Ballast
systems in the cargo area
Ventilation
and gas-freeing
Ventilation of cargo and ballast pump rooms in the cargo area:
Pump rooms are to be ventilated by mechanically driven fans of the extraction type.
Fresh air is to be induced into the pump room from above.
These ventilation systems shall not be connected to those of other spaces.
The exhaust duct is to be so installed that its suction opening is close to the bottom of the pump room.
An emergency suction opening is to be located about 2 m above the pump room floor.
This opening is to be fitted with a means of closing which can also be operated from the main deck.