LOW Not Selected

MOD PE-17

HIGH PE-17



PE-18 LOCATION OF INFORMATION SYSTEM COMPONENTS


Control: The organization positions information system components within the facility to minimize potential damage from [Assignment: organization-defined physical and environmental hazards] and to minimize the opportunity for unauthorized access.

Supplemental Guidance: Physical and environmental hazards include, for example, flooding, fire, tornados, earthquakes, hurricanes, acts of terrorism, vandalism, electromagnetic pulse, electrical interference, and other forms of incoming electromagnetic radiation. In addition, organizations consider the location of physical entry points where unauthorized individuals, while not being granted access, might nonetheless be in close proximity to information systems and therefore increase the potential for unauthorized access to organizational communications (e.g., through the use of wireless sniffers or microphones). Related controls: CP-2, PE-19, RA-3.

Control Enhancements:

  1. location of information system components | facility site

The organization plans the location or site of the facility where the information system resides with regard to physical and environmental hazards and for existing facilities, considers the physical and environmental hazards in its risk mitigation strategy.

Supplemental Guidance: Related control: PM-8.

References: None.

Priority and Baseline Allocation:

P3

LOW Not Selected

MOD Not Selected

HIGH PE-18



PE-19 INFORMATION LEAKAGE


Control: The organization protects the information system from information leakage due to electromagnetic signals emanations.

Supplemental Guidance: Information leakage is the intentional or unintentional release of information to an untrusted environment from electromagnetic signals emanations. Security categories or classifications of information systems (with respect to confidentiality) and organizational security policies guide the selection of security controls employed to protect systems against information leakage due to electromagnetic signals emanations.

Control Enhancements:

  1. information leakage | national emissions / tempest policies and procedures

The organization ensures that information system components, associated data communications, and networks are protected in accordance with national emissions and TEMPEST policies and procedures based on the security category or classification of the information.

References: FIPS Publication 199.

Priority and Baseline Allocation:

P0

LOW Not Selected

MOD Not Selected

HIGH Not Selected



PE-20 ASSET MONITORING AND TRACKING


Control: The organization:

  1. Employs [Assignment: organization-defined asset location technologies] to track and monitor the location and movement of [Assignment: organization-defined assets] within [Assignment: organization-defined controlled areas]; and

  2. Ensures that asset location technologies are employed in accordance with applicable federal laws, Executive Orders, directives, regulations, policies, standards, and guidance.

Supplemental Guidance: Asset location technologies can help organizations ensure that critical assets such as vehicles or essential information system components remain in authorized locations. Organizations consult with the Office of the General Counsel and the Senior Agency Official for Privacy (SAOP)/Chief Privacy Officer (CPO) regarding the deployment and use of asset location technologies to address potential privacy concerns. Related control: CM-8.

Control Enhancements: None.

References: None.

Priority and Baseline Allocation:

P0

LOW Not Selected

MOD Not Selected

HIGH Not Selected


Directory: publications
publications -> Acm word Template for sig site
publications ->  Preparation of Papers for ieee transactions on medical imaging
publications -> Adjih, C., Georgiadis, L., Jacquet, P., & Szpankowski, W. (2006). Multicast tree structure and the power law
publications -> Swiss Federal Institute of Technology (eth) Zurich Computer Engineering and Networks Laboratory
publications -> Quantitative skills
publications -> Multi-core cpu and gpu implementation of Discrete Periodic Radon Transform and Its Inverse
publications -> List of Publications Department of Mechanical Engineering ucek, jntu kakinada
publications -> 1. 2 Authority 1 3 Planning Area 1
publications -> Sa michelson, 2011: Impact of Sea-Spray on the Atmospheric Surface Layer. Bound. Layer Meteor., 140 ( 3 ), 361-381, doi: 10. 1007/s10546-011-9617-1, issn: Jun-14, ids: 807TW, sep 2011 Bao, jw, cw fairall, sa michelson

Download 5.8 Mb.

Share with your friends:
1   ...   109   110   111   112   113   114   115   116   ...   186




The database is protected by copyright ©ininet.org 2024
send message

    Main page