Inventory – Competing Sources

A full analysis must include the emissions of competing sources. G-P considered competing sources within the screening area. The screening area is unique for each pollutant, and is the area within a circle centered on the project with a radius equal to the significant impact distance plus 50 km, but not to exceed 100 km. The screening areas for NO2, PM10, and SO2, are 55, 52.5 and 58 km, respectively. Table D-15 presents a summary of competing sources within 60 km of the Mill provided by ODEQ.


Table D-15

Facility ID

Facility

Site City

Distance

From Mill

(km)

Direction

From Mill

(degrees)

Potential Emissions (lb/hr)

SO2

NO2

PM10

13665

American Foundry Group

Muskogee

1.0

278

0.02

3.26

3.95

9943

OG&E

Fort Gibson

3.3

357

19808

11844

463

9987

Owens Brockway Glass Cntr

Muskogee

5.5

322

29.6

160.7

20.4

10113

Sintertec Div Of BPI Inc

Muskogee

5.8

352

9.5

15.8

5.9

8668

Boral Bricks Of Texas LP

Muskogee

11.6

244

18.8

29.9

24.4

10242

Global Stone St Clair Inc

Marble City

44.4

111

256.8

149.8

36.4

18787

Calpine Corp

Coweta

47.9

312

11.72

361

55.68

9257

Grand River Dam Auth

Chouteau

51.2

2

9334

6239.7

660.6

G-P included all competing sources within 60 km in the NAAQS modeling analysis. Table D-16 presents the individual stack parameters for sources at these facilities. In cases of missing stack parameters in the data, the following assumptions were made.

For point sources, stack temperature set to ambient (293 K), stack diameter set to 0.001 m, exit velocity set to 0.001 m/s, and stack height set to 10 feet.

For fugitive sources, release height set to 10 meters, vertical extent set to 10 m, initial vertical dispersion coefficient (z) of m, lateral extent set to 5 m, and initial lateral dispersion coefficient (y) set to 1.16 m or based on footprint of source area.




Table D-16 (page 1)

Facility / Source Description

Model ID

Potential Emissions (gram/sec)

Stack Ht

(m)

Stack Diam

(m)

Stack Temp

K

Exit Velocity

m/s

Volume Source Dimensions (m)

SO2

NO2

PM10

Sig y

Sig z

 































AMERICAN FOUNDRY GROUP































Electric Induction Furnaces

13665

0

0

(a)

3.0

NA

NA

NA

1.16

2.33

Pouring and Casting

13666

0

0

(a)

3.0

NA

NA

NA

1.16

2.33

Casting Cleaning

13667

0

0

(a)

3.0

NA

NA

NA

1.16

2.33

Charge Handling

13668

0

0

(a)

3.0

NA

NA

NA

1.16

2.33

Casting Cooling

13669

0

0

(a)

3.0

NA

NA

NA

1.16

2.33

Sand Grinding

13670

0

0

(a)

3.0

NA

NA

NA

1.16

2.33

Ladle Heaters

13673

0.0025

0.411

0.498

10

NA

NA

NA

11.62

9.31


































OG&E (per permit)































Unit #3

9943

10.04

71.49

5.52

53.6

4.7

422

9.3







Unit #4

9944

828.58

483.34

13.04

106.7

7.3

402

14.1







Unit #5

9945

828.58

483.34

13.04

106.7

7.3

402

14.1







Unit #6

9946

828.58

454.23

26.71

152.4

6.6

402

25.2







Coal Crushing, Loading, and Handling

9947

0

0

0.068

10.0

NA

NA

NA

5

8.3


































OWENS BROCKWAY GLASS































Glass Melting Furnace #4

9987

0.9702

7.65

0.781

45.7

1.6

765

8.9







Glass Melting Furnace #42

9988

2.76

12.60

1.79

24.4

2.1

471

9.0








































SINTERTEC DIV OF BPI INC































Kiln #1 (Shuttle)

10113

1.197

1.99

0.315

10.1

0.4

505

19.1







Raw Mill

10117

0

0

0.214

10.1

0.4

294

19.1







Crushing (Primary,Secondary,Tertiary)

10118

0

0

0.214

10.1

0.4

294

19.1










Table D-16 (Page 2)

Facility / Source Description

Model ID

Potential Emissions (g/sec)

Stack Ht

(m)

Stack Diam

(m)

Stack Temp

K

Exit Velocity

m/s

Volume Source Dimensions (m)

SO2

NO2

PM10

Sig y

Sig z


































BORAL BRICKS OF TEXAS LP































Tunnel Kiln

8668

2.37

3.77

3.07

8.5

1.5

533

12.4








































GLOBAL STONE ST CLAIR INC































Rotary Lime Kiln #1 - KVS

10242

11.94

6.97

1.76

29.3

2.1

341

9.5







Rotary Lime Kiln #2 - Fuller

10243

20.41

11.91

2.82

30.5

2.1

341

14.4








































CALPINE CORP































Power Block 1, #1-1

18787

0.738

22.74

3.51

43.9

6.1

355

14.4







Power Block 2, #2-1

18789

0.738

22.74

3.51

43.9

6.1

355

14.4








































GRAND RIVER DAM AUTH































Electric Power Generation Unit #1

9257

775.78

452.55

64.65

153.9

6.1

408

27.6







Electric Power Generation Unit #2

9258

400.30

333.65

18.59

153.9

6.1

344

26.4








































(a) PM10 Emissions for all American Foundry Group sources modeled as a single source - 13673

Table D-17 presents UTM locations and estimated base elevation from an AERMAP analysis.



Download 2.8 Mb.