Logic Outputs

9 PIN Cable End



RS-232 Control
The FS-03 has an RS-232 Serial Port which allows it to be controlled by a third party control system. The FS-03 Serial Port transmits serial data on pin 3 (TxD), receives serial data on pin 2 (RxD), and provides a ground on Pin 5. The Data Terminal Ready (DTR) & Request To Send (RTS) output signals are connected to the +12 Volt power supply (through a resistor) and are always asserted when the FS-03 power is on.

PIN # 1 = Not Used

PIN # 2 = Receive Data (RxD) Input

PIN # 3 = Transmit Data (TxD) Output

PIN # 4 = Data Terminal Ready (DTR) Output

PIN # 5 = Ground

PIN # 6 = Not Used

PIN # 7 = Request to Send (RTS) Output

PIN # 8 = Not Used

PIN # 9 = Not Used





The FS-03 only requires receive data (pin 2), transmit data (pin 3), and signal ground (pin 5) to be connected for successful data communications A crossover serial cable is required (see cable diagram below).




The FS-03 is programmed for the following serial commands:

Command

Function

B

Recall preset 1

C

Recall preset 2

D

Recall preset 3

E

Recall preset 4

F

Recall preset 5

G

Recall preset 6

H

Recall preset 7

I

Recall preset 8

J-Q

Reserved for custom functions

R

Mute channel 1

S

Un-mute channel 1

T

Mute channel 2

U

Un-mute channel 2

V

Mute Channel 3

W

Un-mute channel 3

X

Mute Channel 4

Y

Un-mute channel 4

Z

Mute Channel 5

b

Un-mute Channel 5

c

Mute channel 6

d

Un-mute channel 6

e

Mute channel 7

f

Un-mute channel 7

g

Mute channel 8

h

Un-mute channel 8

i

Mute channels 1-8

j

Un-mute channels 1-8

RS-232 Volume Control of inputs 7&8, and AUX 1&2






Channel 7

Channel 8

AUX 1

AUX 2

Gain Structure*

-6 to +63**

-6 to +63

+6

+6

Volume Control Range

-60 to +6

-60 to +6

-60 to +6

-60 to +6

Command VOLUME UP

N

P

J

L

Command VOLUME DOWN

O

Q

K

M

Change to Telco Sources

No change

No change

No change

No change

Change to In-room Speakers

+/- in 1dB

increments



+/- in 1dB

increments



+/- in 1dB

increments



+/- in 1dB

increments



Active Presets for Vol Control***

3 & 4 only

3 & 4 only

All

All

*FS-03 software application required to adjust

**Channels 7 &8 are set to 0dB when presets 3 or 4 are selected.

***FS-03 ships with preset 1 loaded. Change preset through logic input or FS-03 application.
Serial Port Data Communications Parameters

The FS-03 communicates through the Serial Port at the factory-selected rate of 38400 bits per second, with 8 data bits, 1 stop bit, and no parity. The FS-03 utilizes a subset of the standard 7-bit ASCII character set. The eighth data bit of each character (the most significant bit) should always be 0.




Directory: wp-content -> uploads -> 2017
2017 -> Leadership ohio
2017 -> Ascension Lutheran Church Counter’s Schedule January to December 2017
2017 -> Board of directors juanita Gibbons-Delaney, mha, rn president 390 Stone Castle Pass Atlanta, ga 30331
2017 -> Military History Anniversaries 16 thru 31 January Events in History over the next 15 day period that had U. S. military involvement or impacted in some way on U. S military operations or American interests
2017 -> The Or Shalom Cemetery Community Teaching on related issues of Integral
2017 -> Ford onthult samenwerking met Amazon Alexa en introduceert nieuwe navigatiemogelijkheden van Ford sync® 3 met Applink
2017 -> Start Learn and Increase gk. Question (1) Name the term used for talking on internet with the help of text messege?
2017 -> Press release from 24. 03. 2017 From a Charleston Car to a Mafia Sedan
2017 -> Tage Participants
2017 -> Citi Chicago Debate Championship Varsity and jv previews

Download 1.82 Mb.

Share with your friends:
1   ...   9   10   11   12   13   14   15   16   17




The database is protected by copyright ©ininet.org 2024
send message

    Main page