Page 3/3 Date 05.07.2017 Size 300.35 Kb. #22540
2.4 Password change – WAPC
Test Case ID
WAPC_01
Test Name
User Change password
Date
09.01.11
Input
Enter valid input(Current password , new password and retype password)
Output
Successful password changed
Result
Passed
Failure description
-
Tester
LK and SM
Comment
Test Case ID
WAPC_02
Test Name
User Change password
Date
09.01.11
Input
Enter invalid current password and valid input( new password and retype password)
Output
Error message, “Current password did not match”
Result
Passed
Failure description
-
Tester
LK and SM
Comment
Test Case ID
WAPC_03
Test Name
User Change password
Date
09.01.11
Input
Enter valid(current password, new password) and invalid retype password
Output
Error message, “Your new password and Re-type password does not match”
Result
Passed
Failure description
-
Tester
LK and SM
Comment
Test Case ID
WAPC_04
Test Name
Administrator Change password
Date
09.01.11
Input
Enter valid input(Current password, new password and retype password)
Output
Successful password changed
Result
Passed
Failure description
-
Tester
LK and SM
Comment
Test Case ID
WAPC_05
Test Name
Administrator Change password
Date
09.01.11
Input
Enter empty current password and valid input( new password and retype password)
Output
Error message, “Please enter your current password”
Result
Passed
Failure description
-
Tester
LK and SM
Comment
Test Case ID
WAPC_06
Test Name
Administrator Change password
Date
09.01.11
Input
Enter invalid current password and valid input( new password and retype password)
Output
Error message, “Current password does not match”
Result
Passed
Failure description
-
Tester
LK and SM
Comment
Test Case ID
WAPC_07
Test Name
Administrator Change password
Date
09.01.11
Input
Enter valid(current password, new password) and invalid retype password
Output
Error message, “New password and retype password is not same ”
Result
Passed
Failure description
-
Tester
LK and SM
Comment
Administrator login – WAAL
Test Case ID
WAAL_01
Test Name
Administrator login
Date
09.01.11
Input
Entering valid input (user name and password)
Output
Administrator successfully logged in
Result
Passed
Failure description
-
Tester
LK and SM
Comment
Test Case ID
WAAL_02
Test Name
Administrator login
Date
09.01.11
Input
Entering valid input (user name) and wrong password
Output
Error message, “Login failed, Try valid user and password”
Result
Passed
Failure description
-
Tester
LK
Comment
Test Case ID
WAAL_03
Test Name
Administrator login
Date
09.01.11
Input
Entering valid input (password) and wrong user name
Output
Error message, “Login failed, Try valid user and password”
Result
Passed
Failure description
-
Tester
LK
Comment
3.Mobile Application 3.1Connecting to the VU
Test Case ID
MACUA_01
Test Name
Connecting to the VU
Date
09.01.11
Input
Start Mobile application and choose mode of connection
Output
Acknowledgement received by the Mobile application from the VU
Result
Passed
Failure description
-
Tester
MS
Comment
3.2Authorizing with the VU
Test Case ID
MAAUA_01
Test Name
Authenticating the connection between the VU and the MU
Date
09.01.11
Input
1. Start the mobile application
2. Choose the mode of connection.
3. Depending on the mode of connection opted for VU connect to the MU
4. VU recognizes the MU.
Output
Acknowledgement received by the Mobile application from the VU , and details being forwarded to the mainframe
Result
Passed
Failure description
-
Tester
MS
Comment
4.Vehicle Unit 4.1Finding Mobile Units
Test Case ID
VUFMU_01
Test Name
Discovery of the mobile unit
Date
09.01.11
Input
1. Start the mobile application
2. Choose the mode of connection.
3. Depending on the mode of connection opted for VU connect to the MU
4. VU recognizes the MU
Output
Acknowledgement received by the Mobile application from the VU, and details being forwarded to the mainframe
Result
Passed
Failure description
-
Tester
MS
Comment
4.2Connect with mobile units
Test Case ID
VUCMU_01
Test Name
Establish a connection between the VU and MU
Date
09.01.11
Input
1. Start event of discovering mobile units in the range
2. Repeat doing so until a stipulated time frame
3. Shortlist the MU that are registered in the system
4. Establish a connection with the MU on this list
5. Once ensured about the existence of the MU in the range
6. Establish connection with the
Output
The MU on the list receives an acknowledgement
Result
Passed
Failure description
-
Tester
MS
Comment
Test Case ID
VUCMF_01
Test Name
Establish a connection between VU and mainframe
Date
09.01.11
Input
All the response and request to the mainframe from the VU will be tested
Output
Acknowledgement from the mainframe will be received when data is obtained successfully
Result
Passed
Failure description
-
Tester
VS, MS
Comment
5.Responsibilities 5.1Developers
Each module is tested by the developer.
5.2Software
Our system EzFare team performed manual test to approve correct functionality of the system. However for running the application following are software requirements
Java Android
Eclipse (Vice write version)
Visual Studio 2010 (.NET 4.0 framework)
SQLServer 2008
Python
6.Approvals
Name
Title
Date
yyyy-mm-dd
Signature
Share with your friends:
The database is protected by copyright ©ininet.org 2024
send message