General text for tender (recommendations) for Pilkington Profilit™ Contents Page



Download 50.63 Kb.
Date11.10.2016
Size50.63 Kb.
#34

General text for tender (recommendations)




General text for tender (recommendations)
for Pilkington Profilit™


Contents Page

I) Standard profile (NP) glazing with Pilkington Profilit™ frame profiles
installed vertically as a row of windows 2

II) Special profile (SP) glazing with Pilkington Profilit™ frame profiles
installed vertically as a row of windows 5

III) Sports hall glazing systems as per DIN 18032 with the Pilkington Profilit™
profiles K22/60/7, K25/60/7 and K32/60/7 and Pilkington Profilit™
frame profiles installed vertically as row of windows 8

IV) Pivoted casements, for installation in Pilkington Profilit™
glass walls (standard profiles - series 60) 11

V) Hinged wing units for installing in Pilkington Profilit™ glass walls
(special profiles - series 83) 12


Recommended text for tender

I) General text for tender (recommendations) for Pilkington Profilit™ standard profile (NP) glazing with Pilkington Profilit™ frame profiles installed vertically as a row of windows

Item 1) running metres side- or top- Pilkington Profilit™ frame profiles made of aluminium, (AlMgSi0.5) with numbers 950S, 950N, 963 (950SL with ventilation) or thermally broken 820, anodised as per E6/EV 1, with a coating thickness of 20 my, RAL-coated or mill finished with a hardening characteristic of F22 and a material thickness of 2.3 mm respectively 2.0 mm. Supply and expert installation by taking into account the arrangement of expansion joints as well as the sealing of butt- and corner joints . The price quoted includes all butt- and corner joints as well as the fixing of profiles to substructure. All relevant standards and regulations require compliance if applicable.


€/running metre .......................................
Item 2) running metres supply and expert installation of lower Pilkington Profilit™ frame profiles with numbers 951, 961, 961/50, 961/80, 961/100, 961/120, 961/150, 961/180 or thermally broken 821, 821/50, 821/80, 821/100, 821/120, 821/150, 821/180, otherwise as described under Item 1). With or without** base gasket no. 170. In case of frames with integrated window sills frames with drainage slits and 40 mm drip edging. New thermally broken frame with drainage slit.
€/running metre .......................................
Item 3) m2 expert glazing of window area in form of one or several openings with dimensions: ................. m wide x ................. m high according to recommendations of Bauglasindustrie GmbH in Schmelz/Saar whilst giving due consideration to the load ................. kN/m2 (wind load, self weight, etc.) for open or closed buildings, using single- or double* Pilkington Profilit™ glazing. Glazing encompasses Pilkington Profilit™ glass types K22, K25, K32 or K50 with or without non-corroding longitudinal wire inserts and the requisite Pilkington Profilit™ glass-holding profiles made of highly impact-resistant hard PVC, nos. 961/1 and 962/1 (single glazed) or 961/2 and 962/2* (double glazed). The expert sealing of the glass units to one another and to the frame using e.g. Pilkington Profilit™ SIL is also included in the price quoted. Glass transportation as well as the cleaning and cutting of the glasses must also be taken into account when quoting. Any alternative product used must be of the same high quality, UV-resistant, weatherproof, incombustible and offer high light transparency.
Ug - value = 2.8 W/m2 €/m2 .......................................

Supplement for Pilkington Profilit™ ‘Antisol’


€/m2 .......................................
Supplement for Pilkington Profilit™ ‘Plus 1.7’
€/m2 .......................................
Supplement for Pilkington Profilit™ ‘Amethyst’
€/m2 .......................................
Supplement for Pilkington Profilit™ ‘Clear’
€/m2 .......................................
Supplement for Pilkington Profilit™ T
€/m² ........................................
Supplement for Pilkington Profilit™ T H
€/m² ........................................
Supplement for Pilkington Profilit™ T Color
€/m² ........................................
Supplement for Pilkington Profilit™ T Color H
€/m² ........................................

* Delete non-applicable item.

** Base gasket no. 170 can only be used with non-thermally broken

frames.
Please take into account our Pilkington Profilit™ programme because not all products and combinations are available in series, as well as the special product specification and application requirements for our thermally toughened Pilkington Profilit™ T products.




