U. S. Department of Transportation



Download 6.47 Mb.
Page24/60
Date02.02.2017
Size6.47 Mb.
#15690
1   ...   20   21   22   23   24   25   26   27   ...   60



U.S. DEPARTMENT OF TRANSPORTATION

MASTER MINIMUM EQUIPMENT LIST

FEDERAL AVIATION ADMINISTRATION


AIRCRAFT:

GULFSTREAM G-V, GV-SP,

GV-SP (G550), GV-SP (G500),

GIV-X, GIV-X (G450),

GIV-X (G350)


REVISION NO: 7

DATE: 02/04/2010



PAGE NO:

26-1


1. SYSTEM,

SEQUENCE NUMBERS & ITEM



REPAIR CATEGORY




2. NUMBER INSTALLED




3. NUMBER REQUIRED FOR DISPATCH




4. REMARKS OR EXCEPTIONS

26

FIRE PROTECTION





































1.

Portable Fire Extinguishers

D

-

-

Any in excess of those required by 14 CFR may be inoperative or missing provided:

  1. Inoperative fire extinguisher is tagged inoperative, removed from the installed location, and placed out of sight so it cannot be mistaken for a functional unit, and

  2. Required distribution is maintained.

|























2.

Wing Overheat Warning Systems

C

2

0

Except for ER operations, may be inoperative provided:

  1. Wing Anti-Ice is not used, and

  2. Airplane is not operated in known or forecast icing conditions.

























3.

APU Fire Detection System

C

1

0

(M) Except for ER operations, may be inoperative provided:

  1. APU is not used, and

  2. APU CONT #1 and APU CONT #2 circuit breakers are pulled and collared.




























U.S. DEPARTMENT OF TRANSPORTATION

MASTER MINIMUM EQUIPMENT LIST

FEDERAL AVIATION ADMINISTRATION


AIRCRAFT:

GULFSTREAM G-V, GV-SP,

GV-SP (G550), GV-SP (G500),

GIV-X, GIV-X (G450),

GIV-X (G350)


REVISION NO: 7a

DATE: 11/08/2010



PAGE NO:

26-2


1. SYSTEM,

SEQUENCE NUMBERS & ITEM



REPAIR CATEGORY




2. NUMBER INSTALLED




3. NUMBER REQUIRED FOR DISPATCH




4. REMARKS OR EXCEPTIONS

26

FIRE PROTECTION





































4.

Rear Baggage Compartment Smoke Detector Systems

C

-

0

May be inoperative provided:

  1. Internal baggage door remains OPEN, and

  2. Airplane is operated at or below FL 400.































C

-

0

May be inoperative provided:

  1. Rear baggage compartment is not used,

  2. Internal baggage door remains CLOSED,

  3. Flight crew investigates baggage compartment for possible fire in the event the “BAG EER HOT” message displays, and

  4. Airplane is operated in accordance with AFM Limitations.




























U.S. DEPARTMENT OF TRANSPORTATION

MASTER MINIMUM EQUIPMENT LIST

FEDERAL AVIATION ADMINISTRATION


AIRCRAFT:

GULFSTREAM G-V, GV-SP,

GV-SP (G550), GV-SP (G500),

GIV-X, GIV-X (G450),

GIV-X (G350)


REVISION NO: 6

DATE: 07/24/07



PAGE NO:

26-3


1. SYSTEM,

SEQUENCE NUMBERS & ITEM



REPAIR CATEGORY




2. NUMBER INSTALLED




3. NUMBER REQUIRED FOR DISPATCH




4. REMARKS OR EXCEPTIONS

26

FIRE PROTECTION





































5. ***

Lavatory Smoke Detection Systems

C

-

-

(M)(O) For each lavatory, the lavatory smoke detection system may be inoperative provided:

  1. Lavatory waste receptacle is empty,

  2. Associated lavatory door is LOCKED, CLOSED and placarded, “INOPERATIVE-DO NOT ENTER”, and

  3. Lavatory is used only by crewmember.








































NOTE 1: These provisos are not intended to prohibit lavatory use or inspections by crewmembers.








































NOTE 2: Lavatory smoke detection system is not required for all-cargo operations.




























U.S. DEPARTMENT OF TRANSPORTATION

MASTER MINIMUM EQUIPMENT LIST

FEDERAL AVIATION ADMINISTRATION


AIRCRAFT:

GULFSTREAM G-V, GV-SP,

GV-SP (G550), GV-SP (G500),

GIV-X, GIV-X (G450),

GIV-X (G350)


REVISION NO: 6

DATE: 07/24/07



PAGE NO:

26-4


1. SYSTEM,

SEQUENCE NUMBERS & ITEM



REPAIR CATEGORY




2. NUMBER INSTALLED




3. NUMBER REQUIRED FOR DISPATCH




4. REMARKS OR EXCEPTIONS

26

FIRE PROTECTION





































6. ***

Lavatory Fire Extinguisher Systems

C

-

-

For each lavatory, the lavatory fire extinguisher system may be inoperative provided Lavatory Smoke Detector system is operative.































C

-

-

(M)(O) For each lavatory, the lavatory fire extinguisher system may be inoperative provided:

  1. Lavatory waste receptacle is empty,

  2. Associated lavatory door is LOCKED, CLOSED and placarded, “INOPERATIVE – DO NOT ENTER”, and

  3. Lavatory is used only by crewmembers.








































NOTE 1: These provisos are not intended to prohibit lavatory use or inspections by crewmembers.








































NOTE 2: A lavatory fire extinguisher system is not required for all-cargo operations.

























7. ***

Galley Smoke Detection Systems

D

-

0




























8. ***

Galley Fire Extinguishing Systems

D

-

0