Sep 2019 I draft d1 automotive industry standards


Phase C Indirect exposure to flame



Download 1.31 Mb.
View original pdf
Page53/62
Date13.07.2021
Size1.31 Mb.
#57062
1   ...   49   50   51   52   53   54   55   56   ...   62
AIS 156
AIS 156
Phase C Indirect exposure to flame


Annex E
68 3.7.4. Phase D End of test (Figure 4) The burning pan covered with the screen shall be moved back to the position described in phase A. No extinguishing of the tested-device shall be done. After removal of the pan the tested-device shall be observed until such time as the surface temperature of the tested-device has decreased to ambient temperature or has been decreasing fora minimum of 3 hours.
Figure 4 Phase D End of test


Annex E – Appendix
69
Annex E - Appendix
Dimension and technical data of firebricks
Fire resistance
(Seger-Kegel) SK 30
Al2O3 content
30 - 33 percent Open porosity (Po
20 - 22 percent vol. Density
1,900 - 2,000 kg/m3 Effective holed area
44.18 percent



Download 1.31 Mb.