Note:


Separate tenders should be prepared for sealing between frame and substructure as well as for any padded profiles (nos. 166 and 165). The same applies to the installation of window sills and window drips. Furthermore, details need to be indicated concerning: type of structure, location of building site, conditions on building site, breast height of glazing measured from ground level, scaffolding and usage of same, provision of assistance to help with unloading etc., times when work is to be performed and when interrupted, supply of electrical power, type of breast and lintel structure, material ... (should be indicated) with due consideration given to horizontal wind forces; ventilation shutter units should be included as supplementary items. Pilkington Profilit™ glass and frame profiles must be protected from soiling (e.g. from mortar, etc.) while construction work is in progress. Special mention must be made of any potential application of workplace- and energy saving regulations.

II) General text for tender (recommendations) for Pilkington Profilit™ special profile (SP) glazing systems with the Pilkington Profilit™ frame profiles installed vertically as row of windows.

Item 1) running metres side-or top- Pilkington Profilit™ frame profiles made of aluminium, (AIMgSi0.5) with the numbers 980, or thermally broken 810, anodised as per E6/EV 1 with a coating thickness of 20 my, RAL-coated or mill finished with a hardening characteristic of F22 and a material thickness of 3.0 mm respectively 2.0 mm. Supply and expert installation by taking into account the arrangement of expansion joints as well as the sealing of butt- and corner joints. The price quoted includes all butt- and corner joints as well as the fixing of profiles to substructure. All relevant standards and regulations require compliance if applicable.


€/running metre .......................................
Item 2) running metres supply and expert installation of lower Pilkington Profilit™ frame profiles with numbers 981, 981/50 or 981/100 or thermally broken 811, 811/50, 811/80, 811/100, 811/120, 811/150, 811/180, otherwise as described under Item 1). Thickness: 2.0 mm; hardening characteristic: F22. With or without** base gasket no. 170. In case of frames with integrated window sills frames with drainage slits and 40 mm drip edging. New thermally broken frame with drainage slit.
€/running metre .......................................
Item 3) m2 expert glazing for window area in form of one or several openings with the following dimensions: ................. m wide x ................. m high according to recommendations of Bauglasindustrie GmbH in Schmelz/Saar whilst giving due consideration to the load ................. kN/m2 (wind load, self weight, etc.) for open or closed buildings, using single- or double-shell* Pilkington Profilit™ glazing. Glazing encompasses Pilkington Profilit™ glass types K22/60/7, K25/60/7 or K32/60/7 with or without non-corroding longitudinal wire inserts and the requisite Pilkington Profilit™ glass-holding profiles made of highly impact-resistant hard PVC, nos. 981/1 and 980/1 (single glazed) or 981/2 and 980/2* (double glazed).
The expert sealing of the glass units to one another and to the frame using e.g. Pilkington Profilit™ SIL is also included in the price quoted. Glass transportation as well as the cleaning and cutting of the glass must also be taken into account when quoting. Any alternative product used must be of the same high quality, UV-resistant, weatherproof, incombustible and offer high light transparency.
Ug - value = 2.8 W/m2 €/m2 .......................................

Supplement for Pilkington Profilit™ ‘Antisol’


€/m2 .......................................
Supplement for Pilkington Profilit™ ‘Plus 1.7’
€/m2 .......................................
Supplement for Pilkington Profilit™ ‘Amethyst’
€/m2 .......................................
Supplement for Pilkington Profilit™ ‘Clear’
€/m2 .......................................
Supplement for Pilkington Profilit™ T
€/m² ........................................
Supplement for Pilkington Profilit™ T H
€/m² ........................................
Supplement for Pilkington Profilit™ T Color
€/m² ........................................
Supplement for Pilkington Profilit™ T Color H
€/m² ........................................
* Delete non-applicable item.

** Base gasket no. 170 can only be used with non-thermally broken

frames.

Please take into account our Pilkington Profilit™ Programme because not all products and combinations are available in series, as well as the special product specification and application requirements for our thermally toughened Pilkington Profilit™ T products.






Note:


Separate tenders should be prepared for sealing between frame and substructure. The same applies to the installation of window sills and window drips. Furthermore, details need to be indicated concerning: type of structure, location of building site, conditions on building site, breast height of glazing measured from ground level, scaffolding and usage of same, provision of assistance to help with unloading etc., times when work is to be performed and when interrupted, supply of electrical power, type of breast and lintel structure, material .................................. (should be indicated) with due consideration given to horizontal wind forces; ventilation shutter units should be included as supplementary items. Pilkington Profilit™ glass and frame profiles must be protected from soiling (e.g. from mortar, etc.) while construction work is in progress. Special mention must be made of any potential application of workplace- and energy saving regulations.



