Design and Function

In the standard version, 5 or 10 charge-discharge circuits are combined in one cabinet with a common power supply. Each circuit is provided with its own control unit and the respective power unit. Three-phase AC ensures the mains supply. GUBT25/50A12V can resolve the main power failure problem and continue with testing automatically after that.

The programmable control unit is the core of each charge-discharge circuit. It is a standalone microcomputer system for a data logging and precise control of analogue measured values. It also assumes the processing of stored test programs.

In the manual operating mode, it is possible to select one of the stored programs No 1-8, interrupt and terminate the program by pressing the respective button. Digital instruments for battery voltage and current are fitted on the front panel.

Automatic operating mode is made via host computer with GBTS106 party line host computer software.
Testing:


  1. C-20 twenty hours capacity

  2. Rc spare capacity (reserve)

  3. Cycling

  4. Life time period testing

  5. Charge acceptance

  6. Charge retention

  7. Water consumption.

Examples: Figure 2, figure 3, figure 4, figure 5.



Figure2. Testing on capacity C-20



Figure 3. Spare capacity Rc



Figure 4. Life time testing in cycles




Figure 5. Charge acceptance
Etc…

The Programs

All tests programs can be split into steps, where certain operations must be executed under well-defined conditions. Each step is fixed in a program line.

Each program step is divided into columns and each column has a headline describing its function.

Column explanations:

Column: Label

Each program step can be labeled which is used for controlling of program executing.



Column: Operation

Each program step starts with an operator determining the function of the test circuit. The operator names are simple abbreviations of the respective functions (charge, discharge, ramp, cycle, pause, stop).



Column: Set value

As nominal values for this step may be entered current, voltage or resistance of power values.



Column: Term. condition

The termination values current, voltage, time, capacity, energy and temperature determine the end of a program step and thus the beginning of the next program step. In building of condition can be used logical operators AND, OR, NOT.



Column: Term. action

Possibilities for The Term. Action columns are:

  • GOTO label -transfers program control to the specified program step

  • NEXT -goes to the next program step

  • STOP -terminates program

Column: Abort condition

The values entered under this column may be the same as for the termination values. However, in this case, the program run will be terminated if one of these limit values is reached.

Column: Registration

The conditions for the registration are entered into the last column. These may be time intervals or changes in current, voltage, capacity, energy or temperature.




Technical Data

GUBT25/50A12V (5 units 25A/12V and 5 units 50A/12V)



Charge/discharge current:

25A/50A

Nominal battery voltage:

12V

Charge voltage range:

10V-18V

Discharge voltage range:

5V-16V

Accuracy:

0,5% of set value

Power circuits:

Transistors

Controlled characteristics:

constant current, voltage, power, resistance

Control elements:

main switch, program selector switch, party line connection, start and stop buttons

Displays:

LED’s for power, active, charge, discharge, digital instruments for current and voltage with additional test sockets

Controlled variables:

current, voltage, power and resistance

Termination values:

charge time, charge voltage, charge current, Ah charged, Wh charged, discharge time, final discharge voltage, discharge current, Ah discharged, Wh discharged

Programmable functions:

charge, discharge, pause, cycles, cycles in cycles, “go to” steps

Display of measuring values:

during operation permanently on the monitor of the host computer

Displayed and printed measuring values for each program step:

voltage, current, time

Power requirements: 3x380V/50Hz

Ambient temperature: 10 to 40C.


Price:

  1. Gaus Universal Battery Tester GUBT25/50A12V (5x25A/12V+5x50A/12V) 29850 US$

Delivery Time: three months

Warranty Period: 1 (one) year



Download 2.86 Mb.