Page | 17/60 | Date | 02.02.2017 | Size | 6.47 Mb. | | #15690 |
|
U.S. DEPARTMENT OF TRANSPORTATION
MASTER MINIMUM EQUIPMENT LIST
FEDERAL AVIATION ADMINISTRATION
|
AIRCRAFT:
GULFSTREAM G-V, GV-SP,
GV-SP (G550), GV-SP (G500),
GIV-X, GIV-X (G450),
GIV-X (G350)
|
REVISION NO: 7
DATE: 02/04/2010
|
PAGE NO:
24-3
|
1. SYSTEM,
SEQUENCE NUMBERS & ITEM
|
REPAIR CATEGORY
|
|
2. NUMBER INSTALLED
|
|
3. NUMBER REQUIRED FOR DISPATCH
|
|
4. REMARKS OR EXCEPTIONS
|
24
|
ELECTRICAL POWER
|
|
|
|
|
|
|
|
|
|
|
|
|
5.
|
Main Airplane Batteries
|
B
|
2
|
1
|
(M) May be inoperative provided:
-
There are no other electrical power source failures,
-
Associated Battery cables are disconnected and secured,
-
Associated Battery Charger circuit breaker on the Power Distribution Box is pulled and collared, and
-
Associated battery circuit breaker is pulled and collared.
|
|
|
|
|
|
|
|
|
|
|
B
|
2
|
1
|
(M)(O) May be inoperative provided:
-
Airplane is operated in day VMC,
-
Standby Electrical System is operative,
-
Associated Battery cables are disconnected and secured,
-
Associated Battery Charger circuit breaker on the Power Distribution Box is pulled and collared, and
-
Associated battery circuit breaker is pulled and collared.
|
|
|
|
|
|
|
|
|
U.S. DEPARTMENT OF TRANSPORTATION
MASTER MINIMUM EQUIPMENT LIST
FEDERAL AVIATION ADMINISTRATION
|
AIRCRAFT:
GULFSTREAM G-V, GV-SP,
GV-SP (G550), GV-SP (G500),
GIV-X, GIV-X (G450),
GIV-X (G350)
|
REVISION NO: 8
DATE: 11/07/2014
|
PAGE NO:
24-4
|
1. SYSTEM,
SEQUENCE NUMBERS & ITEM
|
REPAIR CATEGORY
|
|
2. NUMBER INSTALLED
|
|
3. NUMBER REQUIRED FOR DISPATCH
|
|
4. REMARKS OR EXCEPTIONS
|
24
|
ELECTRICAL POWER
|
|
|
|
|
|
|
|
|
|
|
|
|
6.
|
Battery Ammeters (Overhead Panel)
|
C
|
2
|
0
|
May be inoperative provided:
-
Associated voltmeter is operative, and
-
Both battery charger fail messages are operative.
|
|
|
|
|
|
|
|
|
|
|
C
|
2
|
0
|
May be inoperative provided battery ammeter indications are available in EICAS.
|
|
|
|
|
|
|
|
|
|
(EICAS Indication)
|
C
|
2
|
0
|
May be inoperative provided the battery ammeters in overhead panel are operative.
|
|
|
|
|
|
|
|
|
|
|
|
7.
|
Battery Voltmeters
(Overhead Panel)
|
C
|
2
|
0
|
May be inoperative provided associated ammeter is operative.
|
|
|
|
|
|
|
|
|
|
|
|
|
C
|
2
|
0
|
May be inoperative provided Battery Voltmeter indications are available on EICAS.
|
|
|
|
|
|
|
|
|
|
|
|
|
(EICAS Indication)
|
C
|
2
|
0
|
May be inoperative provided Battery Ammeters indications are available on EICAS.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
C
|
2
|
0
|
May be inoperative provided Battery Voltmeters in overhead panel are operative.
|
|
|
|
|
|
|
|
|
|
|
|
U.S. DEPARTMENT OF TRANSPORTATION
MASTER MINIMUM EQUIPMENT LIST
FEDERAL AVIATION ADMINISTRATION
|
AIRCRAFT:
GULFSTREAM G-V, GV-SP,
GV-SP (G550), GV-SP (G500),
GIV-X, GIV-X (G450),
GIV-X (G350)
|
REVISION NO: 8
DATE: 11/07/2014
|
PAGE NO:
24-5
|
1. SYSTEM,
SEQUENCE NUMBERS & ITEM
|
REPAIR CATEGORY
|
|
2. NUMBER INSTALLED
|
|
3. NUMBER REQUIRED FOR DISPATCH
|
|
4. REMARKS OR EXCEPTIONS
|
24
|
ELECTRICAL POWER
|
|
|
|
|
|
|
|
|
|
|
|
|
8.
|
Electrical Power System EICAS Displays
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1)
|
L Gen Voltmeter
|
C
|
1
|
0
|
May be inoperative if the frequency and loadmeter are operative.
|
|
|
|
|
|
|
|
|
|
|
2)
|
L Gen Frequency Meter
|
C
|
1
|
0
|
May be inoperative if the voltmeter and loadmeter are operative.
|
|
|
|
|
|
|
|
|
|
|
3)
|
L Gen Loadmeter
|
C
|
1
|
0
|
May be inoperative if the voltmeter and frequency meter are operative.
|
|
|
|
|
|
|
|
|
|
|
4)
|
R Gen Voltmeter
|
C
|
1
|
0
|
May be inoperative if the frequency and loadmeter are operative.
|
|
|
|
|
|
|
|
|
|
|
5)
|
R Gen Frequency Meter
|
C
|
1
|
0
|
May be inoperative if the voltmeter and loadmeter are operative.
|
|
|
|
|
|
|
|
|
|
|
6)
|
R Gen Loadmeter
|
C
|
1
|
0
|
May be inoperative if the voltmeter and frequency meter are operative.
|
|
|
|
|
|
|
|
|
|
|
7)
|
APU Voltmeter
|
C
|
1
|
0
|
May be inoperative if the frequency meter and loadmeter are operative.
|
|
|
|
|
|
|
|
|
|
|
8)
|
APU Frequency Meter
|
C
|
1
|
0
|
May be inoperative if the voltmeter and loadmeter are operative.
|
|
|
|
|
|
|
|
|
|
|
9)
|
APU Loadmeter
|
C
|
1
|
0
|
May be inoperative if the voltmeter and frequency meter are operative.
|
|
|
|
|
|
|
|
|
|
|
10)
|
Ext AC Pwr Voltmeter
|
D
|
1
|
0
|
May be inoperative provided:
a) the frequency meter and
loadmeter are operative, and
b) External AC power is not used.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
(continued)
|
|
|
|
|
|
|
|
|