Note: ODEQ recommended these values in an e-mail from E. Milligan to M. Aguilar, 2/2/2005
Inventory – G-P
For the NAAQS impact analysis, the model inventory includes all emission sources from the entire Mill at their potential emission rates. The inventory does not include any offset or negative emission sources. Table D-13 summarizes the emission rates for the NAAQS analyses. The modeled emission rates are identical to the rates in the current Title V permit application (with exceptions noted).
Table D-13 Model ID
|
Source Description
|
Emission Rates (g/s)
|
|
PM10
|
SO2
|
NOX
|
1112_7
|
PM 11 Yankee Dry End Exh. Maximum
|
0.103
|
0.003
|
0.363
|
1112_8
|
PM 11 Yankee Wet End Exh.Maximum
|
0.103
|
0.003
|
0.363
|
1112_20
|
PM12 Yankee Exh -Maximum
|
0.257
|
0.0064
|
0.4990
|
13_13
|
PM13 Yankee Economizer - Maximum
|
0.232
|
0.0047
|
1.0584
|
14_13
|
PM14 Yankee Wet End Exh. - Maximum
|
0.116
|
0.0032
|
0.6615
|
14_17
|
PM17 Yankee Dry End Exh. - Maximum
|
0.116
|
0.0032
|
0.6615
|
15_13
|
PM15 Yankee Wet End Exh. - Maximum
|
0.110
|
0.0032
|
0.378
|
15_18
|
PM15 Yankee Dry End Exh. - Maximum
|
0.110
|
0.003
|
0.378
|
1112_20
|
PM12 Yankee
|
0.243
|
0.0021
|
1.0584
|
1112_1
|
Building Exhaust
|
0.018
|
--
|
--
|
1112_2
|
Building Exhaust
|
0.018
|
--
|
--
|
1112_3
|
Building Exhaust
|
0.018
|
--
|
--
|
1112_4
|
Building Exhaust
|
0.018
|
--
|
--
|
1112_5
|
Building Exhaust
|
0.018
|
--
|
--
|
1112_9
|
Building Exhaust
|
0.018
|
--
|
--
|
1112_10
|
Building Exhaust
|
0.018
|
--
|
--
|
1112_11
|
Building Exhaust
|
0.018
|
--
|
--
|
1112_13
|
Building Exhaust
|
0.018
|
--
|
--
|
1112_14
|
Building Exhaust
|
0.018
|
--
|
--
|
1112_15
|
Building Exhaust
|
0.018
|
--
|
--
|
1112_17
|
After Dryer Exh.
|
0.015
|
--
|
--
|
1112_18
|
After Dryer Exh.
|
0.015
|
--
|
--
|
1112_19
|
After Dryer Exh.
|
0.015
|
--
|
--
|
1112_22
|
Vacuum Pump
|
0.009
|
--
|
--
|
1112_23
|
Vacuum Pump
|
0.009
|
--
|
--
|
1112_24
|
Former Exh
|
0.019
|
--
|
--
|
1112_25
|
Fan Pump Silo
|
0.002
|
--
|
--
|
1112_26
|
Wall Exh.
|
0.009
|
--
|
--
|
1112_28
|
Wall Exh.
|
0.009
|
--
|
--
|
1112_29
|
Fan Pump Silo
|
0.002
|
--
|
--
|
1112_30
|
Former Exh
|
0.018
|
--
|
--
|
1112_31
|
Wall Exh.
|
0.009
|
--
|
--
|
1112_27
|
Wall Exh.
|
0.009
|
--
|
--
|
1112_32
|
Wall Exh.
|
0.009
|
--
|
--
|
13_13
|
Yankee Economizer
|
0.218
|
0.0024
|
1.0584
|
13_1
|
Roof Exhausts
|
0.013
|
--
|
--
|
13_2
|
Roof Exhausts
|
0.013
|
--
|
--
|
13_3
|
Roof Exhausts
|
0.013
|
--
|
--
|
13_4
|
Roof Exhausts
|
0.013
|
--
|
--
|
13_5
|
Roof Exhausts
|
0.013
|
--
|
--
|
13_6
|
Roof Exhausts
|
0.013
|
--
|
--
|
13_7
|
Roof Exhausts
|
0.013
|
--
|
--
|
13_10
|
After Dryer Hood Exh
|
0.025
|
--
|
--
|
13_14
|
Fan Pump Silo
|
0.003
|
--
|
--
|
13_17
|
Vacuum Pump
|
0.011
|
--
|
--
|
13_18
|
Former Exh
|
0.018
|
--
|
--
|
13_19
|
Wall Exh. Fan
|
0.009
|
--
|
--
|
13_20
|
Wall Exh. Fan
|
0.009
|
--
|
--
|
14_13
|
Yankee Wet End
|
0.109
|
0.0014
|
0.5292
|
14_17
|
Yankee Dry End
|
0.109
|
0.0014
|
0.5292
|
14_1
|
Vacuum Pump exh.
