Normal Bus Operation Controls


Engine start switch

Transmission selector

Door control

Turn signal

Dash heater / defroster

Windshield wiper

Master run switch

Parking brake

High beam

Hazard lights

Kneeling ramp control (optional)

Instrument lighting control



    1. Special Controls


ABS diagnostic test

Stop engine override

Drivers fan (optional)

Exterior mirror heater/remote controls (optional)

Dash air conditioning (optional)

Fire suppression (optional)

Engine diagnostic test connectors

Stop request chime (optional)

Fast Idle

P.A. (optional)

Diagnostic light panel test

Destination Sign control (optional)




    1. Passenger Comfort Controls


Climate control (temperature select)

Interior HVAC (blower)

Interior lights (passenger compartment)

    1. Operator Foot Controls


Accelerator pedal

Brake pedal

Turn signals

High beam



    1. The Driver’s Instrument:


Tachometer

Speedometer

Fuel gauge

Oil pressure gauge

Coolant temperature gauge

Voltmeter

Dual air gauge

    1. Dash Mounted Telltale Lights:


Low oil pressure

Coolant temperature

Lift deployed

Alternator fail

Engine shutdown

Park brake

High beam

Air conditioning inoperative



Low air pressure

  1. WINDSHIELD WIPERS AND WASHERS


Two speed electric wipers shall be provided, one (1) on each side with a single control.


  1. ARMS AND BLADES - Wiper arms shall be pantograph type 27.5” long and blades are 23.5” long. The wiper blades shall park at center of windshield.




  1. WASHER - Electric pump, 3-gallon washer reservoir, supplying nozzles located on wipers wet arm.




  1. INTERMITTENT WIPERS - Variable speed control allowing timed intermittent windshield cleaning.



  1. USSC - 9100ALX DRIVER’S SEAT


A USSC, model 9100 ALX air suspension driver’s seat shall be provided. The seat shall feature six-way adjustments with air actuated lower lumber support. The driver seat shalll be covered in black transit cloth.

  1. PASSENGER SEATING


The bus shall accommodate 36 seated passengers, with the flexibility to accommodate two ADA compliant wheelchair positions. A total of six aisle facing passenger seats may be flipped up when both wheelchair tie downs are in use. Freedman Seating - CitiSeats with padded Level 5 cloth inserts shall be provided. The seating plan/floor plan shall incorporate perimeter seating on the forward half of the bus, and forward facing seating on the rear half of the bus . All forward facing double seats are to incorporate seat back mounted grab handles. The bus shall also accommodate 36 standee passengers for a total passenger capacity of 72, plus the driver. A weight calculation confirming that the front and rear GAWR as well as overall GVWR are not exceeded with the aforementioned passenger load is required with the Supplier’s proposal.

  1. EXTERIOR MIRRORS


Fully adjustable 15" x 8" overall, two (2) part mirrors shall be supplied. The upper section shall utilize a 8-1/2” section of flat glass. The lower section shall be 5-1/2” convex adjustable diminishing glass. The mirrors shall be installed with quick mount disconnects, and shall be supported by rigid adjustable black powder coated arms. The aforementioned exterior mirrors shall include heated and remote controlled features.

  1. INTERIOR MIRROR


Driver's passenger viewing 8" x 15" convex fully adjustable rearview mirror shall be mounted in easy reach.

  1. CENTER DOOR VIEWING CONVEX MIRRORS


A 12" diameter convex mirror shall be installed behind and above the doorway. This mirror shall be viewed through a 6” diameter convex mirror mounted in the upper front interior corner of the bus.

  1. WINDOWS


All windows shall meet State and Federal Safety Regulations. Windshield shall be AS 1. Driver's side windows shall be AS 2, and passenger windows shall be AS 3 in quality.


  1. WINDSHIELD - The windshield shall utilize a BRT style, swept-back design with two (2) piece, 1/4" thick, 73% single density laminated safety float glass. The windshield shall have a dark tinted sun-shade across top for driver safety. The windshield shall be glazed with two (2) piece black ozone treated extruded locks and key rubber.




  1. DRIVER'S WINDOW - The driver’s window shall incorporate black “PPG’s - Macroflex Coating, extruded aluminum sash with a single slider design in the lower ¾ of the window. The window shall be glazed with 1/8" nominal thickness tempered safety sheet glass.




  1. DOOR WINDOWS - Door windows shall be glazed with 1/8" nominal thickness tempered safety sheet glass. Each window shall be installed in the upper and lower portions of the passenger door(s).




  1. PASSENGER SIDE WINDOWS - The passenger windows shall feature black painted “PPG’s - Macroflex Coating, extruded aluminum sash frames with upper T slide transom openings. The windows shall be glazed with 1/8" nominal thickness, tempered safety sheet glass. An adequate number of windows shall be provided on each side designed to meet FMVSS 217 for emergency egress.




  1. SIDE DESTINATION SIGN WINDOW   The first curbside passenger window behind the front door shall be glazed with 1/8" nominal thick clear tempered safety glass in the upper transom section for sign viewing




  1. PASSENGER COMPARTMENT HVAC SYSTEMS

Passenger compartment heating and air conditioning systems shall be as specified hereafter:

  1. Directory: PRSapp -> bid-documents -> EQ Folder
    EQ Folder -> 6 Full Power Racks with Pull Up Bar (Maximum 8 feet tall)
    bid-documents -> Request for Qualifications
    bid-documents -> Invitation to bid your firm is hereby invited to submit to the City of Atlanta, Department of Procurement “dop
    bid-documents -> Invitation to bid your firm is hereby invited to submit to the City of Atlanta, Department of Procurement “dop
    bid-documents -> Wednesday, September 10, 2014 addendum number 1 Solicitation Number: itb 900 15-625 Title: Parking Areas & Decks Cleaning & Sweeping
    bid-documents -> Invitation to bid your firm is hereby invited to submit to the City of Atlanta, Department of Procurement “dop
    bid-documents -> Atlanta Falcons Stadium Company, llc (“Falcons”) Georgia World Congress Center Authority (“Authority”)
    EQ Folder -> Attachment "E"
    EQ Folder -> Georgia department of corrections

    Download 0.55 Mb.

    Share with your friends:
1   ...   6   7   8   9   10   11   12   13   ...   16




The database is protected by copyright ©ininet.org 2024
send message

    Main page