III) General text for tender (recommendations) for Pilkington Profilit™ sports hall glazing systems as per DIN 18032 with the Pilkington Profilit™ profiles K22/60/7, K25/60/7 and K32/60/7 and Pilkington Profilit™ frame profiles installed vertically as row of windows.

Item 1) running metres side-or top- Pilkington Profilit™ frame profiles made of aluminium, (AIMgSi0.5) with the numbers 980, or thermally broken 810, anodised as per E6/EV 1 with a coating thickness of 20 my, RAL-coated or mill finished with a hardening characteristic of F22 and a material thickness of 3.0 mm respectively 2.0 mm. Supply and expert installation by taking into account the arrangement of expansion joints as well as the sealing of butt- and corner joints. The price quoted includes all butt- and corner joints as well as the fixing of profiles to substructure. All relevant standards and regulations require compliance if applicable.


€/running metre .......................................
Item 2) running metres supply and expert installation of lower Pilkington Profilit™ frame profiles with numbers 981, 981/50 or 981/100 or thermally broken 811, 811/50, 811/80, 811/100, 811/120, 811/150, 811/180, otherwise as described under Item 1). Thickness: 2.0 mm; hardening characteristic: F22. With or without** base gasket no. 170. In case of frames with integrated window sills frames with drainage slits and 40 mm drip edging. New thermally broken frame with drainage slit.
€/running metre .......................................
Item 3) m2 expert glazing for sports hall window area in form of one or several openings with the following dimensions: ................. m wide x ................. m high according to recommendations of Bauglasindustrie GmbH in Schmelz/Saar whilst giving due consideration to the load ................. kN/m2 (wind load, self weight, etc.) for open or closed buildings, using double-shell Pilkington Profilit™ sports hall glass K22/60/7, K25/60/7 or K32/60/7 without longitudinal wires.
The fixed price includes Pilkington Profilit™ insert profiles made of highly impact-resistant hard PVC, nos. 981/2 and 980/2 as well as throughout, padded soft PVC profiles for glass flanges nos. 165 and 166. PVC profiles nos. 981/1 and 980/1* can be used for non-ball-impact-resistant, single glazing with profiles K22/60/7, K25/60/7 or K32/60/7 with or without longitudinal wires which are available from Bauglasindustrie GmbH.
The expert sealing of the glass units to one another and to the frame using e.g. Pilkington Profilit™ SIL is also included in the price quoted. Glass transportation as well as the cleaning and cutting of the glass must also be taken into account when quoting. Any alternative product used must be of the same high quality, UV-resistant, weatherproof, incombustible and offer high light transparency.
Ug - value = 2.8 W/m2 €/m2 .......................................

Supplement for Pilkington Profilit™ ‘Antisol’


€/m2 .......................................
Supplement for Pilkington Profilit™ ‘Plus 1.7’
€/m2 .......................................
Supplement for Pilkington Profilit™ ‘Amethyst’
€/m2 .......................................
Supplement for Pilkington Profilit™ ‘Clear’
€/m2 .......................................

* Delete non-applicable item.

** Base gasket no. 170 can only be used with non-thermally broken

frames.


Please take into account our Pilkington Profilit™ Programme because not all products and combinations are available in series.


Note:


All relevant national standards and regulations for sports halls have to be taken into account.
Separate tenders should be prepared for sealing between frame and substructure. The same applies to the installation of window sills and window drips. Furthermore, details need to be indicated concerning: type of structure, location of building site, conditions on building site, breast height of glazing measured from ground level, scaffolding and usage of same, provision of assistance to help with unloading etc., times when work is to be performed and when interrupted, supply of electrical power, type of breast and lintel structure, material .................................. (should be indicated) with due consideration given to horizontal wind forces; ventilation shutter units should be included as supplementary items. Pilkington Profilit™ glass and frame profiles must be protected from soiling (e.g. from mortar, etc.) while construction work is in progress. Special mention must be made of any potential application of workplace- and energy saving regulations.

