVL) joining with extruded anodized aluminum trim receptor end cap.

          1. Provide corrosion resistant screws and bolts for fastening reinforcement members to wood frame and fastening end brackets to reinforcement members.

        2. Gusset Plates: Galvanized steel plates as recommended by door manufacturer for specific application.

        3. Fasteners: Corrosion-resistant screws as provided by door manufacturer for fastening reinforcement members and gusset plates to wood frame. Other fasteners are provided by door installer.

        4. Sealant: As recommended by door manufacturer.

        5. Exterior Vinyl Trim Strips: Provide for each joining method used.

          1. Color: Match door exterior color.

** NOTE TO SPECIFIER ** Specify subordinate or secondary items that aid and assist primary products specified above or are necessary for preparation or installation of those items.

      1. Accessories:

** NOTE TO SPECIFIER ** Coordinate specifications for grille material of adjacent unit for joined units of different types. Standard grille width is 3/4 inch (19 mm). Hardwood maple grilles are provided for picture windows and are available for other window types on special order. Consult an Andersen representative for additional grille options.

      1. Grilles:

        1. Finelight™ Grilles: Provide contour profile aluminum muntin bars permanently mounted within insulating glass unit where indicated on Drawings.

        2. Grille Intersections: ABS concealed plastic connectors with nylon end keepers.

** NOTE TO SPECIFIER ** Retain project required finish subparagraph below. Delete subparagraphs not required. Specify if interior color is different than exterior color.

        1. Exterior and Interior Surface: White color painted finish.

        2. Exterior and Interior Surface: Sandtone color painted finish.

        3. Exterior and Interior Surface: Terratone® color painted finish.

        4. Exterior and Interior Surface: Cocoa Bean color painted finish.

        5. Exterior and Interior Surface: Dark Bronze color painted finish.

        6. Width: 3/4 inch (19 mm).

** NOTE TO SPECIFIER ** Retain required Grille width above or below. Delete subparagraphs not required.

        1. Width: 1 inch (25 mm).

        2. Pattern as indicated on Drawings.

** NOTE TO SPECIFIER ** Delete if not required.

      1. Gliding Insect Screens: Provide gliding patio doors with gliding insect screen installed on exterior.

        1. Insect Screen Door Frame: 0.040 inch (1 mm) roll formed aluminum frame with chromate conversion coating in the following polyester painted color.

** NOTE TO SPECIFIER ** Retain project required color subparagraph below. delete subparagraphs not required.

          1. Color: White.

          2. Color: Sandtone.

          3. Color: Terratone®.

          4. Color: Cocoa Bean.

          5. Color. Dark Bronze

        1. Insect Screen Cloth: 18 by 16 glass fiber mesh, charcoal color finish.

        2. Rollers: Insect screen doors operate on injection molded bottom rollers with self contained leveling adjusters engaged in sill track.

        3. Operating Handles: Polycarbonate operating handles to receive locking mechanism in the following color.

** NOTE TO SPECIFIER ** Retain project required color subparagraph below. delete subparagraph not required.

          1. Color: White.

          2. Color: Black.

** NOTE TO SPECIFIER ** Describe items that must be shop manufactured, fabricated, or assembled before being delivered to the site.

      1. Shop Fabrication:

        1. Door Stiles and Rails: Fibrex® material frame member co-extruded interior and exterior colored cap stock and with co-extruded flanges for installation.

        2. Sill: 0.100 inch (2.5 mm) PVC extrusion.

        3. Weatherstripping: Factory-applied to unit frame.

        4. Glazing: Factory-glazed with glazing sealant and interior trim stops.

  1. EXECUTION

    1. EXAMINATION

      1. Site Verification of Conditions: Verify that site conditions are acceptable for installation of units, including the following:

        1. Concrete surfaces are dry and free of excess mortar, rocks, sand, and other construction debris.

** NOTE TO SPECIFIER ** Retain subparagraph below for masonry construction.

        1. Masonry openings are square and dimensions are correct.

** NOTE TO SPECIFIER ** Retain subparagraph below for wood framing.

        1. Rough openings are square and dimensions are correct.

          1. Sill plates are level.

          2. Wood frame walls are dry, clean, sound, and well nailed or glued, free of voids and without offsets at joints.

          3. Nail heads are driven flush with surfaces in openings and within 3 inches (75 mm) of rough opening.

      1. Do not proceed with installation of units until unacceptable conditions are corrected.

      2. If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding.

    1. PREPARATION

      1. Clean surfaces thoroughly prior to installation.

      2. Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions.

