The Target Store T-1849 at the Intersection of Flatbush Ave. and Atlantic Blvd., Atlantic Terminal in Brooklyn, NY. was inspected by Thomas Branham of Elevator Consulting Services, Inc. on May 6, 2015 to assess the equipment reliability and status. My QEI number is 1339 and am certified by NAESA. NAESA is the National Association of Elevator Safety Authorities. We have identified corrective items that in our opinion need to be addressed by the Elevator Contractor. They are free to offer an explanation or dispute any individual item within the report but we can offer a reasonable reason for each and every negative evaluation. They are evaluated on and for the ASME 17.2 Code for Inspectors Manual and industry standards for acceptable installation and maintenance procedures.
Store #: 718-290-1109 - TSC desk, Need when you go on the roof and you want to get back in, call this number for an LOD to reopen door..
Service Vendor: TEI
PMT – Michael 314-940-9530
Note: ILO – Inside Looking Out
OLI - Outside Looking In
Items in red suggest a higher degree of urgency to get resolved. May be a reliability, callback or safety issue that should be resolved quickly. .
T-1849 ATLANTIC TERMINAL FREIGHT ELEVATORS 7, 8, 9 CORRECTIVE ITEMS The following minimum items need corrective action taken. Documentation of completion is required.
CITY ID 7 – 3F6062 5 YR TEST 7 – 6-12ANL Test 7 – 7-14
8 – 3F6063 8 – 6-12 8 –7-14
9 – 3F6064 9 – 6-12 9 – 7-14 Note: Cars 7 & 8 were shut down so some items in report could not be checked. They were left on based on balance of duplicate items. Elevator 7
Adjust leveling at G level, stops short ½”. REPEAT REQUEST
Date Completed ______________ Initialed __________
Adjust leveling in down direction, short of floors ¾”. REPEAT REQUEST
Date Completed _____________ Initialed ________
Secure all hoistway door tracks, several bolts are missing nuts. REPEAT REQUEST
Date Completed ___________________ Initialed __________
Flush all gate chains, front and rear, with WD-40 and wipe off excess. REPEAT REQUEST
Date Completed ___________________ Initialed __________
Provide a beam pad for the 2nd floor divider beam and tape the traveling cable, worn traveling cable jacket. REPEAT REQUEST
Date Completed ___________________ Initialed __________
Repair the position indicator in the fire command station to proper working order. REPEAT REQUEST
Date Completed ___________________ Initialed __________
Date Completed ___________________ Initialed __________
Elevator 8
The new hoist cables are dropping excessive metal filings on the machine bed and machine room floor. Vacuum up filings, replace ropes. May be wrong hoist ropes for the sheaves. Double check lang lay requirements. REPEAT REQUEST
Date Completed ___________________ Initialed __________
Secure the hoistway access boxes on 2nd floor. REPEAT REQUEST
Date Completed _____________ Initialed ________
Adjust leveling, floor level at 4th floor. ¾” short of floor. REPEAT REQUEST
Date Completed _____________ Initialed ________
The conduit to the 2nd floor zone switch has pulled out of the fitting. Reinsert and tighten set screw. REPEAT REQUEST
Date Completed ___________________ Initialed __________
Clean the car top. REPEAT REQUEST
Date Completed ___________________ Initialed __________
Flush all gate chains, front and rear, with WD-40 and wipe off excess. REPEAT REQUEST
Date Completed ___________________ Initialed __________
Secure the Car Operating Panel, only 1 screw out of 8 is holding the panel. REPEAT REQUEST
Date Completed ___________________ Initialed __________
Lower the weight containment clip on the counterweight. REPEAT REQUEST
Date Completed ___________________ Initialed __________
The bottom hoistway door track support has pulled away from the wall. Properly secure. REPEAT REQUEST
Date Completed ___________________ Initialed __________
Tape the hoistway door astragal on 2nd floor. 10” slice on right side (OLI). REPEAT REQUEST
Date Completed ___________________ Initialed __________
The car operating panel is held in by one screw, 7 are missing. Secure to faceplate properly. REPEAT REQUEST
Date Completed ___________________ Initialed __________
Remove service panel door or fix it. REPEAT REQUEST
Date Completed ___________________ Initialed __________
Door close button on 2nd floor does not work. REPEAT REQUEST
Date Completed ______________ Initialed __________
Replace the damaged hall access box on ‘G’ level, left side. (OLI). REPEAT REQUEST
Date Completed ______________ Initialed __________
Clean all the entrance tracks of all dirt and dust. Includes all lock hardware, junction box covers, retiring cam and related equipment. Pistons have been cleaned, looking for a more comprehensive cleaning. REPEAT REQUEST
Date Completed ___________________ Initialed __________
Elevator 9
Door close button on 2nd floor does not work. REPEAT REQUEST
Date Completed ______________ Initialed __________
Secure the hoistway access boxes on 2nd floor. REPEAT REQUEST
Date Completed ______________ Initialed __________
Adjust leveling in down direction, short of floors. REPEAT REQUEST
Date Completed _____________ Initialed ________
Repair the Position Indicator in the car. REPEAT REQUEST
Date Completed ___________________ Initialed __________
Repair the position indicator in the hall. REPEAT REQUEST
Date Completed ___________________ Initialed __________
Clean the car top. REPEAT REQUEST
Date Completed ___________________ Initialed __________
Flush all gate chains, front and rear, with WD-40 and wipe off excess. REPEAT REQUEST
Date Completed ___________________ Initialed __________
Flush all hoistway door chains, front and rear, with WD-40 and wipe off excess. REPEAT REQUEST
Date Completed ___________________ Initialed __________
Replace the missing door lock cover at 3rd floor. REPEAT REQUEST
Date Completed ___________________ Initialed __________
Replace the missing door lock cover at G level. REPEAT REQUEST
Date Completed ___________________ Initialed __________
The Phase I key switch is pushed into the hall fixture faceplate. Secure it properly. REPEAT REQUEST
Date Completed ___________________ Initialed __________
Repair the emergency light to proper working order. REPEAT REQUEST
Date Completed ___________________ Initialed __________
Repair the position indicator in the fire command station to proper working order. REPEAT REQUEST
Date Completed ___________________ Initialed __________
Replace the 4th floor hall button light. REPEAT REQUEST
Date Completed ___________________ Initialed __________
Clean all the entrance tracks of all dirt and dust. Includes all lock hardware, junction box covers, retiring cam and related equipment. Pistons have been cleaned, looking for a more comprehensive cleaning. REPEAT REQUEST
Date Completed ___________________ Initialed __________