Request for Proposal [insert date]



Download 1.62 Mb.
Page23/61
Date17.10.2016
Size1.62 Mb.
#310
TypeRequest
1   ...   19   20   21   22   23   24   25   26   ...   61

Raceway


A raceway shall be provided through the turntable area to accommodate to maximum deflection of the turntable. The raceway shall prevent chafing, binding, rubbing, crimping or leakage of all hydraulic, air, fuel and system support lines, as well as all electrical and electronic cabling through or to the turntable area. Lines shall be secured, separated and labeled at the lead and trailing unit bulkheads. Separation shall be maintained on the flexible portion of all lines through the use of a raceway. All electrical terminations and hose fittings shall be easily visible and easily tightened or removed without removing any other component. Lines, routing, securement and labeling shall be approved by the Agency.

Bulkhead fitting shall be provided for all lines: air coolant, electrical and AC at both ends of the raceway. The bulkhead area shall be easily accessible for servicing.


Bellows


Replacement fabric type bellows with draft-free, no-sag bottom closure and water drains shall be provided between the lead and trailing sections to seal the bus interior and keep it free of water, dirt and drafts. Bellows hardware shall be corrosion resistant, and the under-floor area of the bellows shall be easy to clean when necessary. The passageway between the lead unit and trailing unit shall have an inside cross section that is as nearly equal as possible to the inside cross section of the bus bodies, with no tripping or pinching hazards created by the turntable cross section or closeouts. The bellows shall be durable, and its supporting structure and stiffeners shall support the bellows material in a neat, sag-free manner. The Contractor shall supply information on the actual service life achieved by the type of bellows being proposed. A sample of the bellows and attaching hardware may be requested for evaluation at the Agency’s option. Bellows shall be approved by the Agency.

Alternative

Bellows liner.

CHASSIS

Suspension

General Requirements


The front, rear and mid (if articulated) suspensions shall be pneumatic type. The basic suspension system shall last the service life of the bus without major overhaul or replacement. Adjustment points shall be minimized and shall not be subject to a loss of adjustment in service. Routine adjustments shall be easily accomplished by limiting the removal or disconnecting the components.

Alignment


All axles should be properly aligned so the vehicle tracks accurately within the size and geometry of the vehicle.

Springs and Shock Absorbers

TS 1.1.6Suspension Travel


The suspension system shall permit a minimum wheel travel of 2.75 in. jounce-upward travel of a wheel when the bus hits a bump (higher than street surface), and 2.75 in. rebound-downward travel when the bus comes off a bump and the wheels fall relative to the body. Elastomeric bumpers shall be provided at the limit of jounce travel. Rebound travel may be limited by elastomeric bumpers or hydraulically within the shock absorbers. Suspensions shall incorporate appropriate devices for automatic height control so that regardless of load the bus height relative to the centerline of the wheels does not change more than ½ in. at any point from the height required. The safe operation of a bus cannot be impacted by ride height up to 1 in. from design normal ride height.

TS 1.1.7Damping


Vertical damping of the suspension system shall be accomplished by hydraulic shock absorbers mounted to the suspension arms or axles and attached to an appropriate location on the chassis. Damping shall be sufficient to control coach motion to three cycles or less after hitting road perturbations. The shock absorber bushing shall be made of elastomeric material that will last the life of the shock absorber. The damper shall incorporate a secondary hydraulic rebound stop.

TS 1.1.8Lubrication


Default

Standard Grease Fittings

All elements of steering, suspension and drive systems requiring scheduled lubrication shall be provided with grease fittings conforming to SAE Standard J534. These fittings shall be located for ease of inspection and shall be accessible with a standard grease gun from a pit or with the bus on a hoist. Each element requiring lubrication shall have its own grease fitting with a relief path. The lubricant specified shall be standard for all elements on the bus serviced by standard fittings and shall be required no less than every 6000 miles.
Alternative

Auto lube.


Alternative

Remote grease manifold.


TS 1.1.9Kneeling


Default

A kneeling system shall lower the entrance(s) of the bus a minimum of 2.5 in. during loading or unloading operations regardless of load up to GVWR, measured at the longitudinal centerline of the entrance door(s) by the driver. The kneeling control shall provide the following functions:

• Downward control must be held to allow downward kneeling movement.

• Release of the control during downward movement must completely stop the lowering motion and hold the height of the bus at that position.

• Upward control actuation must allow the bus to return to normal floor height without the driver having to hold the control.

The brake and throttle interlock shall prevent movement when the bus is kneeled. The kneeling control shall be disabled when the bus is in motion. The bus shall kneel at a maximum rate of 1.25 in. per second at essentially a constant rate. After kneeling, the bus shall rise within 3 seconds to a height permitting the bus to resume service and shall rise to the correct operating height within 7 seconds regardless of load up to GVWR. During the lowering and raising operation, the maximum vertical acceleration shall not exceed 0.2g, and the jerk shall not exceed 0.3g/second.

An indicator visible to the driver shall be illuminated until the bus is raised to a height adequate for safe street travel. An audible warning alarm will sound simultaneously with the operation of the kneeler to alert passengers and bystanders. A warning light mounted near the curbside of the front door, a minimum 2.5 in. diameter amber lens, shall be provided that will blink when the kneel feature is activated. Kneeling shall not be operational while the wheelchair ramp is deployed or in operation.
Alternative

Allow upward kneel actuation with ramp deployed.


ALTERNATIVE

Full right-side kneel capabilities.




Download 1.62 Mb.