Since regulations give no guidance with specific regard to profile-type glazing surface, the following procedure has been adopted up until now in terms of the size of the glazed area (providing no other procedure has been prescribed):


a) if the architect concerned is inviting tenders for an approximate area (e.g. approx. 100m² glass), the height nearest to the one required that can be divided by 25 cm should be taken for calculation purposes, whereas the width calculation should be based on the full width of the given glass units encompassing the requisite glass type.
b) if the clear sizes of the openings of the required glazing are indicated, then the waste quantities can be taken into account in the calculation and the clear sizes used as the basis of the costs charged.

IV) General text for tender (recommendations) for Pilkington Profilit™ pivoted casements, for installation in Pilkington Profilit™ glass walls (standard profiles - series 60)
a) not thermally broken
Item 1) approx. ....... units professional manufacture, supply and, as extra, installation of Pilkington Profilit™ pivoted casement, mill finished, RAL-coated or anodised as per E6/EV1, with concealed catch, cord pull and hook plate. Size ................. x ................. mm (width x height). All-round lip seal. Glazed using: Pilkington Profilit™ glass (NP) or Iso-glazing (standard 24 mm). The venting should be taken into account when sizing up.
€/unit .......................................
Item 2) additional cost of supply and as extra, professional installation of skylight opener, galvanised with gloss finish, complete with 2 adjustment plates in the wing unit located on the side at the bottom, lateral shaft 15/3 mm, bar pull 12 mm up to 2,0 m long, anodised aluminium hand lever, opening width 300 mm, max. width 1600 mm. If, in case of pivoting wing, top-hung sash or pivot –hung window, the hand lever from the bar of the skylight opener needs to be mounted on the side part of the H-frame, then the lateral shaft must be fitted to the left or to the right, and the hand lever needs to be cranked as per existing soffit. The customer should indicate this when placing his order.
€/unit .......................................
Item 3) additional cost of pull bar, galvanised with gloss finish.
€/running metre .......................................
Item 4) additional cost of extra locking device for Item 1) (with grip handle).

b) thermally broken
Item 1) approx. ....... units professional manufacture, supply and, as extra, installation of heat-insulated Pilkington Profilit™ pivoted casement, mill finished, RAL-coated or anodised* as per E6/EV1, with concealed spring loaded catch, cord pull and hook plate. Size ................. x ................. mm (width x height). All-round lip seal. Glazed using: Pilkington Profilit™ glass (NP) or Iso-glazing (standard 24 mm). The venting should be taken into account when sizing up.
€/unit .......................................

V) General text for tender (recommendations) for Pilkington Profilit™ hinged wing units for installing in Pilkington Profilit™ glass walls (Special profiles - Series 83)
a) not thermally broken
Item 1) approx. ....... units professional manufacture, supply and, as extra, installation of Pilkington Profilit™ pivoting casements, mill-finished, RAL coated or anodised as per E6/EV1, with spring loaded catch, cord pull and hook plate. Size ................. x ................. mm (width x height). All round lip seal. Glazed using: Pilkington Profilit™ glass (NP) or Iso-glazing (standard 24 mm). The venting should be taken into account when sizing up.
€/unit .......................................

b) thermally broken
Item 1) approx. ....... units professional manufacture, supply and, as extra, installation of thermally broken Pilkington Profilit™ pivoting casements, mill-finished, RAL-coated or anodised* as per E6 / EV1, with concealed spring-loaded catch, cord pull and hook plate. Size ................. x ................. mm (width x height). All-round lip seal. Glazed using: Pilkington Profilit™ glass (SP) or Iso glazing (standard 24 mm). The venting should be taken into account when sizing up.
€/unit .......................................

Important notes:





  • Other ventilation shutter types can be used.

  • Separate tenders should be prepared for venting reinforcements (e.g. H-frames).



Please use the appropriate Profilit™ terminology in tenders for Pilkington Profilit™.
The recommendations for tendering are available to anyone; the user is responsible for ensuring that they are used correctly in individual cases.
No legal claims of any kind may be derived from the statements made here.

Bauglasindustrie GmbH

Hüttenstraße 33

D-66839 Schmelz/Saar, GERMANY


Phone: +49 (0) 68 87 / 3 03 - 0

Fax: +49 (0) 68 87 / 3 03 - 45


Edition July 2006 (international):

All earlier publications become invalid with this issue. Subject to alteration. Not to be reproduced without permission.






page /