|
0.007
|
--
|
--
|
14_2
|
Building exh.
|
0.014
|
--
|
--
|
14_3
|
Building exh.
|
0.014
|
--
|
--
|
14_4
|
Building exh.
|
0.014
|
--
|
--
|
14_5
|
Building exh.
|
0.014
|
--
|
--
|
14_6
|
Building exh.
|
0.014
|
--
|
--
|
14_7
|
Building exh.
|
0.014
|
--
|
--
|
14_8
|
Building exh.
|
0.014
|
--
|
--
|
14_9
|
Building exh.
|
0.014
|
--
|
--
|
14_10
|
Fan Pump Silo Exh.
|
0.012
|
--
|
--
|
14_11
|
Former Exh.
|
0.013
|
--
|
--
|
14_20
|
Wall Exh. Fan
|
0.012
|
--
|
--
|
14_21
|
Wall Exh. Fan
|
0.012
|
--
|
--
|
14_22
|
Wall Exh. Fan
|
0.012
|
--
|
--
|
15_13
|
Yankee Wet End
|
0.103
|
0.0015
|
0.5292
|
15_18
|
Yankee Dry End
|
0.103
|
0.0015
|
0.5292
|
15_11
|
Riffler Roof Exhaust
|
0.009
|
--
|
--
|
15_12
|
Former Exhaust w/ separator
|
0.021
|
--
|
--
|
15_2
|
Roof Exh.
|
0.012
|
--
|
--
|
15_3
|
Roof Exh.
|
0.012
|
--
|
--
|
15_4
|
Roof Exh.
|
0.012
|
--
|
--
|
15_5
|
Roof Exh.
|
0.012
|
--
|
--
|
15_6
|
Roof Exh.
|
0.012
|
--
|
--
|
15_7
|
Roof Exh.
|
0.012
|
--
|
--
|
15_8
|
Roof Exh.
|
0.012
|
--
|
--
|
15_9
|
Roof Exh.
|
0.012
|
--
|
--
|
15_22
|
Roof Exh.
|
0.012
|
--
|
--
|
15_1
|
Vacuum Pump Silo
|
0.014
|
--
|
--
|
15_19
|
Wall Fan
|
0.010
|
--
|
--
|
15_20
|
Wall Fan
|
0.010
|
--
|
--
|
15_21
|
Fan Pump Silo
|
0.006
|
--
|
--
|
PPRTO
|
Proposed RTO
|
0
|
0
|
0.063
|
Stack1
|
Boilers 1 and 2 (a)
|
9.45
|
74.34
|
46.62
|
Stack3
|
Boilers 3 and 4 (a)
|
14.04
|
168.44
|
98.25
|
RCUN
|
Railcar Unload
|
0.00521
|
--
|
--
|
STKER
|
Coal Stacker
|
0.00521
|
--
|
--
|
GRIZZLY
|
Coal Grizzly
|
0.00521
|
--
|
--
|
CRUSHER
|
Coal Crusher
|
0.0675
|
--
|
--
|
BNKXF
|
Bunker Coal Transfer
|
0.450
|
--
|
--
|
RDA1..A39
|
Main Gate to 1st intersection
|
0.00866
|
--
|
--
|
RDB1..B57
|
1st Intersection to Coal Pile
|
0.00059
|
--
|
--
|
RDC1..C28
|
1st Intersection to Shipping/Rcv
|
0.00635
|
--
|
--
|
RDD1..D300
|
Ash Management
|
0.01459
|
--
|
--
|
Additional Source For NAAQS Analysis
|
RESIN
|
Resin Material Baghouse
|
0.025
|
--
|
--
|
Total for NAAQS Analysis
|
26.2
|
191.61a
|
150.23
|
(a) Muskogee Mill proposes to restrict total SO2 emissions from Boilers 1 through 4 combined to 191.6 grams/second.
Table D-14 summarizes the modeling parameters for the RESIN source, which was not affected by the project and thus not included in the significant impact analysis.
Table D-14
Parameter
|
Value
|
Easting (m)
|
291920
|
Northing (m)
|
3956855
|
Stack Ht (m)
|
20.74
|
Exit Temp K
|
Ambient
|
Exit Velocity (m/s)
|
17.7
|
Exit Diameter (m)
|
0.298
|
Share with your friends: |