Electrical Installations

  • Insulation monitoring
  • Insulation fault. Device(s) to continuously monitoring the insulation earth shall be installed for both insulated and earthed distribution systems.
  • An audible and visual alarm shall be given at a manned position in the event of an abnormally low level of insulation resistance and or high level of leakage current.
  • Electrical equipment and wiring are in general not to be installed in hazardous areas.
  • Where essential for operational purposes, arrangement of electrical installations in hazardous areas are to the satisfaction of the administrations.

Electrical Installations

  • Area classification is a method of analyzing and classifying the areas where explosive gas atmospheres may occur.
  • The object of the classification is to allow the selection of electrical apparatus able to be operated safely in these areas.
  • In order to facilitate the selection of appropriate electrical apparatus an the design of suitable electrical installations, hazardous areas are divided into zones 0, 1 and 2 according to the principles of the standards of International Electro-technical Commission(IEC).
  • A space with opening to an adjacent hazardous area on open deck, may be made into a less hazardous or non-hazardous space, by means of overpressure.