2. APU Generator
|
B
|
1
|
0
|
(M) Except for ER operations, may be inoperative provided APU is not used.
|
Maintenance will pull and collar APU CONT #1 – left EER C-13 and APU CONT #2 – right EER C-11.
Flight crew may accomplish this task if properly qualified and authorised.
|
None required.
|
An Inoperative Placard will be placed above AUX PWR Switch on EPCP and will be noted on ADLS.
|
3. Transformer-Rectifier
Units (TRUs)
|
B
|
5
|
4
|
(M) May be inoperative provided:
a) Both Generators are operative,
b) Both essential TRUs are operative,
c) Auxiliary TRU is operative,
d) APU Generator is operative,
e) Both Battery chargers are operative,
f) Both Main Aeroplane Batteries are operative, and
g) Inoperative TRU circuit breaker on the Power Distribution Box is pulled and collared.
|
Maintenance will pull and collar affected TRU CONTROL CB on Power Distribution Box (PDB). Maintenance will ensure AUX TRU is operative and both essential TRUs are operative.
Flight crew may accomplish this task if properly qualified and authorised.
|
None required.
|
An Inoperative Placard will be placed in a prominent position to be seen by flight crew and will be noted on ADLS.
|
4. Main Aeroplane
Battery Chargers
|
B
|
2
|
1
|
(M) May be inoperative provided:
a) Both Engine Generators are operative,
b) APU Generator is operative,
c) Associated Battery Charger circuit breaker on the Power Distribution Box is pulled and collared, and
d) Standby Electrical System is operative.
|
Maintenance will pull and collar CB of associated Battery Charger (located on PDB). Maintenance can verify associated Battery Charger by utilizing Operational Test located in AMM Chapter 24-34-03.
Flight crew may accomplish this task if properly qualified and authorised.
|
None required.
|
An Inoperative Placard will be placed above Battery Charger Circuit Breakers and will be noted on ADLS.
|