      3. General:

        1. Remove unit components, parts, accessories, and installation guides from carton.

        2. Inspect unit components and verify that components are not damaged and that parts are included before disposing of carton.

** NOTE TO SPECIFIER ** Delete if not required.

        1. Field-assemble multiple units before installation in accordance with manufacturer's installation guide.

      1. Interface With Other Work:

        1. Perform installation in accordance with Manufacturer's instructions.

        2. Install units level, plumb, square, true to line, without distortion, anchored securely in place to structural support, and in proper relation to wall flashing and other adjacent construction.

        3. Separate aluminum and other corrodible surfaces from sources of corrosion or electrolytic action at points of contact with other materials.

        4. Install insulation in shim space around unit perimeter to maintain continuity of building insulation. Do not overfill.

        5. Hold back exterior siding or other finish materials from edge of unit to allow for expansion and contraction and installation of proper joint sealant with backing materials. Seal perimeter of unit after exterior finish is applied per requirements of Division 07 "Joint Sealants" Section.

        6. Extend vapor barrier to interior face of unit frame and attach.

        7. Finish interior units per requirements specified in related sections. Refer to, and comply with, additional requirements in manufacturer's installation guides.

        8. Install optional hardware and unit accessories after cleaning.

** NOTE TO SPECIFIER ** Specify allowable variations below.

      1. Site Tolerances:

        1. Adjust operation, insect screens, hardware, and accessories for a tight fit at contact points and weatherstripping for smooth operation and weathertight closure.

    1. INSTALLATION

      1. General:

        1. Comply with instructions and recommendations of unit manufacturer.

        2. Remove unit components, parts, accessories, and installation guides from carton.

        3. Inspect unit components and verify that components are not damaged and that parts are included before disposing of carton.

        4. Shop-assemble multiple units before installation per manufacturer's installation guides.

** NOTE TO SPECIFIER ** Retain subparagraph above for shop-assembled units. Retain subparagraph below for field-assembled units.

        1. Field-assemble multiple units before installation per manufacturer's installation guides.

** NOTE TO SPECIFIER ** Delete if not required.

    1. FIELD TESTING

** NOTE TO SPECIFIER ** Coordinate article below with conditions of the contract and with division 01 quality control. Testing equipment shall be calibrated per Section 9 of ASTM E1105: Standard Test Method for Field Determination of Water Penetration of Installed Exterior Windows, Skylights, Doors and Curtain Walls, by Uniform or Cyclic Static Air Pressure Difference, where the water test pressure shall be run at 2/3 (0.667) of the water test pressure used to achieve the products rated design pressure. The numbers of products tested shall be agreed and written in the project specification and shall not exceed 1 percent of the total number of openings unless specified otherwise.

      1. General: Test units per the following procedures:

        1. Inspect units and verify installation per Manufacturer's instructions.

        2. For products installed less than 6 months, comply with AAMA 502-08 Voluntary Specification for Field Testing of Windows and Sliding Glass Doors, Procedure B.

        3. For products installed longer than 6 months, comply with AAMA 511-08: Voluntary Guideline for Forensic Water Penetration Testing of Fenestration Products. If test indicates that field testing of units is necessary, test product as indicated in paragraph 1 above.

        4. Do not proceed with installation of additional units until unacceptable conditions are corrected.

** NOTE TO SPECIFIER ** Specify the final action required to clean installed equipment or other completed work to properly function or perform. Coordinate article below with Division 01 Execution Requirements (Cleaning) Section and specific project requirements.

    1. CLEANING

      1. Clean units using cleaning material and methods specifically recommended by window manufacturer.

      2. Remove excess sealants, glazing materials, dirt, and other substances.

      3. Avoid damaging protective coatings and finishes.

      4. Protect unit surfaces from masonry cleaning solution that could damage insulation glass panels or hardware.

      5. Remove debris from work site and properly dispose of debris.

    2. PROTECTION

      1. Protect installed products until completion of project.

      2. Touch-up, repair or replace damaged products before Substantial Completion.

END OF SECTION